Find equipmentComparePartsManufacturersTechnologiesIndustriesApplicationsAsset trackingMy equipmentTalk to a specialist

Data coverage & sources

The stored record for Gast R93150A: specifications, configurations, documents, sources, and gaps.

One model, connected records

Gast → R93150A → R93150A

Manufacturer model: R93150A · OEM article / order number: Not collected · Equipment type: vacuum pump

Technology: Regenerative / Side Channel

Related applications: Material Handling, Pick + Place, Pneumatic Conveying, Vacuum Hold-Down
Related industries: Printing, Pulp + Paper, Woodworking + CNC

These are technology associations. Check the operating point and process requirements to establish suitability for this model.

Compare coverage across this family

Specifications and evidence

27 stored observations · 14 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.

The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.

Pumping speed · Sourced · 4 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
600 cfm1019.406 m3/h50 Hz · model
50 Hz; [cfm]
unspecified
Source · OEM_SOURCE
different frequency
Open Flow [cfm]: 600
Retrieved 2026-10-05
680 cfm1155.327 m3/h60 Hz · model
60 Hz; [cfm]
unspecified
Source · OEM_SOURCE
Open Flow [cfm]: 680
Retrieved 2026-10-05
16990 lpm1019.4 m3/h50 Hz · model
50 Hz; [lpm]
unspecified
Source · OEM_SOURCE
different frequency
Open Flow [lpm]: 16990
Retrieved 2026-10-05
19255 lpm1155.3 m3/h60 Hz · model
60 Hz; [lpm]
unspecified
Source · OEM_SOURCE
Open Flow [lpm]: 19255
Retrieved 2026-10-05
Ultimate pressure · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Motor power · Sourced · 1 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
15 — Frequency not stated · model
Conditions not stated
unspecified
Source · OEM_SOURCE
HP: 15
Retrieved 2026-10-05
Speed · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Noise level · Sourced · 1 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
90 DBA90 dB(A)Frequency not stated · model
[DBA]
unspecified
Source · OEM_SOURCE
Sound Level [DBA]: 90
Retrieved 2026-10-05
Weight · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
452 lb205.0236 kgFrequency not stated · model
[lb]
unspecified
Source · OEM_SOURCE
Weight [lb]: 452
Retrieved 2026-10-05
205 kg205 kgFrequency not stated · model
[kg]
unspecified
Source · OEM_SOURCE
Weight [kg]: 205
Retrieved 2026-10-05
Dimensions · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
26.24 L x 20.7 W x 22.71 H L x 20.7 W x 22.71 H in— Frequency not stated · model
[in]
unspecified
Source · OEM_SOURCE
Dimensions [in]: 26.24 L x 20.7 W x 22.71 H
Retrieved 2026-10-05
666.5 L x 525.8 W x 576.8 H L x 525.8 W x 576.8 H mm— Frequency not stated · model
[mm]
unspecified
Source · OEM_SOURCE
Dimensions [mm]: 666.5 L x 525.8 W x 576.8 H
Retrieved 2026-10-05
Inlet connection · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Outlet connection · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Amps · Needs review · 2 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
40/20 /20— 50 Hz · model
50 Hz
unspecified
Source · OEM_SOURCE
different frequency
Amps: 40/20
Retrieved 2026-10-05
45/22.5 /22.5— 60 Hz · model
60 Hz
unspecified
Source · OEM_SOURCE
Amps: 45/22.5
Retrieved 2026-10-05
Coo · Needs review · 1 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
US — Frequency not stated · model
Conditions not stated
unspecified
Source · OEM_SOURCE
COO: US
Retrieved 2026-10-05
Flow at max. pressure · Sourced · 8 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
250 cfm424.7525 m3/h50 Hz · model
50 Hz; Pressure [cfm]
unspecified
Source · OEM_SOURCE
different frequency
Flow @ Max Pressure [cfm]: 250
Retrieved 2026-10-05
480 cfm815.5248 m3/h60 Hz · model
60 Hz; Pressure [cfm]
unspecified
Source · OEM_SOURCE
Flow @ Max Pressure [cfm]: 480
Retrieved 2026-10-05
7079.2 lpm424.752 m3/h50 Hz · model
50 Hz; Pressure [lpm]
unspecified
Source · OEM_SOURCE
different frequency
Flow @ Max Pressure [lpm]: 7079.2
Retrieved 2026-10-05
13592.1 lpm815.526 m3/h60 Hz · model
60 Hz; Pressure [lpm]
unspecified
Source · OEM_SOURCE
Flow @ Max Pressure [lpm]: 13592.1
Retrieved 2026-10-05
130 cfm220.8713 m3/h50 Hz · model
50 Hz; Vac [cfm]
unspecified
Source · OEM_SOURCE
different frequency
Flow @ Max Vac [cfm]: 130
Retrieved 2026-10-05
280 cfm475.7228 m3/h60 Hz · model
60 Hz; Vac [cfm]
unspecified
Source · OEM_SOURCE
Flow @ Max Vac [cfm]: 280
Retrieved 2026-10-05
3681.2 lpm220.872 m3/h50 Hz · model
50 Hz; Vac [lpm]
unspecified
Source · OEM_SOURCE
different frequency
Flow @ Max Vac [lpm]: 3681.2
Retrieved 2026-10-05
7928.7 lpm475.722 m3/h60 Hz · model
60 Hz; Vac [lpm]
unspecified
Source · OEM_SOURCE
Flow @ Max Vac [lpm]: 7928.7
Retrieved 2026-10-05
Max. pressure · Sourced · 1 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
N/A psi— Frequency not stated · model
[psi]
unspecified
Source · OEM_SOURCE
Max Pressure [psi]: N/A
Retrieved 2026-10-05
Max. vacuum · Sourced · 1 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
N/A in hg— Frequency not stated · model
[in hg]
unspecified
Source · OEM_SOURCE
Max Vacuum [in hg]: N/A
Retrieved 2026-10-05
Phase · Needs review · 1 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
Three Phase — Frequency not stated · model
Conditions not stated
unspecified
Source · OEM_SOURCE
Phase: Three Phase
Retrieved 2026-10-05
Regulatory · Needs review · 1 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
N/A — Frequency not stated · model
Conditions not stated
unspecified
Source · OEM_SOURCE
Regulatory: N/A
Retrieved 2026-10-05
Voltage · Needs review · 2 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
190-220/380-415 /380-415— 50 Hz · range
50 Hz
unspecified
Source · OEM_SOURCE
not a model rating, different frequency
Voltage: 190-220/380-415
Retrieved 2026-10-05
230/460 /460— 60 Hz · model
60 Hz
unspecified
Source · OEM_SOURCE
Voltage: 230/460
Retrieved 2026-10-05

Operating-performance coverage

Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.

No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.

Document coverage

Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.

CategoryModel linksFamily linksPublic sources
Specifications00Not collected
Performance curves / test data00Not collected
Operation / service manuals20
Parts documentation00Not collected
Drawings / dimensions00Not collected
Product / family literature10
Other / unclassified10