Data coverage & sources
The stored record for Gast R9P3300M: specifications, configurations, documents, sources, and gaps.
One model, connected records
Gast → R9P3300M → R9P3300M
Manufacturer model: R9P3300M · OEM article / order number: Not collected · Equipment type: vacuum pump
Technology: Regenerative / Side Channel
Related applications: Material Handling, Pick + Place, Pneumatic Conveying, Vacuum Hold-Down
Related industries: Printing, Pulp + Paper, Woodworking + CNC
These are technology associations. Check the operating point and process requirements to establish suitability for this model.
Compare coverage across this familySpecifications and evidence
26 stored observations · 13 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.
The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.
Pumping speed · Sourced · 4 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 1160 cfm | 1970.852 m3/h | 50 Hz · model 50 Hz; [cfm] unspecified | Source · OEM_SOURCE different frequency Open Flow [cfm]: 1160Retrieved 2026-10-05 |
| 1350 cfm | 2293.664 m3/h | 60 Hz · model 60 Hz; [cfm] unspecified | Source · OEM_SOURCEOpen Flow [cfm]: 1350Retrieved 2026-10-05 |
| 32848 lpm | 1970.88 m3/h | 50 Hz · model 50 Hz; [lpm] unspecified | Source · OEM_SOURCE different frequency Open Flow [lpm]: 32848Retrieved 2026-10-05 |
| 38228 lpm | 2293.68 m3/h | 60 Hz · model 60 Hz; [lpm] unspecified | Source · OEM_SOURCEOpen Flow [lpm]: 38228Retrieved 2026-10-05 |
Ultimate pressure · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Motor power · Sourced · 1 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 30 | — | Frequency not stated · model Conditions not stated unspecified | Source · OEM_SOURCEHP: 30Retrieved 2026-10-05 |
Speed · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Noise level · Sourced · 1 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 90 DBA | 90 dB(A) | Frequency not stated · model [DBA] unspecified | Source · OEM_SOURCESound Level [DBA]: 90Retrieved 2026-10-05 |
Weight · Sourced · 2 observations / 1 sources
Dimensions · Sourced · 2 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 32.52 L x 20.73 W x 22.6 H L x 20.73 W x 22.6 H in | — | Frequency not stated · model [in] unspecified | Source · OEM_SOURCEDimensions [in]: 32.52 L x 20.73 W x 22.6 HRetrieved 2026-10-05 |
| 826.0 L x 526.5 W x 574.0 H L x 526.5 W x 574.0 H mm | — | Frequency not stated · model [mm] unspecified | Source · OEM_SOURCEDimensions [mm]: 826.0 L x 526.5 W x 574.0 HRetrieved 2026-10-05 |
Inlet connection · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Outlet connection · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Amps · Needs review · 2 observations / 1 sources · classification pending
Coo · Needs review · 1 observations / 1 sources · classification pending
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| US | — | Frequency not stated · model Conditions not stated unspecified | Source · OEM_SOURCECOO: USRetrieved 2026-10-05 |
Flow at max. pressure · Sourced · 8 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 640 cfm | 1087.366 m3/h | 50 Hz · model 50 Hz; Pressure [cfm] unspecified | Source · OEM_SOURCE different frequency Flow @ Max Pressure [cfm]: 640Retrieved 2026-10-05 |
| 900 cfm | 1529.109 m3/h | 60 Hz · model 60 Hz; Pressure [cfm] unspecified | Source · OEM_SOURCEFlow @ Max Pressure [cfm]: 900Retrieved 2026-10-05 |
| 18122.8 lpm | 1087.368 m3/h | 50 Hz · model 50 Hz; Pressure [lpm] unspecified | Source · OEM_SOURCE different frequency Flow @ Max Pressure [lpm]: 18122.8Retrieved 2026-10-05 |
| 25485.1 lpm | 1529.106 m3/h | 60 Hz · model 60 Hz; Pressure [lpm] unspecified | Source · OEM_SOURCEFlow @ Max Pressure [lpm]: 25485.1Retrieved 2026-10-05 |
| 360 cfm | 611.6436 m3/h | 50 Hz · model 50 Hz; Vac [cfm] unspecified | Source · OEM_SOURCE different frequency Flow @ Max Vac [cfm]: 360Retrieved 2026-10-05 |
| 540 cfm | 917.4654 m3/h | 60 Hz · model 60 Hz; Vac [cfm] unspecified | Source · OEM_SOURCEFlow @ Max Vac [cfm]: 540Retrieved 2026-10-05 |
| 10194.1 lpm | 611.646 m3/h | 50 Hz · model 50 Hz; Vac [lpm] unspecified | Source · OEM_SOURCE different frequency Flow @ Max Vac [lpm]: 10194.1Retrieved 2026-10-05 |
| 15291.1 lpm | 917.466 m3/h | 60 Hz · model 60 Hz; Vac [lpm] unspecified | Source · OEM_SOURCEFlow @ Max Vac [lpm]: 15291.1Retrieved 2026-10-05 |
Max. pressure · Sourced · 1 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 125 in. H2O | — | Frequency not stated · model as printed: "maximum continuous pressure" unspecified | Source · OEM_SOURCEThe 30 HP R9P3300M operates at 190-220/380-415V AC with maximum continuous pressure of 125 in. H2O and air flow of 1350 CFM.Retrieved 2026-10-20 |
Phase · Needs review · 1 observations / 1 sources · classification pending
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| Three Phase | — | Frequency not stated · model Conditions not stated unspecified | Source · OEM_SOURCEPhase: Three PhaseRetrieved 2026-10-05 |
Regulatory · Needs review · 1 observations / 1 sources · classification pending
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| N/A | — | Frequency not stated · model Conditions not stated unspecified | Source · OEM_SOURCERegulatory: N/ARetrieved 2026-10-05 |
Voltage · Needs review · 2 observations / 1 sources · classification pending
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 190-220/380-415 /380-415 | — | 50 Hz · range 50 Hz unspecified | Source · OEM_SOURCE not a model rating, different frequency Voltage: 190-220/380-415Retrieved 2026-10-05 |
| 230/460 /460 | — | 60 Hz · model 60 Hz unspecified | Source · OEM_SOURCEVoltage: 230/460Retrieved 2026-10-05 |
Operating-performance coverage
Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.
No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.
Document coverage
Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.
| Category | Model links | Family links | Public sources |
|---|---|---|---|
| Specifications | 0 | 0 | Not collected |
| Performance curves / test data | 0 | 0 | Not collected |
| Operation / service manuals | 2 | 0 |
|
| Parts documentation | 0 | 0 | Not collected |
| Drawings / dimensions | 0 | 0 | Not collected |
| Product / family literature | 1 | 0 |
|
| Other / unclassified | 1 | 0 |