Hoffman & Lamson → Hoffman & Lamson REVOLUTIONPLUS High-Speed Turbo Blowers → REVOLUTIONPLUS 125Hp

Manufacturer model: REVOLUTIONPLUS 125Hp · OEM article / order number: Not collected · Equipment type: blower

Technology: Blowers

Related applications: Aeration, Pneumatic Conveying, Pressure Conveying
Related industries: Mining, Pulp + Paper, Water + Wastewater

These are technology associations. Check the operating point and process requirements to establish suitability for this model.

Compare coverage across this family

Specifications and evidence

15 stored observations · 15 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.

The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.

Blower flow · Sourced · 7 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
85 m³/min5100 m3/hFrequency not stated · model
at 6,000 mmAq outlet pressure
unspecified
Source · OEM_SOURCE
Air Flow: 85
Retrieved 2026-10-05
72 m³/min4320 m3/hFrequency not stated · model
at 7,000 mmAq outlet pressure
unspecified
Source · OEM_SOURCE
Air Flow: 72
Retrieved 2026-10-05
67 m³/min4020 m3/hFrequency not stated · model
at 8,000 mmAq outlet pressure
unspecified
Source · OEM_SOURCE
Air Flow: 67
Retrieved 2026-10-05
60 m³/min3600 m3/hFrequency not stated · model
at 9,000 mmAq outlet pressure
unspecified
Source · OEM_SOURCE
Air Flow: 60
Retrieved 2026-10-05
55 m³/min3300 m3/hFrequency not stated · model
at 10,000 mmAq outlet pressure
unspecified
Source · OEM_SOURCE
Air Flow: 55
Retrieved 2026-10-05
50 m³/min3000 m3/hFrequency not stated · model
at 11,000 mmAq outlet pressure
unspecified
Source · OEM_SOURCE
Air Flow: 50
Retrieved 2026-10-05
45 m³/min2700 m3/hFrequency not stated · model
at 12,000 mmAq outlet pressure
unspecified
Source · OEM_SOURCE
Air Flow: 45
Retrieved 2026-10-05
Max. pressure · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Max. vacuum · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Motor power · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Speed · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Noise level · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Weight · Sourced · 1 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
790 kg790 kgFrequency not stated · model
Conditions not stated
unspecified
Source · OEM_SOURCE
Weight: 790
Retrieved 2026-10-05
Dimensions · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Inlet connection · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Outlet connection · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Reference working pressure · Sourced · 7 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
9,000 mmAq882.5985 mbarFrequency not stated · model
outlet pressure; the pressure "Air Flow" is stated at (at 9,000 mmAq outlet pressure)
unspecified
Source · OEM_SOURCE
Air Flow: 60
Retrieved 2026-10-20
12,000 mmAq1176.798 mbarFrequency not stated · model
outlet pressure; the pressure "Air Flow" is stated at (at 12,000 mmAq outlet pressure)
unspecified
Source · OEM_SOURCE
Air Flow: 45
Retrieved 2026-10-20
11,000 mmAq1078.732 mbarFrequency not stated · model
outlet pressure; the pressure "Air Flow" is stated at (at 11,000 mmAq outlet pressure)
unspecified
Source · OEM_SOURCE
Air Flow: 50
Retrieved 2026-10-20
6,000 mmAq588.399 mbarFrequency not stated · model
outlet pressure; the pressure "Air Flow" is stated at (at 6,000 mmAq outlet pressure)
unspecified
Source · OEM_SOURCE
Air Flow: 85
Retrieved 2026-10-20
7,000 mmAq686.4655 mbarFrequency not stated · model
outlet pressure; the pressure "Air Flow" is stated at (at 7,000 mmAq outlet pressure)
unspecified
Source · OEM_SOURCE
Air Flow: 72
Retrieved 2026-10-20
10,000 mmAq980.665 mbarFrequency not stated · model
outlet pressure; the pressure "Air Flow" is stated at (at 10,000 mmAq outlet pressure)
unspecified
Source · OEM_SOURCE
Air Flow: 55
Retrieved 2026-10-20
8,000 mmAq784.532 mbarFrequency not stated · model
outlet pressure; the pressure "Air Flow" is stated at (at 8,000 mmAq outlet pressure)
unspecified
Source · OEM_SOURCE
Air Flow: 67
Retrieved 2026-10-20

Operating-performance coverage

Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.

No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.

Document coverage

Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.

CategoryModel linksFamily linksPublic sources
Specifications10
Performance curves / test data00Not collected
Operation / service manuals00Not collected
Parts documentation00Not collected
Drawings / dimensions00Not collected
Product / family literature10
Other / unclassified00Not collected