Data coverage & sources
The stored record for Leybold DRYVAC DV 650 FP-r: specifications, configurations, documents, sources, and gaps.
One model, connected records
Leybold → DRYVAC FP-r Dry screw pumps for food processing → DRYVAC DV 650 FP-r
Manufacturer model: DRYVAC DV 650 FP-r · OEM article / order number: Not collected · Equipment type: vacuum pump
Technology: Dry Screw
Related applications: Degassing, Drying, Process Vacuum
Related industries: Chemical, Oil + Gas, Pharmaceutical, Semiconductor
These are technology associations. Check the operating point and process requirements to establish suitability for this model.
Compare coverage across this familySpecifications and evidence
15 stored observations · 12 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.
The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.
Pumping speed · Sourced · 1 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 650 m3/h | 650 m3/h | Frequency not stated · model Conditions not stated unspecified | Source · OEM_SOURCEMaximum pumping speed: 650Retrieved 2026-10-01 |
Ultimate pressure · Sourced · 2 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| < 0,005 mbar | 0.005 mbar | Frequency not stated · model without Gas ballast unspecified | Source · OEM_SOURCEUltimate pressure without Gas ballast: < 0,005Retrieved 2026-10-01 |
| 0,01 mbar | 0.01 mbar | Frequency not stated · model with Gas ballast unspecified | Source · OEM_SOURCEUltimate pressure with Gas ballast: 0,01Retrieved 2026-10-01 |
Motor power · Sourced · 1 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 15 kW | 15 kW | Frequency not stated · model Conditions not stated unspecified | Source · OEM_SOURCERated power: 15Retrieved 2026-10-01 |
Speed · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Noise level · Sourced · 1 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 70 dB(A) | 70 dB(A) | Frequency not stated · model with stainless silencer open to the room, at ultimate pressure (according to DIN EN ISO 21 51) unspecified | Source · OEM_SOURCENoise level with stainless silencer open to the room, at ultimate pressure (according to DIN EN ISO 21 51): 70Retrieved 2026-10-01 |
Weight · Sourced · 2 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 560 kg | 560 kg | Frequency not stated · model approximate unspecified | Source · OEM_SOURCEWeight, approximate: 560Retrieved 2026-10-01 |
| 600 kg | 600 kg | Frequency not stated · model approximate(with silencer) unspecified | Source · OEM_SOURCEWeight, approximate(with silencer): 600Retrieved 2026-10-01 |
Dimensions · Sourced · 2 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 1211 x 450 x 400 mm | — | Frequency not stated · model (L x W x H) unspecified | Source · OEM_SOURCEDimensions (L x W x H): 1211 x 450 x 400Retrieved 2026-10-01 |
| 1211 x 580 x 570 mm | — | Frequency not stated · model with silencer (L x W x H) unspecified | Source · OEM_SOURCEDimensions with silencer (L x W x H): 1211 x 580 x 570Retrieved 2026-10-01 |
Inlet connection · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Outlet connection · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Bearing Lubricant Filling · Needs review · 1 observations / 1 sources · classification pending
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 1,2 l | 1.2 l | Frequency not stated · model Conditions not stated unspecified | Source · OEM_SOURCEBearing lubricant filling: 1,2Retrieved 2026-10-01 |
Exhaust Flange · Needs review · 1 observations / 1 sources · classification pending
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| DN 63 ISO-K (Pumps with silencer: Pipe diameter 88,9 mm) | — | Frequency not stated · model Conditions not stated unspecified | Source · OEM_SOURCEExhaust flange: DN 63 ISO-K (Pumps with silencer: Pipe diameter 88,9 mm)Retrieved 2026-10-01 |
Intake Flange · Needs review · 1 observations / 1 sources · classification pending
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| DN 100 ISO-K (1 on top, 2 on the sides) | — | Frequency not stated · model Conditions not stated unspecified | Source · OEM_SOURCEIntake flange: DN 100 ISO-K (1 on top, 2 on the sides)Retrieved 2026-10-01 |
Power consumption · Sourced · 1 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 6.6 kW | 6.6 kW | Frequency not stated · model < 10 mbar unspecified | Source · OEM_SOURCEPower consumption < 10 mbar: 6.6Retrieved 2026-10-01 |
Water vapour tolerance · Sourced · 2 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 60 mbar | 60 mbar | Frequency not stated · model with exhaust shaft seal purge gas unspecified | Source · OEM_SOURCEWater vapour tolerance with exhaust shaft seal purge gas: 60Retrieved 2026-10-01 |
| 25 kg/h | 25 kg/h | Frequency not stated · model Conditions not stated unspecified | Source · OEM_SOURCEWater vapour capacity: 25Retrieved 2026-10-01 |
Operating-performance coverage
Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.
No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.
Document coverage
Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.
| Category | Model links | Family links | Public sources |
|---|---|---|---|
| Specifications | 0 | 0 | Not collected |
| Performance curves / test data | 0 | 0 | Not collected |
| Operation / service manuals | 0 | 0 | Not collected |
| Parts documentation | 0 | 0 | Not collected |
| Drawings / dimensions | 0 | 0 | Not collected |
| Product / family literature | 2 | 0 |
|
| Other / unclassified | 0 | 0 | Not collected |