Find equipmentComparePartsManufacturersTechnologiesIndustriesApplicationsAsset trackingMy equipmentTalk to a specialist

Data coverage & sources

The stored record for Leybold NOVADRY ND 400i System: specifications, configurations, documents, sources, and gaps.

One model, connected records

Leybold → NOVADRY NDi System Smart NOVADRY-based central vacuum system → NOVADRY ND 400i System

Manufacturer model: NOVADRY ND 400i System · OEM article / order number: Not collected · Equipment type: vacuum pump

Technology: Dry Screw

Related applications: Degassing, Drying, Process Vacuum
Related industries: Chemical, Oil + Gas, Pharmaceutical, Semiconductor

These are technology associations. Check the operating point and process requirements to establish suitability for this model.

Compare coverage across this family

Specifications and evidence

10 stored observations · 8 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.

The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.

Pumping speed · Sourced · 1 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
400 m³/h400 m3/hFrequency not stated · model
(w/o gas ballast)
unspecified
Source · OEM_SOURCE
Maximum pumping speed (w/o gas ballast): 400
Retrieved 2026-10-01
Ultimate pressure · Sourced · 1 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
5 mbar5 mbarFrequency not stated · model
w/o gas ballast
unspecified
Source · OEM_SOURCE
Ultimate pressure w/o gas ballast: 5
Retrieved 2026-10-01
Motor power · Sourced · 1 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
9 kW9 kWFrequency not stated · model
60 Hz; 50Hz / 60Hz
unspecified
Source · OEM_SOURCE
Nominal motor power 50Hz / 60Hz: 9
Retrieved 2026-10-01
Speed · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Noise level · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Weight · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Dimensions · Sourced · 1 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
1410 x 925 x 1503 mm— Frequency not stated · model
(L x W H)
unspecified
Source · OEM_SOURCE
Dimensions (L x W H): 1410 x 925 x 1503
Retrieved 2026-10-01
Inlet connection · Sourced · 1 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
DN80 / DN80 — Frequency not stated · model
/ outlet connection
unspecified
Source · OEM_SOURCE
Inlet / outlet connection: DN80 / DN80
Retrieved 2026-10-01
Outlet connection · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Ambient temperature · Sourced · 1 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
0 to +40 °C to +40 °C °C— Frequency not stated · model
temperature
unspecified
Source · OEM_SOURCE
Permissible ambient temperature: 0 to +40 °C
Retrieved 2026-10-01
Max Permissible Inlet Pressure · Needs review · 1 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
1200 mbar1200 mbarFrequency not stated · model
Conditions not stated
unspecified
Source · OEM_SOURCE
Max. permissible inlet pressure: 1200
Retrieved 2026-10-01
Max Permissible Outlet Pressure Rel To Ambient · Needs review · 1 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
200 mbar200 mbarFrequency not stated · model
Conditions not stated
unspecified
Source · OEM_SOURCE
Max. permissible outlet pressure (rel. to ambient): 200
Retrieved 2026-10-01
Water vapour tolerance · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
60 mbar60 mbarFrequency not stated · model
with gas ballast
unspecified
Source · OEM_SOURCE
Water vapor tolerance with gas ballast: 60
Retrieved 2026-10-01
13,8 kg/h13.8 kg/hFrequency not stated · model
with gas ballast
unspecified
Source · OEM_SOURCE
Water vapor capacity with gas ballast: 13,8
Retrieved 2026-10-01

Operating-performance coverage

Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.

No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.

Document coverage

Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.

CategoryModel linksFamily linksPublic sources
Specifications00Not collected
Performance curves / test data00Not collected
Operation / service manuals00Not collected
Parts documentation00Not collected
Drawings / dimensions00Not collected
Product / family literature10