Find equipmentComparePartsManufacturersTechnologiesIndustriesApplicationsAsset trackingMy equipmentTalk to a specialist

Data coverage & sources

The stored record for Osaka Vacuum TGkine 2200MI-B: specifications, configurations, documents, sources, and gaps.

One model, connected records

Osaka Vacuum → Osaka Vacuum TGkine 2200MI-B / TGkine 3300MI-B / TGkine 3400MI-B / TGkine 3800MI-B / TGkine 4200MI-B → TGkine 2200MI-B

Manufacturer model: TGkine 2200MI-B · OEM article / order number: Not collected · Equipment type: vacuum pump

Technology: Turbomolecular

Compare coverage across this family

Specifications and evidence

11 stored observations · 5 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.

The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.

Pumping speed · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
2200 L/s7920 m3/hFrequency not stated · model
N₂; rate
unspecified
Source · OEM_SOURCE
Volume flow rate: 2200
Retrieved 2026-10-03
2100 L/s7560 m3/hFrequency not stated · model
N₂(with protective screen); rate
unspecified
Source · OEM_SOURCE
Volume flow rate: 2100
Retrieved 2026-10-03
1800 L/s6480 m3/hFrequency not stated · model
H₂; rate
unspecified
Source · OEM_SOURCE
Volume flow rate: 1800
Retrieved 2026-10-03
Ultimate pressure · Sourced · 1 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
<2×10⁻⁷ Pa— Frequency not stated · model
as printed: "Base pressure"; <1.5×10⁻⁹ Torr
unspecified
Source · OEM_SOURCE
Base pressure | Pa | <2×10⁻⁷ | <2×10⁻⁷ | <2×10⁻⁷ | <5×10⁻⁷ | <5×10⁻⁷
Retrieved 2026-10-20
Motor power · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Speed · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Noise level · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Weight · Sourced · 1 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
65 kg65 kgFrequency not stated · model
Conditions not stated
unspecified
Source · OEM_SOURCE
Weight: 65
Retrieved 2026-10-03
Dimensions · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Inlet connection · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Outlet connection · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Max. backing pressure · Needs review · 1 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
100 Pa1 mbarFrequency not stated · model
Conditions not stated
unspecified
Source · OEM_SOURCE
Max. backing pressure: 100
Retrieved 2026-10-03
Max. throughput · Needs review · 2 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
5000 sccm— Frequency not stated · model
N₂
unspecified
Source · OEM_SOURCE
Max. throughput: 5000
Retrieved 2026-10-03
3000 sccm— Frequency not stated · model
Ar
unspecified
Source · OEM_SOURCE
Max. throughput: 3000
Retrieved 2026-10-03
Recommended backing pump · Needs review · 1 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
≥2000 L/min120 m3/hFrequency not stated · model
Conditions not stated
unspecified
Source · OEM_SOURCE
Recommended backing pump: ≥2000
Retrieved 2026-10-03
Shutdown time · Needs review · 1 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
≤10 min— Frequency not stated · model
Conditions not stated
unspecified
Source · OEM_SOURCE
Shutdown time: ≤10
Retrieved 2026-10-03
Startup time · Needs review · 1 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
≤10 min— Frequency not stated · model
Conditions not stated
unspecified
Source · OEM_SOURCE
Startup time: ≤10
Retrieved 2026-10-03

Operating-performance coverage

Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.

No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.

Document coverage

Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.

CategoryModel linksFamily linksPublic sources
Specifications00Not collected
Performance curves / test data00Not collected
Operation / service manuals00Not collected
Parts documentation00Not collected
Drawings / dimensions00Not collected
Product / family literature00Not collected
Other / unclassified00Not collected