Data coverage & sources
The stored record for Pfeiffer Vacuum+Fab Solutions COMBI RU 1102: specifications, configurations, documents, sources, and gaps.
One model, connected records
Pfeiffer Vacuum+Fab Solutions → COMBI RU → COMBI RU 1102
Manufacturer model: COMBI RU 1102 · OEM article / order number: Not collected · Equipment type: system
Technology: Central Vacuum Systems
Related applications: Central Vacuum, CNC Routing, Medical Suction, Packaging
Related industries: Medical, Packaging
These are technology associations. Check the operating point and process requirements to establish suitability for this model.
Compare coverage across this familySpecifications and evidence
21 stored observations · 6 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.
The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.
Backing Pump · Needs review · 2 observations / 1 sources · classification pending
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| R5 RA 0520 A | — | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_SOURCE different frequency Backing pump: R5 RA 0520 ARetrieved 2026-10-02 |
| R5 RA 0520 A | — | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_SOURCEBacking pump: R5 RA 0520 ARetrieved 2026-10-02 |
Inlet connection · Sourced · 2 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| DN 100 ISO-F/PN 16 | — | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_SOURCE different frequency Gas inlet: DN 100 ISO-F/PN 16Retrieved 2026-10-02 |
| DN 100 ISO-F/PN 16 | — | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_SOURCEGas inlet: DN 100 ISO-F/PN 16Retrieved 2026-10-02 |
Input Voltage · Needs review · 2 observations / 1 sources · classification pending
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 400 V AC (±10%), 50 Hz V AC (±10%), 50 Hz | — | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_VERIFIED different frequency Input voltage: 400 V AC (±10%), 50 HzRetrieved 2026-10-02 |
| 400 V AC (±10%), 50 Hz V AC (±10%), 50 Hz | — | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_VERIFIEDInput voltage: 400 V AC (±10%), 50 HzRetrieved 2026-10-02 |
Max Power Consumption · Needs review · 2 observations / 1 sources · classification pending
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 16 kW kW | 16 kW | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_VERIFIED different frequency Max. power consumption: 16 kWRetrieved 2026-10-02 |
| 16 kW kW | 16 kW | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_VERIFIEDMax. power consumption: 16 kWRetrieved 2026-10-02 |
Noise level · Sourced · 2 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| ≤85 dB(A) dB(A) | 85 dB(A) | 50 Hz · model ISO 50 Hz; (ISO 2151) at 1 hPa(mbar) unspecified | Source · OEM_VERIFIED different frequency Noise level (ISO 2151) at 1 hPa(mbar): ≤85 dB(A)Retrieved 2026-10-02 |
| ≤85 dB(A) dB(A) | 85 dB(A) | 60 Hz · model ISO 60 Hz; (ISO 2151) at 1 hPa(mbar) unspecified | Source · OEM_VERIFIEDNoise level (ISO 2151) at 1 hPa(mbar): ≤85 dB(A)Retrieved 2026-10-02 |
Outlet connection · Sourced · 2 observations / 1 sources
Pumping speed · Other conditions · 1 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 1106 m³/h m³/h | 1106 m3/h | 50 Hz · model ISO 50 Hz; at 1 hPa(mbar) unspecified | Source · OEM_SOURCE different frequency Pumping speed at 1 hPa(mbar): 1106 m³/hRetrieved 2026-10-02 |
Ultimate pressure · Sourced · 4 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 5 · 10⁻³ hPa (mbar) hPa (mbar) | 0.005 mbar | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_SOURCE different frequency Ultimate pressure: 5 · 10⁻³ hPa (mbar)Retrieved 2026-10-02 |
| 1 · 10⁻² hPa (mbar) hPa (mbar) | 0.01 mbar | 50 Hz · model ISO 50 Hz; with gas ballast valve unspecified | Source · OEM_VERIFIED different frequency Ultimate pressure with gas ballast valve: 1 · 10⁻² hPa (mbar)Retrieved 2026-10-02 |
| 5 · 10⁻³ hPa (mbar) hPa (mbar) | 0.005 mbar | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_SOURCEUltimate pressure: 5 · 10⁻³ hPa (mbar)Retrieved 2026-10-02 |
| 1 · 10⁻² hPa (mbar) hPa (mbar) | 0.01 mbar | 60 Hz · model ISO 60 Hz; with gas ballast valve unspecified | Source · OEM_VERIFIEDUltimate pressure with gas ballast valve: 1 · 10⁻² hPa (mbar)Retrieved 2026-10-02 |
Vacuum Booster · Needs review · 2 observations / 1 sources · classification pending
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| HiLobe 1302 | — | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_SOURCE different frequency Vacuum booster: HiLobe 1302Retrieved 2026-10-02 |
| HiLobe 1302 | — | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_SOURCEVacuum booster: HiLobe 1302Retrieved 2026-10-02 |
Weight · Sourced · 2 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 850 kg kg | 850 kg | 50 Hz · model ISO 50 Hz; approx. unspecified | Source · OEM_VERIFIED different frequency Weight approx.: 850 kgRetrieved 2026-10-02 |
| 850 kg kg | 850 kg | 60 Hz · model ISO 60 Hz; approx. unspecified | Source · OEM_VERIFIEDWeight approx.: 850 kgRetrieved 2026-10-02 |
Operating-performance coverage
Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.
No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.
Document coverage
Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.
| Category | Model links | Family links | Public sources |
|---|---|---|---|
| Specifications | 1 | 0 |
|
| Performance curves / test data | 0 | 0 | Not collected |
| Operation / service manuals | 1 | 0 |
|
| Parts documentation | 0 | 0 | Not collected |
| Drawings / dimensions | 0 | 0 | Not collected |
| Product / family literature | 0 | 0 | Not collected |
| Other / unclassified | 0 | 0 | Not collected |