Data coverage & sources
The stored record for Pfeiffer Vacuum+Fab Solutions COMBI WVD 0245: specifications, configurations, documents, sources, and gaps.
One model, connected records
Pfeiffer Vacuum+Fab Solutions → COMBI WVD → COMBI WVD 0245
Manufacturer model: COMBI WVD 0245 · OEM article / order number: Not collected · Equipment type: system
Technology: Central Vacuum Systems
Related applications: Central Vacuum, CNC Routing, Medical Suction, Packaging
Related industries: Medical, Packaging
These are technology associations. Check the operating point and process requirements to establish suitability for this model.
Compare coverage across this familySpecifications and evidence
20 stored observations · 6 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.
The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.
Backing Pump · Needs review · 2 observations / 1 sources · classification pending
Inlet connection · Sourced · 2 observations / 1 sources
Input Voltage · Needs review · 2 observations / 1 sources · classification pending
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 400 V AC (±10 %), 50 Hz | 460 V AC (±10 %), 60 Hz V AC (±10 %), 50 Hz | 460 V AC (±10 %), 60 Hz | — | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_SOURCE different frequency Input voltage: 400 V AC (±10 %), 50 Hz | 460 V AC (±10 %), 60 HzRetrieved 2026-10-02 |
| 400 V AC (±10 %), 50 Hz | 460 V AC (±10 %), 60 Hz V AC (±10 %), 50 Hz | 460 V AC (±10 %), 60 Hz | — | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_SOURCEInput voltage: 400 V AC (±10 %), 50 Hz | 460 V AC (±10 %), 60 HzRetrieved 2026-10-02 |
Max Power Consumption · Needs review · 2 observations / 1 sources · classification pending
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 1.15 kW kW | 1.15 kW | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_VERIFIED different frequency Max. power consumption: 1.15 kWRetrieved 2026-10-02 |
| 1.15 kW kW | 1.15 kW | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_VERIFIEDMax. power consumption: 1.15 kWRetrieved 2026-10-02 |
Outlet connection · Sourced · 2 observations / 1 sources
Pumping speed · Sourced · 2 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 234 m³/h m³/h | 234 m3/h | 50 Hz · model ISO 50 Hz; at 1 hPa(mbar) unspecified | Source · OEM_SOURCE different frequency Pumping speed at 1 hPa(mbar): 234 m³/hRetrieved 2026-10-02 |
| 284 m³/h m³/h | 284 m3/h | 60 Hz · model ISO 60 Hz; at 1 hPa(mbar) unspecified | Source · OEM_VERIFIEDPumping speed at 1 hPa(mbar): 284 m³/hRetrieved 2026-10-02 |
Ultimate pressure · Sourced · 4 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 1.7 · 10⁻³ hPa (mbar) hPa (mbar) | 0.0017 mbar | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_VERIFIED different frequency Ultimate pressure: 1.7 · 10⁻³ hPa (mbar)Retrieved 2026-10-02 |
| 2 · 10⁻³ hPa (mbar) hPa (mbar) | 0.002 mbar | 50 Hz · model ISO 50 Hz; with gas ballast valve unspecified | Source · OEM_VERIFIED different frequency Ultimate pressure with gas ballast valve: 2 · 10⁻³ hPa (mbar)Retrieved 2026-10-02 |
| 1.7 · 10⁻³ hPa (mbar) hPa (mbar) | 0.0017 mbar | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_VERIFIEDUltimate pressure: 1.7 · 10⁻³ hPa (mbar)Retrieved 2026-10-02 |
| 2 · 10⁻³ hPa (mbar) hPa (mbar) | 0.002 mbar | 60 Hz · model ISO 60 Hz; with gas ballast valve unspecified | Source · OEM_VERIFIEDUltimate pressure with gas ballast valve: 2 · 10⁻³ hPa (mbar)Retrieved 2026-10-02 |
Vacuum Booster · Needs review · 2 observations / 1 sources · classification pending
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| PANDA WV 0250 C | — | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_SOURCE different frequency Vacuum booster: PANDA WV 0250 CRetrieved 2026-10-02 |
| PANDA WV 0250 C | — | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_SOURCEVacuum booster: PANDA WV 0250 CRetrieved 2026-10-02 |
Weight · Sourced · 2 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 575 kg kg | 575 kg | 50 Hz · model ISO 50 Hz; approx. unspecified | Source · OEM_VERIFIED different frequency Weight approx.: 575 kgRetrieved 2026-10-02 |
| 575 kg kg | 575 kg | 60 Hz · model ISO 60 Hz; approx. unspecified | Source · OEM_VERIFIEDWeight approx.: 575 kgRetrieved 2026-10-02 |
Operating-performance coverage
Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.
No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.
Document coverage
Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.
| Category | Model links | Family links | Public sources |
|---|---|---|---|
| Specifications | 1 | 0 |
|
| Performance curves / test data | 0 | 0 | Not collected |
| Operation / service manuals | 1 | 0 |
|
| Parts documentation | 0 | 0 | Not collected |
| Drawings / dimensions | 0 | 0 | Not collected |
| Product / family literature | 0 | 0 | Not collected |