Find equipmentComparePartsManufacturersTechnologiesIndustriesApplicationsAsset trackingMy equipmentTalk to a specialist

Data coverage & sources

The stored record for Pfeiffer Vacuum+Fab Solutions DuoVane 300: specifications, configurations, documents, sources, and gaps.

One model, connected records

Pfeiffer Vacuum+Fab Solutions → DuoVane 135/300 → DuoVane 300

Manufacturer model: DuoVane 300 · OEM article / order number: Not collected · Equipment type: vacuum pump

Technology: Oil-Lubricated Rotary Vane

Related applications: Central Vacuum, Degassing, Drying, Leak Testing, Medical Suction, Packaging, Vacuum Forming
Related industries: Automotive, Food + Beverage, Medical, Metalworking, Packaging, Plastics

These are technology associations. Check the operating point and process requirements to establish suitability for this model.

Compare coverage across this family

Specifications and evidence

24 stored observations · 11 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.

The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.

Pumping speed · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
250 m³/h m³/h250 m3/h50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
different frequency
Nominal pumping speed: 250 m³/h
Retrieved 2026-10-02
300 m³/h m³/h300 m3/h60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_VERIFIED
Nominal pumping speed: 300 m³/h
Retrieved 2026-10-02
Ultimate pressure · Sourced · 4 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
3 · 10⁻³ hPa(mbar) hPa(mbar)0.003 mbar50 Hz · model
ISO 50 Hz; (gas-ballast valve closed)
unspecified
Source · OEM_VERIFIED
different frequency
Ultimate pressure (gas-ballast valve closed): 3 · 10⁻³ hPa(mbar)
Retrieved 2026-10-02
4 · 10⁻³ hPa(mbar) hPa(mbar)0.004 mbar50 Hz · model
ISO 50 Hz; (gas-ballast valve open)
unspecified
Source · OEM_VERIFIED
different frequency
Ultimate pressure (gas-ballast valve open): 4 · 10⁻³ hPa(mbar)
Retrieved 2026-10-02
3 · 10⁻³ hPa(mbar) hPa(mbar)0.003 mbar60 Hz · model
ISO 60 Hz; (gas-ballast valve closed)
unspecified
Source · OEM_VERIFIED
Ultimate pressure (gas-ballast valve closed): 3 · 10⁻³ hPa(mbar)
Retrieved 2026-10-02
4 · 10⁻³ hPa(mbar) hPa(mbar)0.004 mbar60 Hz · model
ISO 60 Hz; (gas-ballast valve open)
unspecified
Source · OEM_VERIFIED
Ultimate pressure (gas-ballast valve open): 4 · 10⁻³ hPa(mbar)
Retrieved 2026-10-02
Motor power · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
7.5 kW kW7.5 kW50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
different frequency
Nominal motor rating: 7.5 kW
Retrieved 2026-10-02
9 kW kW9 kW60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_VERIFIED
Nominal motor rating: 9 kW
Retrieved 2026-10-02
Speed · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
1000 min⁻¹ min⁻¹1000 rpm50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
different frequency
Nominal motor speed: 1000 min⁻¹
Retrieved 2026-10-02
1200 min⁻¹ min⁻¹1200 rpm60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_VERIFIED
Nominal motor speed: 1200 min⁻¹
Retrieved 2026-10-02
Noise level · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
75 dB(A) dB(A)75 dB(A)50 Hz · model
ISO 50 Hz; (50 Hz)
unspecified
Source · OEM_SOURCE
different frequency
Sound pressure level (50 Hz): 75 dB(A)
Retrieved 2026-10-02
75 dB(A) dB(A)75 dB(A)Frequency not stated · model
ISO 60 Hz; (50 Hz)
unspecified
Source · OEM_SOURCE
Sound pressure level (50 Hz): 75 dB(A)
Retrieved 2026-10-02
Weight · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
360 kg kg360 kg50 Hz · model
ISO 50 Hz; approx.
unspecified
Source · OEM_VERIFIED
different frequency
Weight approx.: 360 kg
Retrieved 2026-10-02
360 kg kg360 kg60 Hz · model
ISO 60 Hz; approx.
unspecified
Source · OEM_VERIFIED
Weight approx.: 360 kg
Retrieved 2026-10-02
Dimensions · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
1407 x 460 x 670 mm mm— 50 Hz · model
ISO 50 Hz; (L x W x H)
unspecified
Source · OEM_SOURCE
different frequency
Dimensions (L x W x H): 1407 x 460 x 670 mm
Retrieved 2026-10-02
1407 x 460 x 670 mm mm— 60 Hz · model
ISO 60 Hz; (L x W x H)
unspecified
Source · OEM_SOURCE
Dimensions (L x W x H): 1407 x 460 x 670 mm
Retrieved 2026-10-02
Inlet connection · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
DN 100 ISO-F — 50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
different frequency
Gas inlet: DN 100 ISO-F
Retrieved 2026-10-02
DN 100 ISO-F — 60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_SOURCE
Gas inlet: DN 100 ISO-F
Retrieved 2026-10-02
Outlet connection · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
DN 100 ISO-F — 50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
different frequency
Gas outlet: DN 100 ISO-F
Retrieved 2026-10-02
DN 100 ISO-F — 60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_SOURCE
Gas outlet: DN 100 ISO-F
Retrieved 2026-10-02
Motor Phase · Needs review · 2 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
Three-phase — 50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
different frequency
Motor phase: Three-phase
Retrieved 2026-10-02
Three-phase — 60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_SOURCE
Motor phase: Three-phase
Retrieved 2026-10-02
Oil capacity · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
25 l l25 l50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_VERIFIED
different frequency
Oil capacity: 25 l
Retrieved 2026-10-02
25 l l25 l60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_VERIFIED
Oil capacity: 25 l
Retrieved 2026-10-02

Operating-performance coverage

Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.

No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.

Document coverage

Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.

CategoryModel linksFamily linksPublic sources
Specifications10
Performance curves / test data00Not collected
Operation / service manuals00Not collected
Parts documentation00Not collected
Drawings / dimensions00Not collected
Product / family literature00Not collected
Other / unclassified00Not collected