Data coverage & sources
The stored record for Pfeiffer Vacuum+Fab Solutions HiLobe 6204: specifications, configurations, documents, sources, and gaps.
One model, connected records
Pfeiffer Vacuum+Fab Solutions → HiLobe 2704-6204 → HiLobe 6204
Manufacturer model: HiLobe 6204 · OEM article / order number: Not collected · Equipment type: booster
Technology: Roots / Booster
Related applications: Leak Testing, Process Vacuum
Related industries: Automotive, Chemical, Metalworking, Oil + Gas, Power Generation, Semiconductor
These are technology associations. Check the operating point and process requirements to establish suitability for this model.
Compare coverage across this familySpecifications and evidence
23 stored observations · 6 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.
The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.
Pumping speed · Needs review · 1 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 890-6220 m³/h m³/h | 890 m3/h | Frequency not stated · range ISO unspecified | Source · OEM_VERIFIED not a model rating Nominal pumping speed: 890-6220 m³/hRetrieved 2026-10-02 |
Ultimate pressure · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Motor power · Sourced · 1 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 7,5 kW kW | 7.5 kW | Frequency not stated · model ISO; at full rotational speed unspecified | Source · OEM_VERIFIEDRated power at full rotational speed: 7,5 kWRetrieved 2026-10-02 |
Speed · Needs review · 1 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 1500-10500 rpm rpm | 1500 rpm | Frequency not stated · range ISO unspecified | Source · OEM_VERIFIED not a model rating Rotational speed: 1500-10500 rpmRetrieved 2026-10-02 |
Noise level · Sourced · 1 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 65 dB(A) dB(A) | 65 dB(A) | Frequency not stated · model ISO; (EN ISO 2151) at inlet pressure 1 hPa unspecified | Source · OEM_SOURCESound pressure level (EN ISO 2151) at inlet pressure 1 hPa: 65 dB(A)Retrieved 2026-10-02 |
Weight · Sourced · 1 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 280 kg kg | 280 kg | Frequency not stated · model ISO; approx. unspecified | Source · OEM_VERIFIEDWeight approx.: 280 kgRetrieved 2026-10-02 |
Dimensions · Sourced · 1 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 1122 x 430 x 354 mm mm | — | Frequency not stated · model ISO; (L x W x H) unspecified | Source · OEM_SOURCEDimensions (L x W x H): 1122 x 430 x 354 mmRetrieved 2026-10-02 |
Inlet connection · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Outlet connection · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Ambient temperature · Needs review · 1 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 5-40 °C °C | 5 °C | Frequency not stated · range ISO unspecified | Source · OEM_VERIFIED not a model rating Ambient temperature: 5-40 °CRetrieved 2026-10-02 |
Cooling Method · Needs review · 1 observations / 1 sources · classification pending
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| Active air cooling | — | Frequency not stated · model ISO unspecified | Source · OEM_SOURCECooling method: Active air coolingRetrieved 2026-10-02 |
Electronic Drive Unit · Needs review · 1 observations / 1 sources · classification pending
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| RC 7500 | — | Frequency not stated · model ISO unspecified | Source · OEM_SOURCEElectronic drive unit: RC 7500Retrieved 2026-10-02 |
Input Voltages · Needs review · 1 observations / 1 sources · classification pending
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 380-480 AC (±10), 50/60 Hz AC AC (±10), 50/60 Hz AC | — | Frequency not stated · range ISO unspecified | Source · OEM_SOURCE not a model rating Input Voltages: 380-480 AC (±10), 50/60 Hz ACRetrieved 2026-10-02 |
Integral Leak Rate · Needs review · 1 observations / 1 sources · classification pending
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 1E-06 Pa m³/s Pa m³/s E-06 Pa m³/s Pa m³/s | — | Frequency not stated · model ISO unspecified | Source · OEM_SOURCEIntegral leak rate: 1E-06 Pa m³/s Pa m³/sRetrieved 2026-10-02 |
I O Interfaces · Needs review · 1 observations / 1 sources · classification pending
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| PV.can; RS485 | — | Frequency not stated · model ISO unspecified | Source · OEM_SOURCEI/O Interfaces: PV.can; RS485Retrieved 2026-10-02 |
Main Flange Size Type · Needs review · 1 observations / 1 sources · classification pending
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| DN 160 ISO-F | DN 150 PN 16 | — | Frequency not stated · model ISO unspecified | Source · OEM_SOURCEMain Flange Size/Type: DN 160 ISO-F | DN 150 PN 16Retrieved 2026-10-02 |
Max. vacuum · Sourced · 2 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 10 hPa hPa | 10 mbar | Frequency not stated · model ISO; at max. rotational speed unspecified | Source · OEM_SOURCEMax. differential pressure at max. rotational speed: 10 hPaRetrieved 2026-10-02 |
| 50 hPa hPa | 50 mbar | Frequency not stated · model ISO; max. at min. rotational speed unspecified | Source · OEM_SOURCEMax. differential pressure max. at min. rotational speed: 50 hPaRetrieved 2026-10-02 |
Motor Protection · Needs review · 1 observations / 1 sources · classification pending
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| PTC | — | Frequency not stated · model ISO unspecified | Source · OEM_SOURCEMotor protection: PTCRetrieved 2026-10-02 |
Motor Version · Needs review · 1 observations / 1 sources · classification pending
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| three-phase | — | Frequency not stated · model ISO unspecified | Source · OEM_SOURCEMotor version: three-phaseRetrieved 2026-10-02 |
Operating Fluid · Needs review · 1 observations / 1 sources · classification pending
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| D2 | — | Frequency not stated · model ISO unspecified | Source · OEM_SOURCEOperating fluid: D2Retrieved 2026-10-02 |
Operating Fluid Filling · Needs review · 1 observations / 1 sources · classification pending
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 3.2 l l | 3.2 l | Frequency not stated · model ISO unspecified | Source · OEM_VERIFIEDOperating fluid filling: 3.2 lRetrieved 2026-10-02 |
Protection Degree · Needs review · 1 observations / 1 sources · classification pending
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| IP54; type 12 | — | Frequency not stated · model ISO unspecified | Source · OEM_SOURCEProtection degree: IP54; type 12Retrieved 2026-10-02 |
Recommended Mains Fuse Capacity · Needs review · 1 observations / 1 sources · classification pending
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 25 A A | 25 A | Frequency not stated · model ISO unspecified | Source · OEM_VERIFIEDRecommended mains fuse capacity: 25 ARetrieved 2026-10-02 |
Secondary Flange Size Type · Needs review · 1 observations / 1 sources · classification pending
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| DN 160 ISO-F | DN 150 PN 16 | — | Frequency not stated · model ISO unspecified | Source · OEM_SOURCESecondary Flange Size/Type: DN 160 ISO-F | DN 150 PN 16Retrieved 2026-10-02 |
Shipping Temperature · Needs review · 1 observations / 1 sources · classification pending
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| -10-40 °C °C | -10 °C | Frequency not stated · range ISO unspecified | Source · OEM_VERIFIED not a model rating Shipping temperature: -10-40 °CRetrieved 2026-10-02 |
Operating-performance coverage
Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.
No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.
Document coverage
Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.
| Category | Model links | Family links | Public sources |
|---|---|---|---|
| Specifications | 1 | 0 |
|
| Performance curves / test data | 0 | 0 | Not collected |
| Operation / service manuals | 1 | 0 |
|
| Parts documentation | 0 | 0 | Not collected |
| Drawings / dimensions | 0 | 0 | Not collected |
| Product / family literature | 0 | 0 | Not collected |
| Other / unclassified | 0 | 0 | Not collected |