Find equipmentComparePartsManufacturersTechnologiesIndustriesApplicationsAsset trackingMy equipmentTalk to a specialist

Data coverage & sources

The stored record for Pfeiffer Vacuum+Fab Solutions HiLobe 8104: specifications, configurations, documents, sources, and gaps.

One model, connected records

Pfeiffer Vacuum+Fab Solutions → HiLobe 8104-14004 → HiLobe 8104

Manufacturer model: HiLobe 8104 · OEM article / order number: Not collected · Equipment type: booster

Technology: Roots / Booster

Related applications: Leak Testing, Process Vacuum
Related industries: Automotive, Chemical, Metalworking, Oil + Gas, Power Generation, Semiconductor

These are technology associations. Check the operating point and process requirements to establish suitability for this model.

Compare coverage across this family

Specifications and evidence

23 stored observations · 6 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.

The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.

Pumping speed · Needs review · 1 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
2700-8120 m³/h m³/h2700 m3/hFrequency not stated · range
ISO
unspecified
Source · OEM_VERIFIED
not a model rating
Nominal pumping speed: 2700-8120 m³/h
Retrieved 2026-10-02
Ultimate pressure · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Motor power · Sourced · 1 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
9 kW kW9 kWFrequency not stated · model
ISO; at full rotational speed
unspecified
Source · OEM_VERIFIED
Rated power at full rotational speed: 9 kW
Retrieved 2026-10-02
Speed · Needs review · 1 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
1500-4500 rpm rpm1500 rpmFrequency not stated · range
ISO
unspecified
Source · OEM_VERIFIED
not a model rating
Rotational speed: 1500-4500 rpm
Retrieved 2026-10-02
Noise level · Sourced · 1 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
75 dB(A) dB(A)75 dB(A)Frequency not stated · model
ISO; (EN ISO 2151) at inlet pressure 1 hPa
unspecified
Source · OEM_SOURCE
Sound pressure level (EN ISO 2151) at inlet pressure 1 hPa: 75 dB(A)
Retrieved 2026-10-02
Weight · Sourced · 1 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
670 kg kg670 kgFrequency not stated · model
ISO; approx.
unspecified
Source · OEM_VERIFIED
Weight approx.: 670 kg
Retrieved 2026-10-02
Dimensions · Sourced · 1 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
1433 x 583 x 468 mm mm— Frequency not stated · model
ISO; (L x W x H)
unspecified
Source · OEM_SOURCE
Dimensions (L x W x H): 1433 x 583 x 468 mm
Retrieved 2026-10-02
Inlet connection · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Outlet connection · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Ambient temperature · Needs review · 1 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
5-40 °C °C5 °CFrequency not stated · range
ISO
unspecified
Source · OEM_VERIFIED
not a model rating
Ambient temperature: 5-40 °C
Retrieved 2026-10-02
Cooling Method · Needs review · 1 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
Active air cooling — Frequency not stated · model
ISO
unspecified
Source · OEM_SOURCE
Cooling method: Active air cooling
Retrieved 2026-10-02
Electronic Drive Unit · Needs review · 1 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
RC 15000 — Frequency not stated · model
ISO
unspecified
Source · OEM_SOURCE
Electronic drive unit: RC 15000
Retrieved 2026-10-02
Input Voltages · Needs review · 1 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
380-480 AC (±10), 50/60 Hz AC AC (±10), 50/60 Hz AC— Frequency not stated · range
ISO
unspecified
Source · OEM_SOURCE
not a model rating
Input Voltages: 380-480 AC (±10), 50/60 Hz AC
Retrieved 2026-10-02
Integral Leak Rate · Needs review · 1 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
1E-06 Pa m³/s Pa m³/s E-06 Pa m³/s Pa m³/s— Frequency not stated · model
ISO
unspecified
Source · OEM_SOURCE
Integral leak rate: 1E-06 Pa m³/s Pa m³/s
Retrieved 2026-10-02
I O Interfaces · Needs review · 1 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
PV.can; RS485 — Frequency not stated · model
ISO
unspecified
Source · OEM_SOURCE
I/O Interfaces: PV.can; RS485
Retrieved 2026-10-02
Main Flange Size Type · Needs review · 1 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
DN 250 ISO-F | DN 250 PN 16 — Frequency not stated · model
ISO
unspecified
Source · OEM_SOURCE
Main Flange Size/Type: DN 250 ISO-F | DN 250 PN 16
Retrieved 2026-10-02
Max. vacuum · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
25 hPa hPa25 mbarFrequency not stated · model
ISO; at max. rotational speed
unspecified
Source · OEM_SOURCE
Max. differential pressure at max. rotational speed: 25 hPa
Retrieved 2026-10-02
30 hPa hPa30 mbarFrequency not stated · model
ISO; max. at min. rotational speed
unspecified
Source · OEM_SOURCE
Max. differential pressure max. at min. rotational speed: 30 hPa
Retrieved 2026-10-02
Motor Protection · Needs review · 1 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
PTC — Frequency not stated · model
ISO
unspecified
Source · OEM_SOURCE
Motor protection: PTC
Retrieved 2026-10-02
Motor Version · Needs review · 1 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
three-phase — Frequency not stated · model
ISO
unspecified
Source · OEM_SOURCE
Motor version: three-phase
Retrieved 2026-10-02
Operating Fluid · Needs review · 1 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
D2 — Frequency not stated · model
ISO
unspecified
Source · OEM_SOURCE
Operating fluid: D2
Retrieved 2026-10-02
Operating Fluid Filling · Needs review · 1 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
5.2 l l5.2 lFrequency not stated · model
ISO
unspecified
Source · OEM_VERIFIED
Operating fluid filling: 5.2 l
Retrieved 2026-10-02
Protection Degree · Needs review · 1 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
IP54; type 12 — Frequency not stated · model
ISO
unspecified
Source · OEM_SOURCE
Protection degree: IP54; type 12
Retrieved 2026-10-02
Recommended Mains Fuse Capacity · Needs review · 1 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
50 A A50 AFrequency not stated · model
ISO
unspecified
Source · OEM_VERIFIED
Recommended mains fuse capacity: 50 A
Retrieved 2026-10-02
Secondary Flange Size Type · Needs review · 1 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
DN 250 ISO-F | DN 250 PN 16 — Frequency not stated · model
ISO
unspecified
Source · OEM_SOURCE
Secondary Flange Size/Type: DN 250 ISO-F | DN 250 PN 16
Retrieved 2026-10-02
Shipping Temperature · Needs review · 1 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
-10-40 °C °C-10 °CFrequency not stated · range
ISO
unspecified
Source · OEM_VERIFIED
not a model rating
Shipping temperature: -10-40 °C
Retrieved 2026-10-02

Operating-performance coverage

Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.

No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.

Document coverage

Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.

CategoryModel linksFamily linksPublic sources
Specifications10
Performance curves / test data00Not collected
Operation / service manuals10
Parts documentation00Not collected
Drawings / dimensions00Not collected
Product / family literature00Not collected
Other / unclassified00Not collected