Data coverage & sources
The stored record for Pneumatic Products 259NGPHS: specifications, configurations, documents, sources, and gaps.
One model, connected records
Pneumatic Products → NGPHS – Heavy Duty Nitrogen Generator → 259NGPHS
Manufacturer model: 259NGPHS · OEM article / order number: Not collected · Equipment type: gas generator
Technology: Nitrogen Generators / Air Treatment
Related applications: Plant Air
Related industries: Not mapped
These are technology associations. Check the operating point and process requirements to establish suitability for this model.
Compare coverage across this familySpecifications and evidence
24 stored observations · 24 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.
The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.
Gas output · Sourced · 22 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 223.1 scfm | 379.0491 m3/h | Frequency not stated · model at 95% purity, 70 °F ambient, 110 psig inlet standard | Source · OEM_SOURCEFlow: 223.1Retrieved 2026-10-05 |
| 202.9 scfm | 344.7291 m3/h | Frequency not stated · model at 96% purity, 70 °F ambient, 110 psig inlet standard | Source · OEM_SOURCEFlow: 202.9Retrieved 2026-10-05 |
| 187.1 scfm | 317.8848 m3/h | Frequency not stated · model at 97% purity, 70 °F ambient, 110 psig inlet standard | Source · OEM_SOURCEFlow: 187.1Retrieved 2026-10-05 |
| 157.4 scfm | 267.4242 m3/h | Frequency not stated · model at 98% purity, 70 °F ambient, 110 psig inlet standard | Source · OEM_SOURCEFlow: 157.4Retrieved 2026-10-05 |
| 126.8 scfm | 215.4345 m3/h | Frequency not stated · model at 99% purity, 70 °F ambient, 110 psig inlet standard | Source · OEM_SOURCEFlow: 126.8Retrieved 2026-10-05 |
| 112.0 scfm | 190.2891 m3/h | Frequency not stated · model at 99.5% purity, 70 °F ambient, 110 psig inlet standard | Source · OEM_SOURCEFlow: 112.0Retrieved 2026-10-05 |
| 84.3 scfm | 143.2265 m3/h | Frequency not stated · model at 99.9% purity, 70 °F ambient, 110 psig inlet standard | Source · OEM_SOURCEFlow: 84.3Retrieved 2026-10-05 |
| 74.6 scfm | 126.7461 m3/h | Frequency not stated · model at 99.95% purity, 70 °F ambient, 110 psig inlet standard | Source · OEM_SOURCEFlow: 74.6Retrieved 2026-10-05 |
| 56.1 scfm | 95.3145 m3/h | Frequency not stated · model at 99.99% purity, 70 °F ambient, 110 psig inlet standard | Source · OEM_SOURCEFlow: 56.1Retrieved 2026-10-05 |
| 48.7 scfm | 82.7418 m3/h | Frequency not stated · model at 99.995% purity, 70 °F ambient, 110 psig inlet standard | Source · OEM_SOURCEFlow: 48.7Retrieved 2026-10-05 |
| 36.6 scfm | 62.1838 m3/h | Frequency not stated · model at 99.999% purity, 70 °F ambient, 110 psig inlet standard | Source · OEM_SOURCEFlow: 36.6Retrieved 2026-10-05 |
| 210.0 scfm | 356.7921 m3/h | Frequency not stated · model at 95% purity, 95 °F ambient, 110 psig inlet standard | Source · OEM_SOURCEFlow: 210.0Retrieved 2026-10-05 |
| 194.2 scfm | 329.9477 m3/h | Frequency not stated · model at 96% purity, 95 °F ambient, 110 psig inlet standard | Source · OEM_SOURCEFlow: 194.2Retrieved 2026-10-05 |
| 173.6 scfm | 294.9481 m3/h | Frequency not stated · model at 97% purity, 95 °F ambient, 110 psig inlet standard | Source · OEM_SOURCEFlow: 173.6Retrieved 2026-10-05 |
| 148.9 scfm | 252.9826 m3/h | Frequency not stated · model at 98% purity, 95 °F ambient, 110 psig inlet standard | Source · OEM_SOURCEFlow: 148.9Retrieved 2026-10-05 |
| 119.8 scfm | 203.5414 m3/h | Frequency not stated · model at 99% purity, 95 °F ambient, 110 psig inlet standard | Source · OEM_SOURCEFlow: 119.8Retrieved 2026-10-05 |
| 103.9 scfm | 176.5271 m3/h | Frequency not stated · model at 99.5% purity, 95 °F ambient, 110 psig inlet standard | Source · OEM_SOURCEFlow: 103.9Retrieved 2026-10-05 |
| 76.9 scfm | 130.6539 m3/h | Frequency not stated · model at 99.9% purity, 95 °F ambient, 110 psig inlet standard | Source · OEM_SOURCEFlow: 76.9Retrieved 2026-10-05 |
| 67.6 scfm | 114.8531 m3/h | Frequency not stated · model at 99.95% purity, 95 °F ambient, 110 psig inlet standard | Source · OEM_SOURCEFlow: 67.6Retrieved 2026-10-05 |
| 50.0 scfm | 84.9505 m3/h | Frequency not stated · model at 99.99% purity, 95 °F ambient, 110 psig inlet standard | Source · OEM_SOURCEFlow: 50.0Retrieved 2026-10-05 |
| 44.0 scfm | 74.7564 m3/h | Frequency not stated · model at 99.995% purity, 95 °F ambient, 110 psig inlet standard | Source · OEM_SOURCEFlow: 44.0Retrieved 2026-10-05 |
| 32.6 scfm | 55.3877 m3/h | Frequency not stated · model at 99.999% purity, 95 °F ambient, 110 psig inlet standard | Source · OEM_SOURCEFlow: 32.6Retrieved 2026-10-05 |
Max. pressure · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Power consumption · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Dimensions · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Reference working pressure · Sourced · 1 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 110 psig | 110 psig | Frequency not stated · model the pressure "Flow" is stated at (at 95% purity, 70 °F ambient, 110 psig inlet) unspecified | Source · OEM_SOURCEFlow: 223.1Retrieved 2026-10-20 |
Weight · Sourced · 1 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 5,930 lb. | 2689.801 kg | Frequency not stated · model Conditions not stated unspecified | Source · OEM_SOURCEWeight: 5,930Retrieved 2026-10-05 |
Operating-performance coverage
Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.
No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.
Document coverage
Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.
| Category | Model links | Family links | Public sources |
|---|---|---|---|
| Specifications | 0 | 0 | Not collected |
| Performance curves / test data | 0 | 0 | Not collected |
| Operation / service manuals | 0 | 0 | Not collected |
| Parts documentation | 0 | 0 | Not collected |
| Drawings / dimensions | 0 | 0 | Not collected |
| Product / family literature | 1 | 0 |
|
| Other / unclassified | 0 | 0 | Not collected |