Data coverage & sources
The stored record for Pneumatic Products 285NGPHS: specifications, configurations, documents, sources, and gaps.
One model, connected records
Pneumatic Products → NGPHS – Heavy Duty Nitrogen Generator → 285NGPHS
Manufacturer model: 285NGPHS · OEM article / order number: Not collected · Equipment type: gas generator
Technology: Nitrogen Generators / Air Treatment
Related applications: Plant Air
Related industries: Not mapped
These are technology associations. Check the operating point and process requirements to establish suitability for this model.
Compare coverage across this familySpecifications and evidence
24 stored observations · 24 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.
The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.
Gas output · Sourced · 22 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 245.0 scfm | 416.2575 m3/h | Frequency not stated · model at 95% purity, 70 °F ambient, 110 psig inlet standard | Source · OEM_SOURCEFlow: 245.0Retrieved 2026-10-05 |
| 222.8 scfm | 378.5394 m3/h | Frequency not stated · model at 96% purity, 70 °F ambient, 110 psig inlet standard | Source · OEM_SOURCEFlow: 222.8Retrieved 2026-10-05 |
| 205.5 scfm | 349.1466 m3/h | Frequency not stated · model at 97% purity, 70 °F ambient, 110 psig inlet standard | Source · OEM_SOURCEFlow: 205.5Retrieved 2026-10-05 |
| 172.9 scfm | 293.7588 m3/h | Frequency not stated · model at 98% purity, 70 °F ambient, 110 psig inlet standard | Source · OEM_SOURCEFlow: 172.9Retrieved 2026-10-05 |
| 139.3 scfm | 236.6721 m3/h | Frequency not stated · model at 99% purity, 70 °F ambient, 110 psig inlet standard | Source · OEM_SOURCEFlow: 139.3Retrieved 2026-10-05 |
| 123.0 scfm | 208.9782 m3/h | Frequency not stated · model at 99.5% purity, 70 °F ambient, 110 psig inlet standard | Source · OEM_SOURCEFlow: 123.0Retrieved 2026-10-05 |
| 92.6 scfm | 157.3283 m3/h | Frequency not stated · model at 99.9% purity, 70 °F ambient, 110 psig inlet standard | Source · OEM_SOURCEFlow: 92.6Retrieved 2026-10-05 |
| 81.9 scfm | 139.1489 m3/h | Frequency not stated · model at 99.95% purity, 70 °F ambient, 110 psig inlet standard | Source · OEM_SOURCEFlow: 81.9Retrieved 2026-10-05 |
| 61.6 scfm | 104.659 m3/h | Frequency not stated · model at 99.99% purity, 70 °F ambient, 110 psig inlet standard | Source · OEM_SOURCEFlow: 61.6Retrieved 2026-10-05 |
| 53.5 scfm | 90.897 m3/h | Frequency not stated · model at 99.995% purity, 70 °F ambient, 110 psig inlet standard | Source · OEM_SOURCEFlow: 53.5Retrieved 2026-10-05 |
| 40.2 scfm | 68.3002 m3/h | Frequency not stated · model at 99.999% purity, 70 °F ambient, 110 psig inlet standard | Source · OEM_SOURCEFlow: 40.2Retrieved 2026-10-05 |
| 230.6 scfm | 391.7917 m3/h | Frequency not stated · model at 95% purity, 95 °F ambient, 110 psig inlet standard | Source · OEM_SOURCEFlow: 230.6Retrieved 2026-10-05 |
| 213.2 scfm | 362.2289 m3/h | Frequency not stated · model at 96% purity, 95 °F ambient, 110 psig inlet standard | Source · OEM_SOURCEFlow: 213.2Retrieved 2026-10-05 |
| 190.6 scfm | 323.8313 m3/h | Frequency not stated · model at 97% purity, 95 °F ambient, 110 psig inlet standard | Source · OEM_SOURCEFlow: 190.6Retrieved 2026-10-05 |
| 163.6 scfm | 277.958 m3/h | Frequency not stated · model at 98% purity, 95 °F ambient, 110 psig inlet standard | Source · OEM_SOURCEFlow: 163.6Retrieved 2026-10-05 |
| 131.5 scfm | 223.4198 m3/h | Frequency not stated · model at 99% purity, 95 °F ambient, 110 psig inlet standard | Source · OEM_SOURCEFlow: 131.5Retrieved 2026-10-05 |
| 114.1 scfm | 193.857 m3/h | Frequency not stated · model at 99.5% purity, 95 °F ambient, 110 psig inlet standard | Source · OEM_SOURCEFlow: 114.1Retrieved 2026-10-05 |
| 84.5 scfm | 143.5663 m3/h | Frequency not stated · model at 99.9% purity, 95 °F ambient, 110 psig inlet standard | Source · OEM_SOURCEFlow: 84.5Retrieved 2026-10-05 |
| 74.2 scfm | 126.0665 m3/h | Frequency not stated · model at 99.95% purity, 95 °F ambient, 110 psig inlet standard | Source · OEM_SOURCEFlow: 74.2Retrieved 2026-10-05 |
| 55.0 scfm | 93.4456 m3/h | Frequency not stated · model at 99.99% purity, 95 °F ambient, 110 psig inlet standard | Source · OEM_SOURCEFlow: 55.0Retrieved 2026-10-05 |
| 48.3 scfm | 82.0622 m3/h | Frequency not stated · model at 99.995% purity, 95 °F ambient, 110 psig inlet standard | Source · OEM_SOURCEFlow: 48.3Retrieved 2026-10-05 |
| 35.7 scfm | 60.6547 m3/h | Frequency not stated · model at 99.999% purity, 95 °F ambient, 110 psig inlet standard | Source · OEM_SOURCEFlow: 35.7Retrieved 2026-10-05 |
Max. pressure · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Power consumption · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Dimensions · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Reference working pressure · Sourced · 1 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 110 psig | 110 psig | Frequency not stated · model the pressure "Flow" is stated at (at 95% purity, 70 °F ambient, 110 psig inlet) unspecified | Source · OEM_SOURCEFlow: 245.0Retrieved 2026-10-20 |
Weight · Sourced · 1 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 6,120 lb. | 2775.983 kg | Frequency not stated · model Conditions not stated unspecified | Source · OEM_SOURCEWeight: 6,120Retrieved 2026-10-05 |
Operating-performance coverage
Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.
No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.
Document coverage
Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.
| Category | Model links | Family links | Public sources |
|---|---|---|---|
| Specifications | 0 | 0 | Not collected |
| Performance curves / test data | 0 | 0 | Not collected |
| Operation / service manuals | 0 | 0 | Not collected |
| Parts documentation | 0 | 0 | Not collected |
| Drawings / dimensions | 0 | 0 | Not collected |
| Product / family literature | 1 | 0 |
|