Find equipmentComparePartsManufacturersTechnologiesIndustriesApplicationsAsset trackingMy equipmentTalk to a specialist

Data coverage & sources

The stored record for Pneumatic Products 68NGPLS: specifications, configurations, documents, sources, and gaps.

One model, connected records

Pneumatic Products → NGPLS – Light Duty Nitrogen Generator → 68NGPLS

Manufacturer model: 68NGPLS · OEM article / order number: Not collected · Equipment type: gas generator

Technology: Nitrogen Generators / Air Treatment

Related applications: Plant Air
Related industries: Not mapped

These are technology associations. Check the operating point and process requirements to establish suitability for this model.

Compare coverage across this family

Specifications and evidence

24 stored observations · 24 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.

The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.

Gas output · Sourced · 22 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
58.4 scfm99.2222 m3/hFrequency not stated · model
at 95% purity, 70 °F ambient, 110 psig inlet
standard
Source · OEM_SOURCE
Flow: 58.4
Retrieved 2026-10-05
53.1 scfm90.2174 m3/hFrequency not stated · model
at 96% purity, 70 °F ambient, 110 psig inlet
standard
Source · OEM_SOURCE
Flow: 53.1
Retrieved 2026-10-05
49.0 scfm83.2515 m3/hFrequency not stated · model
at 97% purity, 70 °F ambient, 110 psig inlet
standard
Source · OEM_SOURCE
Flow: 49.0
Retrieved 2026-10-05
41.2 scfm69.9992 m3/hFrequency not stated · model
at 98% purity, 70 °F ambient, 110 psig inlet
standard
Source · OEM_SOURCE
Flow: 41.2
Retrieved 2026-10-05
33.2 scfm56.4071 m3/hFrequency not stated · model
at 99% purity, 70 °F ambient, 110 psig inlet
standard
Source · OEM_SOURCE
Flow: 33.2
Retrieved 2026-10-05
29.3 scfm49.781 m3/hFrequency not stated · model
at 99.5% purity, 70 °F ambient, 110 psig inlet
standard
Source · OEM_SOURCE
Flow: 29.3
Retrieved 2026-10-05
22.1 scfm37.5481 m3/hFrequency not stated · model
at 99.9% purity, 70 °F ambient, 110 psig inlet
standard
Source · OEM_SOURCE
Flow: 22.1
Retrieved 2026-10-05
19.5 scfm33.1307 m3/hFrequency not stated · model
at 99.95% purity, 70 °F ambient, 110 psig inlet
standard
Source · OEM_SOURCE
Flow: 19.5
Retrieved 2026-10-05
14.7 scfm24.9754 m3/hFrequency not stated · model
at 99.99% purity, 70 °F ambient, 110 psig inlet
standard
Source · OEM_SOURCE
Flow: 14.7
Retrieved 2026-10-05
12.8 scfm21.7473 m3/hFrequency not stated · model
at 99.995% purity, 70 °F ambient, 110 psig inlet
standard
Source · OEM_SOURCE
Flow: 12.8
Retrieved 2026-10-05
9.6 scfm16.3105 m3/hFrequency not stated · model
at 99.999% purity, 70 °F ambient, 110 psig inlet
standard
Source · OEM_SOURCE
Flow: 9.6
Retrieved 2026-10-05
54.9 scfm93.2756 m3/hFrequency not stated · model
at 95% purity, 95 °F ambient, 110 psig inlet
standard
Source · OEM_SOURCE
Flow: 54.9
Retrieved 2026-10-05
50.8 scfm86.3097 m3/hFrequency not stated · model
at 96% purity, 95 °F ambient, 110 psig inlet
standard
Source · OEM_SOURCE
Flow: 50.8
Retrieved 2026-10-05
45.4 scfm77.1351 m3/hFrequency not stated · model
at 97% purity, 95 °F ambient, 110 psig inlet
standard
Source · OEM_SOURCE
Flow: 45.4
Retrieved 2026-10-05
39.0 scfm66.2614 m3/hFrequency not stated · model
at 98% purity, 95 °F ambient, 110 psig inlet
standard
Source · OEM_SOURCE
Flow: 39.0
Retrieved 2026-10-05
31.3 scfm53.179 m3/hFrequency not stated · model
at 99% purity, 95 °F ambient, 110 psig inlet
standard
Source · OEM_SOURCE
Flow: 31.3
Retrieved 2026-10-05
27.2 scfm46.2131 m3/hFrequency not stated · model
at 99.5% purity, 95 °F ambient, 110 psig inlet
standard
Source · OEM_SOURCE
Flow: 27.2
Retrieved 2026-10-05
20.1 scfm34.1501 m3/hFrequency not stated · model
at 99.9% purity, 95 °F ambient, 110 psig inlet
standard
Source · OEM_SOURCE
Flow: 20.1
Retrieved 2026-10-05
17.7 scfm30.0725 m3/hFrequency not stated · model
at 99.95% purity, 95 °F ambient, 110 psig inlet
standard
Source · OEM_SOURCE
Flow: 17.7
Retrieved 2026-10-05
13.1 scfm22.257 m3/hFrequency not stated · model
at 99.99% purity, 95 °F ambient, 110 psig inlet
standard
Source · OEM_SOURCE
Flow: 13.1
Retrieved 2026-10-05
11.5 scfm19.5386 m3/hFrequency not stated · model
at 99.995% purity, 95 °F ambient, 110 psig inlet
standard
Source · OEM_SOURCE
Flow: 11.5
Retrieved 2026-10-05
8.5 scfm14.4416 m3/hFrequency not stated · model
at 99.999% purity, 95 °F ambient, 110 psig inlet
standard
Source · OEM_SOURCE
Flow: 8.5
Retrieved 2026-10-05
Max. pressure · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Power consumption · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Dimensions · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Reference working pressure · Sourced · 1 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
110 psig110 psigFrequency not stated · model
the pressure "Flow" is stated at (at 95% purity, 70 °F ambient, 110 psig inlet)
unspecified
Source · OEM_SOURCE
Flow: 58.4
Retrieved 2026-10-20
Weight · Sourced · 1 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
1443 lb.654.5333 kgFrequency not stated · model
Conditions not stated
unspecified
Source · OEM_SOURCE
Weight: 1443
Retrieved 2026-10-05

Operating-performance coverage

Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.

No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.

Document coverage

Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.

CategoryModel linksFamily linksPublic sources
Specifications00Not collected
Performance curves / test data00Not collected
Operation / service manuals00Not collected
Parts documentation00Not collected
Drawings / dimensions00Not collected
Product / family literature10