Data coverage & sources
The stored record for Pneumofore UV16: specifications, configurations, documents, sources, and gaps.
One model, connected records
Pneumofore → Pneumofore UV Series → UV16
Manufacturer model: UV16 · OEM article / order number: Not collected · Equipment type: vacuum pump
Technology: Oil-Lubricated Rotary Vane
Related applications: Central Vacuum, Degassing, Drying, Leak Testing, Medical Suction, Packaging, Vacuum Forming
Related industries: Automotive, Food + Beverage, Medical, Metalworking, Packaging, Plastics
These are technology associations. Check the operating point and process requirements to establish suitability for this model.
Compare coverage across this familySpecifications and evidence
18 stored observations · 10 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.
The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.
Pumping speed · Sourced · 6 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 969 m³/h | 969 m3/h | 50 Hz · model 100 mbar(a), 50 Hz unspecified | Source · OEM_SOURCE different frequency Capacity: 969Retrieved 2026-10-03 |
| 1.143 m³/h | 1143 m3/h | 60 Hz · model 100 mbar(a), 60 Hz unspecified | Source · OEM_SOURCECapacity: 1.143Retrieved 2026-10-03 |
| 998 m³/h | 998 m3/h | 50 Hz · model 200 mbar(a), 50 Hz unspecified | Source · OEM_SOURCE different frequency Capacity: 998Retrieved 2026-10-03 |
| 1.177 m³/h | 1177 m3/h | 60 Hz · model 200 mbar(a), 60 Hz unspecified | Source · OEM_SOURCECapacity: 1.177Retrieved 2026-10-03 |
| 1.000 m³/h | 1000 m3/h | 50 Hz · model 300 mbar(a), 50 Hz unspecified | Source · OEM_SOURCE different frequency Capacity: 1.000Retrieved 2026-10-03 |
| 1.179 m³/h | 1179 m3/h | 60 Hz · model 300 mbar(a), 60 Hz unspecified | Source · OEM_SOURCECapacity: 1.179Retrieved 2026-10-03 |
Ultimate pressure · Sourced · 1 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 0,5 mbar(a) | 0.5 mbar | Frequency not stated · series as printed: "residual pressure"; stated for the whole series unspecified | Source · OEM_SOURCEModels from UV4 to UV100 with a capacity range of 250 to 7.160 m 3/h and up to 0,5 mbar(a) residual pressure.Retrieved 2026-10-20 |
Motor power · Other conditions · 1 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 22 kW | 22 kW | 50 Hz · model 50 Hz unspecified | Source · OEM_SOURCE different frequency Nominal power: 22Retrieved 2026-10-03 |
Speed · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Noise level · Sourced · 2 observations / 1 sources
Weight · Sourced · 1 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 1.250 kg | 1250 kg | Frequency not stated · model Conditions not stated unspecified | Source · OEM_SOURCEWeight: 1.250Retrieved 2026-10-03 |
Dimensions · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Inlet connection · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Outlet connection · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Max. vacuum · Sourced · 1 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 99,95 % | 99.95 % | Frequency not stated · series as printed: "maximum vacuum degree"; stated for the whole series; 0,5 mbar(a) unspecified | Source · OEM_SOURCE99,95% maximum vacuum degree [0,5 mbar(a) residual absolute pressure]Retrieved 2026-10-20 |
Power consumption · Sourced · 6 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 16 kW | 16 kW | 50 Hz · model 100 mbar(a), 50 Hz unspecified | Source · OEM_SOURCE different frequency Absorbed power: 16Retrieved 2026-10-03 |
| 21 kW | 21 kW | 60 Hz · model 100 mbar(a), 60 Hz unspecified | Source · OEM_SOURCEAbsorbed power: 21Retrieved 2026-10-03 |
| 19 kW | 19 kW | 50 Hz · model 200 mbar(a), 50 Hz unspecified | Source · OEM_SOURCE different frequency Absorbed power: 19Retrieved 2026-10-03 |
| 24 kW | 24 kW | 60 Hz · model 200 mbar(a), 60 Hz unspecified | Source · OEM_SOURCEAbsorbed power: 24Retrieved 2026-10-03 |
| 20 kW | 20 kW | 50 Hz · model 300 mbar(a), 50 Hz unspecified | Source · OEM_SOURCE different frequency Absorbed power: 20Retrieved 2026-10-03 |
| 26 kW | 26 kW | 60 Hz · model 300 mbar(a), 60 Hz unspecified | Source · OEM_SOURCEAbsorbed power: 26Retrieved 2026-10-03 |
Operating-performance coverage
Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.
No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.
Document coverage
Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.
| Category | Model links | Family links | Public sources |
|---|---|---|---|
| Specifications | 1 | 0 |
|
| Performance curves / test data | 0 | 0 | Not collected |
| Operation / service manuals | 0 | 0 | Not collected |
| Parts documentation | 0 | 0 | Not collected |
| Drawings / dimensions | 0 | 0 | Not collected |
| Product / family literature | 2 | 0 |
|
| Other / unclassified | 0 | 0 | Not collected |