Data coverage & sources
The stored record for Pneumofore UV24: specifications, configurations, documents, sources, and gaps.
One model, connected records
Pneumofore → Pneumofore UV Series → UV24
Manufacturer model: UV24 · OEM article / order number: Not collected · Equipment type: vacuum pump
Technology: Oil-Lubricated Rotary Vane
Related applications: Central Vacuum, Degassing, Drying, Leak Testing, Medical Suction, Packaging, Vacuum Forming
Related industries: Automotive, Food + Beverage, Medical, Metalworking, Packaging, Plastics
These are technology associations. Check the operating point and process requirements to establish suitability for this model.
Compare coverage across this familySpecifications and evidence
18 stored observations · 10 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.
The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.
Pumping speed · Sourced · 6 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 1.301 m³/h | 1301 m3/h | 50 Hz · model 100 mbar(a), 50 Hz unspecified | Source · OEM_SOURCE different frequency Capacity: 1.301Retrieved 2026-10-03 |
| 1.534 m³/h | 1534 m3/h | 60 Hz · model 100 mbar(a), 60 Hz unspecified | Source · OEM_SOURCECapacity: 1.534Retrieved 2026-10-03 |
| 1.323 m³/h | 1323 m3/h | 50 Hz · model 200 mbar(a), 50 Hz unspecified | Source · OEM_SOURCE different frequency Capacity: 1.323Retrieved 2026-10-03 |
| 1.569 m³/h | 1569 m3/h | 60 Hz · model 200 mbar(a), 60 Hz unspecified | Source · OEM_SOURCECapacity: 1.569Retrieved 2026-10-03 |
| 1.325 m³/h | 1325 m3/h | 50 Hz · model 300 mbar(a), 50 Hz unspecified | Source · OEM_SOURCE different frequency Capacity: 1.325Retrieved 2026-10-03 |
| 1.571 m³/h | 1571 m3/h | 60 Hz · model 300 mbar(a), 60 Hz unspecified | Source · OEM_SOURCECapacity: 1.571Retrieved 2026-10-03 |
Ultimate pressure · Sourced · 1 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 0,5 mbar(a) | 0.5 mbar | Frequency not stated · series as printed: "residual pressure"; stated for the whole series unspecified | Source · OEM_SOURCEModels from UV4 to UV100 with a capacity range of 250 to 7.160 m 3/h and up to 0,5 mbar(a) residual pressure.Retrieved 2026-10-20 |
Motor power · Other conditions · 1 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 30 kW | 30 kW | 50 Hz · model 50 Hz unspecified | Source · OEM_SOURCE different frequency Nominal power: 30Retrieved 2026-10-03 |
Speed · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Noise level · Sourced · 2 observations / 1 sources
Weight · Sourced · 1 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 1.700 kg | 1700 kg | Frequency not stated · model Conditions not stated unspecified | Source · OEM_SOURCEWeight: 1.700Retrieved 2026-10-03 |
Dimensions · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Inlet connection · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Outlet connection · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Max. vacuum · Sourced · 1 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 99,95 % | 99.95 % | Frequency not stated · series as printed: "maximum vacuum degree"; stated for the whole series; 0,5 mbar(a) unspecified | Source · OEM_SOURCE99,95% maximum vacuum degree [0,5 mbar(a) residual absolute pressure]Retrieved 2026-10-20 |
Power consumption · Sourced · 6 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 24 kW | 24 kW | 50 Hz · model 100 mbar(a), 50 Hz unspecified | Source · OEM_SOURCE different frequency Absorbed power: 24Retrieved 2026-10-03 |
| 31 kW | 31 kW | 60 Hz · model 100 mbar(a), 60 Hz unspecified | Source · OEM_SOURCEAbsorbed power: 31Retrieved 2026-10-03 |
| 26 kW | 26 kW | 50 Hz · model 200 mbar(a), 50 Hz unspecified | Source · OEM_SOURCE different frequency Absorbed power: 26Retrieved 2026-10-03 |
| 35 kW | 35 kW | 60 Hz · model 200 mbar(a), 60 Hz unspecified | Source · OEM_SOURCEAbsorbed power: 35Retrieved 2026-10-03 |
| 28 kW | 28 kW | 50 Hz · model 300 mbar(a), 50 Hz unspecified | Source · OEM_SOURCE different frequency Absorbed power: 28Retrieved 2026-10-03 |
| 38 kW | 38 kW | 60 Hz · model 300 mbar(a), 60 Hz unspecified | Source · OEM_SOURCEAbsorbed power: 38Retrieved 2026-10-03 |
Operating-performance coverage
Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.
No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.
Document coverage
Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.
| Category | Model links | Family links | Public sources |
|---|---|---|---|
| Specifications | 1 | 0 |
|
| Performance curves / test data | 0 | 0 | Not collected |
| Operation / service manuals | 0 | 0 | Not collected |
| Parts documentation | 0 | 0 | Not collected |
| Drawings / dimensions | 0 | 0 | Not collected |
| Product / family literature | 2 | 0 |
|
| Other / unclassified | 0 | 0 | Not collected |