Find equipmentComparePartsManufacturersTechnologiesIndustriesApplicationsAsset trackingMy equipmentTalk to a specialist

Data coverage & sources

The stored record for Pneumofore UV8: specifications, configurations, documents, sources, and gaps.

One model, connected records

Pneumofore → Pneumofore UV Series → UV8

Manufacturer model: UV8 · OEM article / order number: Not collected · Equipment type: vacuum pump

Technology: Oil-Lubricated Rotary Vane

Related applications: Central Vacuum, Degassing, Drying, Leak Testing, Medical Suction, Packaging, Vacuum Forming
Related industries: Automotive, Food + Beverage, Medical, Metalworking, Packaging, Plastics

These are technology associations. Check the operating point and process requirements to establish suitability for this model.

Compare coverage across this family

Specifications and evidence

18 stored observations · 10 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.

The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.

Pumping speed · Sourced · 6 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
409 m³/h409 m3/h50 Hz · model
100 mbar(a), 50 Hz
unspecified
Source · OEM_SOURCE
different frequency
Capacity: 409
Retrieved 2026-10-03
488 m³/h488 m3/h60 Hz · model
100 mbar(a), 60 Hz
unspecified
Source · OEM_SOURCE
Capacity: 488
Retrieved 2026-10-03
427 m³/h427 m3/h50 Hz · model
200 mbar(a), 50 Hz
unspecified
Source · OEM_SOURCE
different frequency
Capacity: 427
Retrieved 2026-10-03
507 m³/h507 m3/h60 Hz · model
200 mbar(a), 60 Hz
unspecified
Source · OEM_SOURCE
Capacity: 507
Retrieved 2026-10-03
443 m³/h443 m3/h50 Hz · model
300 mbar(a), 50 Hz
unspecified
Source · OEM_SOURCE
different frequency
Capacity: 443
Retrieved 2026-10-03
527 m³/h527 m3/h60 Hz · model
300 mbar(a), 60 Hz
unspecified
Source · OEM_SOURCE
Capacity: 527
Retrieved 2026-10-03
Ultimate pressure · Sourced · 1 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
0,5 mbar(a)0.5 mbarFrequency not stated · series
as printed: "residual pressure"; stated for the whole series
unspecified
Source · OEM_SOURCE
Models from UV4 to UV100 with a capacity range of 250 to 7.160 m 3/h and up to 0,5 mbar(a) residual pressure.
Retrieved 2026-10-20
Motor power · Other conditions · 1 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
11 kW11 kW50 Hz · model
50 Hz
unspecified
Source · OEM_SOURCE
different frequency
Nominal power: 11
Retrieved 2026-10-03
Speed · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Noise level · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
68 dB(A)68 dB(A)50 Hz · model
50 Hz
unspecified
Source · OEM_SOURCE
different frequency
Noise: 68
Retrieved 2026-10-03
69 dB(A)69 dB(A)60 Hz · model
60 Hz
unspecified
Source · OEM_SOURCE
Noise: 69
Retrieved 2026-10-03
Weight · Sourced · 1 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
730 kg730 kgFrequency not stated · model
Conditions not stated
unspecified
Source · OEM_SOURCE
Weight: 730
Retrieved 2026-10-03
Dimensions · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Inlet connection · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Outlet connection · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Max. vacuum · Sourced · 1 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
99,95 %99.95 %Frequency not stated · series
as printed: "maximum vacuum degree"; stated for the whole series; 0,5 mbar(a)
unspecified
Source · OEM_SOURCE
99,95% maximum vacuum degree [0,5 mbar(a) residual absolute pressure]
Retrieved 2026-10-20
Power consumption · Sourced · 6 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
9 kW9 kW50 Hz · model
100 mbar(a), 50 Hz
unspecified
Source · OEM_SOURCE
different frequency
Absorbed power: 9
Retrieved 2026-10-03
11 kW11 kW60 Hz · model
100 mbar(a), 60 Hz
unspecified
Source · OEM_SOURCE
Absorbed power: 11
Retrieved 2026-10-03
9 kW9 kW50 Hz · model
200 mbar(a), 50 Hz
unspecified
Source · OEM_SOURCE
different frequency
Absorbed power: 9
Retrieved 2026-10-03
11 kW11 kW60 Hz · model
200 mbar(a), 60 Hz
unspecified
Source · OEM_SOURCE
Absorbed power: 11
Retrieved 2026-10-03
10 kW10 kW50 Hz · model
300 mbar(a), 50 Hz
unspecified
Source · OEM_SOURCE
different frequency
Absorbed power: 10
Retrieved 2026-10-03
12 kW12 kW60 Hz · model
300 mbar(a), 60 Hz
unspecified
Source · OEM_SOURCE
Absorbed power: 12
Retrieved 2026-10-03

Operating-performance coverage

Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.

No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.

Document coverage

Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.

CategoryModel linksFamily linksPublic sources
Specifications10
Performance curves / test data00Not collected
Operation / service manuals00Not collected
Parts documentation00Not collected
Drawings / dimensions00Not collected
Product / family literature20