Data coverage & sources
The stored record for Quincy Compressor QSI-60: specifications, configurations, documents, sources, and gaps.
One model, connected records
Quincy Compressor → QSI → QSI-60
Manufacturer model: QSI-60 · OEM article / order number: Not collected · Equipment type: compressor
Technology: Rotary Screw
Related applications: Plant Air, Pressure Conveying, Spray + Finishing
Related industries: Automotive, Chemical, General Manufacturing, Metalworking, Mining, Oil + Gas, Packaging, Plastics, Power Generation, Printing, Pulp + Paper, Water + Wastewater, Woodworking + CNC
These are technology associations. Check the operating point and process requirements to establish suitability for this model.
Compare coverage across this familySpecifications and evidence
10 stored observations · 10 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.
The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.
Free air delivery · Sourced · 2 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 338.6 ACFM | 575.2848 m3/h | Frequency not stated · model 100/110 PSI version unspecified | Source · OEM_SOURCECapacity: 338.6Retrieved 2026-10-03 |
| 293.4 ACFM | 498.4895 m3/h | Frequency not stated · model 125/128 PSI version unspecified | Source · OEM_SOURCECapacity: 293.4Retrieved 2026-10-03 |
Max. pressure · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Motor power · Sourced · 2 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 45 KW | 45 kW | Frequency not stated · model 100/110 PSI version unspecified | Source · OEM_SOURCEMotor power: 45Retrieved 2026-10-03 |
| 45 KW | 45 kW | Frequency not stated · model 125/128 PSI version unspecified | Source · OEM_SOURCEMotor power: 45Retrieved 2026-10-03 |
Speed · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Noise level · Sourced · 2 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 81 DBA | 81 dB(A) | Frequency not stated · model 100/110 PSI version unspecified | Source · OEM_SOURCENoise level: 81Retrieved 2026-10-03 |
| 81 DBA | 81 dB(A) | Frequency not stated · model 125/128 PSI version unspecified | Source · OEM_SOURCENoise level: 81Retrieved 2026-10-03 |
Weight · Sourced · 2 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 2236 lbs. | 1014.232 kg | Frequency not stated · model 100/110 PSI version unspecified | Source · OEM_SOURCEWeight: 2236Retrieved 2026-10-03 |
| 2236 lbs. | 1014.232 kg | Frequency not stated · model 125/128 PSI version unspecified | Source · OEM_SOURCEWeight: 2236Retrieved 2026-10-03 |
Dimensions · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Inlet connection · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Outlet connection · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Reference working pressure · Sourced · 2 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 110 psi | 7584.236 mbar | Frequency not stated · model the pressure "Capacity" is stated at (100/110 PSI version) unspecified | Source · OEM_SOURCECapacity: 338.6Retrieved 2026-10-20 |
| 128 psi | 8825.293 mbar | Frequency not stated · model the pressure "Capacity" is stated at (125/128 PSI version) unspecified | Source · OEM_SOURCECapacity: 293.4Retrieved 2026-10-20 |
Operating-performance coverage
Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.
No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.
Document coverage
Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.
| Category | Model links | Family links | Public sources |
|---|---|---|---|
| Specifications | 0 | 0 | Not collected |
| Performance curves / test data | 0 | 0 | Not collected |
| Operation / service manuals | 0 | 0 | Not collected |
| Parts documentation | 0 | 0 | Not collected |
| Drawings / dimensions | 0 | 0 | Not collected |
| Product / family literature | 0 | 0 | Not collected |
| Other / unclassified | 0 | 0 | Not collected |