Find equipmentComparePartsManufacturersTechnologiesIndustriesApplicationsAsset trackingMy equipmentTalk to a specialist

Data coverage & sources

The stored record for Van Air Systems D12: specifications, configurations, documents, sources, and gaps.

One model, connected records

Van Air Systems → Van Air D Series → D12

Manufacturer model: D12 · OEM article / order number: Not collected · Equipment type: dryer

Technology: Dryers / Air Treatment

Related applications: Food-Contact Air, Instrument Air, Medical Air, Plant Air, Spray + Finishing
Related industries: Food + Beverage, General Manufacturing, Pharmaceutical, Power Generation, Semiconductor

These are technology associations. Check the operating point and process requirements to establish suitability for this model.

Compare coverage across this family

Specifications and evidence

17 stored observations · 17 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.

The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.

Rated capacity · Sourced · 8 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
22 scfm37.3782 m3/hFrequency not stated · model
at 10 PSIG
standard
Source · OEM_SOURCE
Maximum capacity: 22
Retrieved 2026-10-05
30 scfm50.9703 m3/hFrequency not stated · model
at 20 PSIG
standard
Source · OEM_SOURCE
Maximum capacity: 30
Retrieved 2026-10-05
65 scfm110.4357 m3/hFrequency not stated · model
at 60 PSIG
standard
Source · OEM_SOURCE
Maximum capacity: 65
Retrieved 2026-10-05
100 scfm169.901 m3/hFrequency not stated · model
at 100 PSIG
standard
Source · OEM_SOURCE
Maximum capacity: 100
Retrieved 2026-10-05
122 scfm207.2792 m3/hFrequency not stated · model
at 125 PSIG
standard
Source · OEM_SOURCE
Maximum capacity: 122
Retrieved 2026-10-05
144 scfm244.6574 m3/hFrequency not stated · model
at 150 PSIG
standard
Source · OEM_SOURCE
Maximum capacity: 144
Retrieved 2026-10-05
187 scfm317.7149 m3/hFrequency not stated · model
at 200 PSIG
standard
Source · OEM_SOURCE
Maximum capacity: 187
Retrieved 2026-10-05
231 scfm392.4713 m3/hFrequency not stated · model
at 250 PSIG
standard
Source · OEM_SOURCE
Maximum capacity: 231
Retrieved 2026-10-05
Pressure dew point · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Max. working pressure · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Power consumption · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Weight · Sourced · 1 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
130 lbs58.967 kgFrequency not stated · model
as printed: "Weight Empty"; 59 kg
unspecified
Source · OEM_SOURCE
D12 51 130 12 3/4 32 2" NPT 250 17.2 130 59
Retrieved 2026-10-20
Dimensions · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Reference working pressure · Sourced · 8 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
250 psig250 psigFrequency not stated · model
the pressure "Maximum capacity" is stated at (at 250 PSIG)
unspecified
Source · OEM_SOURCE
Maximum capacity: 231
Retrieved 2026-10-20
150 psig150 psigFrequency not stated · model
the pressure "Maximum capacity" is stated at (at 150 PSIG)
unspecified
Source · OEM_SOURCE
Maximum capacity: 144
Retrieved 2026-10-20
20 psig20 psigFrequency not stated · model
the pressure "Maximum capacity" is stated at (at 20 PSIG)
unspecified
Source · OEM_SOURCE
Maximum capacity: 30
Retrieved 2026-10-20
200 psig200 psigFrequency not stated · model
the pressure "Maximum capacity" is stated at (at 200 PSIG)
unspecified
Source · OEM_SOURCE
Maximum capacity: 187
Retrieved 2026-10-20
60 psig60 psigFrequency not stated · model
the pressure "Maximum capacity" is stated at (at 60 PSIG)
unspecified
Source · OEM_SOURCE
Maximum capacity: 65
Retrieved 2026-10-20
125 psig125 psigFrequency not stated · model
the pressure "Maximum capacity" is stated at (at 125 PSIG)
unspecified
Source · OEM_SOURCE
Maximum capacity: 122
Retrieved 2026-10-20
100 psig100 psigFrequency not stated · model
the pressure "Maximum capacity" is stated at (at 100 PSIG)
unspecified
Source · OEM_SOURCE
Maximum capacity: 100
Retrieved 2026-10-20
10 psig10 psigFrequency not stated · model
the pressure "Maximum capacity" is stated at (at 10 PSIG)
unspecified
Source · OEM_SOURCE
Maximum capacity: 22
Retrieved 2026-10-20

Operating-performance coverage

Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.

No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.

Document coverage

Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.

CategoryModel linksFamily linksPublic sources
Specifications10
Performance curves / test data00Not collected
Operation / service manuals00Not collected
Parts documentation00Not collected
Drawings / dimensions00Not collected
Product / family literature10
Other / unclassified00Not collected