One model, connected records

Van Air Systems → Van Air VME Series Oil Mist Eliminators → VME-10000

Manufacturer model: VME-10000 · OEM article / order number: Not collected · Equipment type: filter

Technology: Filtration / Air Treatment

Related applications: Food-Contact Air, Instrument Air, Plant Air, Spray + Finishing
Related industries: General Manufacturing, Pharmaceutical

These are technology associations. Check the operating point and process requirements to establish suitability for this model.

Compare coverage across this family

Specifications and evidence

19 stored observations · 19 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.

The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.

Rated capacity · Sourced · 9 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
5600 scfm9514.456 m3/hFrequency not stated · model
at 50 PSIG
standard
Source · OEM_SOURCE
Maximum capacity: 5600
Retrieved 2026-10-05
6500 scfm11043.57 m3/hFrequency not stated · model
at 60 PSIG
standard
Source · OEM_SOURCE
Maximum capacity: 6500
Retrieved 2026-10-05
7400 scfm12572.67 m3/hFrequency not stated · model
at 70 PSIG
standard
Source · OEM_SOURCE
Maximum capacity: 7400
Retrieved 2026-10-05
8300 scfm14101.78 m3/hFrequency not stated · model
at 80 PSIG
standard
Source · OEM_SOURCE
Maximum capacity: 8300
Retrieved 2026-10-05
10900 scfm18519.21 m3/hFrequency not stated · model
at 110 PSIG
standard
Source · OEM_SOURCE
Maximum capacity: 10900
Retrieved 2026-10-05
11700 scfm19878.42 m3/hFrequency not stated · model
at 120 PSIG
standard
Source · OEM_SOURCE
Maximum capacity: 11700
Retrieved 2026-10-05
12600 scfm21407.53 m3/hFrequency not stated · model
at 130 PSIG
standard
Source · OEM_SOURCE
Maximum capacity: 12600
Retrieved 2026-10-05
13500 scfm22936.63 m3/hFrequency not stated · model
at 140 PSIG
standard
Source · OEM_SOURCE
Maximum capacity: 13500
Retrieved 2026-10-05
14400 scfm24465.74 m3/hFrequency not stated · model
at 150 PSIG
standard
Source · OEM_SOURCE
Maximum capacity: 14400
Retrieved 2026-10-05
Max. working pressure · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Pressure drop · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Weight · Sourced · 1 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
3180 lbs1442.423 kgFrequency not stated · model
as printed: "Weight"; 1441 kg
unspecified
Source · OEM_SOURCE
EVME-10000 3180 1441
Retrieved 2026-10-20
Dimensions · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Reference working pressure · Sourced · 9 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
150 psig150 psigFrequency not stated · model
the pressure "Maximum capacity" is stated at (at 150 PSIG)
unspecified
Source · OEM_SOURCE
Maximum capacity: 14400
Retrieved 2026-10-20
60 psig60 psigFrequency not stated · model
the pressure "Maximum capacity" is stated at (at 60 PSIG)
unspecified
Source · OEM_SOURCE
Maximum capacity: 6500
Retrieved 2026-10-20
140 psig140 psigFrequency not stated · model
the pressure "Maximum capacity" is stated at (at 140 PSIG)
unspecified
Source · OEM_SOURCE
Maximum capacity: 13500
Retrieved 2026-10-20
80 psig80 psigFrequency not stated · model
the pressure "Maximum capacity" is stated at (at 80 PSIG)
unspecified
Source · OEM_SOURCE
Maximum capacity: 8300
Retrieved 2026-10-20
50 psig50 psigFrequency not stated · model
the pressure "Maximum capacity" is stated at (at 50 PSIG)
unspecified
Source · OEM_SOURCE
Maximum capacity: 5600
Retrieved 2026-10-20
130 psig130 psigFrequency not stated · model
the pressure "Maximum capacity" is stated at (at 130 PSIG)
unspecified
Source · OEM_SOURCE
Maximum capacity: 12600
Retrieved 2026-10-20
110 psig110 psigFrequency not stated · model
the pressure "Maximum capacity" is stated at (at 110 PSIG)
unspecified
Source · OEM_SOURCE
Maximum capacity: 10900
Retrieved 2026-10-20
70 psig70 psigFrequency not stated · model
the pressure "Maximum capacity" is stated at (at 70 PSIG)
unspecified
Source · OEM_SOURCE
Maximum capacity: 7400
Retrieved 2026-10-20
120 psig120 psigFrequency not stated · model
the pressure "Maximum capacity" is stated at (at 120 PSIG)
unspecified
Source · OEM_SOURCE
Maximum capacity: 11700
Retrieved 2026-10-20

Operating-performance coverage

Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.

No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.

Document coverage

Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.

CategoryModel linksFamily linksPublic sources
Specifications10
Performance curves / test data00Not collected
Operation / service manuals00Not collected
Parts documentation00Not collected
Drawings / dimensions00Not collected
Product / family literature10
Other / unclassified00Not collected