Data coverage & sources
The stored record for Van Air Systems VME-1500: specifications, configurations, documents, sources, and gaps.
One model, connected records
Van Air Systems → Van Air VME Series Oil Mist Eliminators → VME-1500
Manufacturer model: VME-1500 · OEM article / order number: Not collected · Equipment type: filter
Technology: Filtration / Air Treatment
Related applications: Food-Contact Air, Instrument Air, Plant Air, Spray + Finishing
Related industries: General Manufacturing, Pharmaceutical
These are technology associations. Check the operating point and process requirements to establish suitability for this model.
Compare coverage across this familySpecifications and evidence
23 stored observations · 23 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.
The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.
Rated capacity · Sourced · 11 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 840 scfm | 1427.168 m3/h | Frequency not stated · model at 50 PSIG standard | Source · OEM_SOURCEMaximum capacity: 840Retrieved 2026-10-05 |
| 975 scfm | 1656.535 m3/h | Frequency not stated · model at 60 PSIG standard | Source · OEM_SOURCEMaximum capacity: 975Retrieved 2026-10-05 |
| 1110 scfm | 1885.901 m3/h | Frequency not stated · model at 70 PSIG standard | Source · OEM_SOURCEMaximum capacity: 1110Retrieved 2026-10-05 |
| 1245 scfm | 2115.267 m3/h | Frequency not stated · model at 80 PSIG standard | Source · OEM_SOURCEMaximum capacity: 1245Retrieved 2026-10-05 |
| 1365 scfm | 2319.149 m3/h | Frequency not stated · model at 90 PSIG standard | Source · OEM_SOURCEMaximum capacity: 1365Retrieved 2026-10-05 |
| 1500 scfm | 2548.515 m3/h | Frequency not stated · model at 100 PSIG standard | Source · OEM_SOURCEMaximum capacity: 1500Retrieved 2026-10-05 |
| 1635 scfm | 2777.881 m3/h | Frequency not stated · model at 110 PSIG standard | Source · OEM_SOURCEMaximum capacity: 1635Retrieved 2026-10-05 |
| 1755 scfm | 2981.763 m3/h | Frequency not stated · model at 120 PSIG standard | Source · OEM_SOURCEMaximum capacity: 1755Retrieved 2026-10-05 |
| 1890 scfm | 3211.129 m3/h | Frequency not stated · model at 130 PSIG standard | Source · OEM_SOURCEMaximum capacity: 1890Retrieved 2026-10-05 |
| 2025 scfm | 3440.495 m3/h | Frequency not stated · model at 140 PSIG standard | Source · OEM_SOURCEMaximum capacity: 2025Retrieved 2026-10-05 |
| 2160 scfm | 3669.862 m3/h | Frequency not stated · model at 150 PSIG standard | Source · OEM_SOURCEMaximum capacity: 2160Retrieved 2026-10-05 |
Max. working pressure · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Pressure drop · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Weight · Sourced · 1 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 820 lbs | 371.9454 kg | Frequency not stated · model as printed: "Weight"; 372 kg unspecified | Source · OEM_SOURCEEVME-1500 820 372Retrieved 2026-10-20 |
Dimensions · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Reference working pressure · Sourced · 11 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 140 psig | 140 psig | Frequency not stated · model the pressure "Maximum capacity" is stated at (at 140 PSIG) unspecified | Source · OEM_SOURCEMaximum capacity: 2025Retrieved 2026-10-20 |
| 90 psig | 90 psig | Frequency not stated · model the pressure "Maximum capacity" is stated at (at 90 PSIG) unspecified | Source · OEM_SOURCEMaximum capacity: 1365Retrieved 2026-10-20 |
| 130 psig | 130 psig | Frequency not stated · model the pressure "Maximum capacity" is stated at (at 130 PSIG) unspecified | Source · OEM_SOURCEMaximum capacity: 1890Retrieved 2026-10-20 |
| 80 psig | 80 psig | Frequency not stated · model the pressure "Maximum capacity" is stated at (at 80 PSIG) unspecified | Source · OEM_SOURCEMaximum capacity: 1245Retrieved 2026-10-20 |
| 150 psig | 150 psig | Frequency not stated · model the pressure "Maximum capacity" is stated at (at 150 PSIG) unspecified | Source · OEM_SOURCEMaximum capacity: 2160Retrieved 2026-10-20 |
| 120 psig | 120 psig | Frequency not stated · model the pressure "Maximum capacity" is stated at (at 120 PSIG) unspecified | Source · OEM_SOURCEMaximum capacity: 1755Retrieved 2026-10-20 |
| 50 psig | 50 psig | Frequency not stated · model the pressure "Maximum capacity" is stated at (at 50 PSIG) unspecified | Source · OEM_SOURCEMaximum capacity: 840Retrieved 2026-10-20 |
| 100 psig | 100 psig | Frequency not stated · model the pressure "Maximum capacity" is stated at (at 100 PSIG) unspecified | Source · OEM_SOURCEMaximum capacity: 1500Retrieved 2026-10-20 |
| 60 psig | 60 psig | Frequency not stated · model the pressure "Maximum capacity" is stated at (at 60 PSIG) unspecified | Source · OEM_SOURCEMaximum capacity: 975Retrieved 2026-10-20 |
| 70 psig | 70 psig | Frequency not stated · model the pressure "Maximum capacity" is stated at (at 70 PSIG) unspecified | Source · OEM_SOURCEMaximum capacity: 1110Retrieved 2026-10-20 |
| 110 psig | 110 psig | Frequency not stated · model the pressure "Maximum capacity" is stated at (at 110 PSIG) unspecified | Source · OEM_SOURCEMaximum capacity: 1635Retrieved 2026-10-20 |
Operating-performance coverage
Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.
No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.
Document coverage
Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.
| Category | Model links | Family links | Public sources |
|---|---|---|---|
| Specifications | 1 | 0 |
|
| Performance curves / test data | 0 | 0 | Not collected |
| Operation / service manuals | 0 | 0 | Not collected |
| Parts documentation | 0 | 0 | Not collected |
| Drawings / dimensions | 0 | 0 | Not collected |
| Product / family literature | 1 | 0 |
|
| Other / unclassified | 0 | 0 | Not collected |