Find equipmentComparePartsManufacturersTechnologiesIndustriesApplicationsAsset trackingMy equipmentTalk to a specialist

Data coverage & sources

The stored record for Walker Filtration XM361MV: specifications, configurations, documents, sources, and gaps.

One model, connected records

Walker Filtration → Walker Filtration PRO MV data sheet → XM361MV

Manufacturer model: XM361MV · OEM article / order number: Not collected · Equipment type: filter

Technology: Filtration / Air Treatment

Related applications: Food-Contact Air, Instrument Air, Plant Air, Spray + Finishing
Related industries: General Manufacturing, Pharmaceutical

These are technology associations. Check the operating point and process requirements to establish suitability for this model.

Compare coverage across this family

Specifications and evidence

3 stored observations · 3 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.

The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.

Rated capacity · Sourced · 1 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
240 Nm³/hr240 m3/hFrequency not stated · model
Conditions not stated
normal
Source · OEM_SOURCE
Inlet flow rate: 240
Retrieved 2026-10-05
Max. working pressure · Sourced · 1 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
0.5 barg500 mbarFrequency not stated · model
Conditions not stated
unspecified
Source · OEM_VERIFIED
Max. working pressure: 0.5
Retrieved 2026-10-05
Pressure drop · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Weight · Sourced · 1 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
16.5 kg16.5 kgFrequency not stated · model
Conditions not stated
unspecified
Source · OEM_SOURCE
Weight: 16.5
Retrieved 2026-10-05
Dimensions · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Operating-performance coverage

Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.

No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.

Document coverage

Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.

CategoryModel linksFamily linksPublic sources
Specifications10
Performance curves / test data00Not collected
Operation / service manuals00Not collected
Parts documentation00Not collected
Drawings / dimensions00Not collected
Product / family literature00Not collected
Other / unclassified00Not collected