Find equipmentComparePartsManufacturersTechnologiesIndustriesApplicationsAsset trackingMy equipmentTalk to a specialist

Data coverage & sources

The stored record for BAUER Kompressoren GIB 23.7-37: specifications, configurations, documents, sources, and gaps.

One model, connected records

BAUER Kompressoren → BAUER GIB 23 series (90 bar) → GIB 23.7-37

Manufacturer model: GIB 23.7-37 · OEM article / order number: Not collected · Equipment type: compressor

Technology: Reciprocating

Compare coverage across this family

Specifications and evidence

21 stored observations · 0 pass the source policy at 50 Hz. Individual ratings do not establish flow at a requested pressure.

The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.

Free air delivery · Other conditions · 10 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
2200 l/min132 m3/h60 Hz · model
GIB 23 series | 25 to 90 bar | 60 Hz, Inlet pressure: 4 bar; (Effective free air delivery)
free air delivery
Source · OEM_SOURCE
different frequency
Capacity (Effective free air delivery): 2200
Retrieved 2026-10-03
132 m³/h132 m3/h60 Hz · model
GIB 23 series | 25 to 90 bar | 60 Hz, Inlet pressure: 4 bar; (Effective free air delivery)
free air delivery
Source · OEM_SOURCE
different frequency
Capacity (Effective free air delivery): 132
Retrieved 2026-10-03
3070 l/min184.2 m3/h60 Hz · model
GIB 23 series | 25 to 90 bar | 60 Hz, Inlet pressure: 6 bar; (Effective free air delivery)
free air delivery
Source · OEM_SOURCE
different frequency
Capacity (Effective free air delivery): 3070
Retrieved 2026-10-03
184 m³/h184 m3/h60 Hz · model
GIB 23 series | 25 to 90 bar | 60 Hz, Inlet pressure: 6 bar; (Effective free air delivery)
free air delivery
Source · OEM_SOURCE
different frequency
Capacity (Effective free air delivery): 184
Retrieved 2026-10-03
3950 l/min237 m3/h60 Hz · model
GIB 23 series | 25 to 90 bar | 60 Hz, Inlet pressure: 8 bar; (Effective free air delivery)
free air delivery
Source · OEM_SOURCE
different frequency
Capacity (Effective free air delivery): 3950
Retrieved 2026-10-03
237 m³/h237 m3/h60 Hz · model
GIB 23 series | 25 to 90 bar | 60 Hz, Inlet pressure: 8 bar; (Effective free air delivery)
free air delivery
Source · OEM_SOURCE
different frequency
Capacity (Effective free air delivery): 237
Retrieved 2026-10-03
4850 l/min291 m3/h60 Hz · model
GIB 23 series | 25 to 90 bar | 60 Hz, Inlet pressure: 10 bar; (Effective free air delivery)
free air delivery
Source · OEM_SOURCE
different frequency
Capacity (Effective free air delivery): 4850
Retrieved 2026-10-03
291 m³/h291 m3/h60 Hz · model
GIB 23 series | 25 to 90 bar | 60 Hz, Inlet pressure: 10 bar; (Effective free air delivery)
free air delivery
Source · OEM_SOURCE
different frequency
Capacity (Effective free air delivery): 291
Retrieved 2026-10-03
5750 l/min345 m3/h60 Hz · model
GIB 23 series | 25 to 90 bar | 60 Hz, Inlet pressure: 12 bar; (Effective free air delivery)
free air delivery
Source · OEM_SOURCE
different frequency
Capacity (Effective free air delivery): 5750
Retrieved 2026-10-03
345 m³/h345 m3/h60 Hz · model
GIB 23 series | 25 to 90 bar | 60 Hz, Inlet pressure: 12 bar; (Effective free air delivery)
free air delivery
Source · OEM_SOURCE
different frequency
Capacity (Effective free air delivery): 345
Retrieved 2026-10-03
Max. pressure · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Motor power · Other conditions · 5 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
37 kW37 kW60 Hz · model
GIB 23 series | 25 to 90 bar | 60 Hz, Inlet pressure: 4 bar
unspecified
Source · OEM_SOURCE
different frequency
Motor power: 37
Retrieved 2026-10-03
37 kW37 kW60 Hz · model
GIB 23 series | 25 to 90 bar | 60 Hz, Inlet pressure: 6 bar
unspecified
Source · OEM_SOURCE
different frequency
Motor power: 37
Retrieved 2026-10-03
37 kW37 kW60 Hz · model
GIB 23 series | 25 to 90 bar | 60 Hz, Inlet pressure: 8 bar
unspecified
Source · OEM_SOURCE
different frequency
Motor power: 37
Retrieved 2026-10-03
37 kW37 kW60 Hz · model
GIB 23 series | 25 to 90 bar | 60 Hz, Inlet pressure: 10 bar
unspecified
Source · OEM_SOURCE
different frequency
Motor power: 37
Retrieved 2026-10-03
37 kW37 kW60 Hz · model
GIB 23 series | 25 to 90 bar | 60 Hz, Inlet pressure: 12 bar
unspecified
Source · OEM_SOURCE
different frequency
Motor power: 37
Retrieved 2026-10-03
Speed · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Noise level · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Weight · Other conditions · 5 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
1050 kg1050 kg60 Hz · model
GIB 23 series | 25 to 90 bar | 60 Hz, Inlet pressure: 4 bar; (Net weight approx.)
unspecified
Source · OEM_SOURCE
different frequency
Weight (Net weight approx.): 1050
Retrieved 2026-10-03
1050 kg1050 kg60 Hz · model
GIB 23 series | 25 to 90 bar | 60 Hz, Inlet pressure: 6 bar; (Net weight approx.)
unspecified
Source · OEM_SOURCE
different frequency
Weight (Net weight approx.): 1050
Retrieved 2026-10-03
1050 kg1050 kg60 Hz · model
GIB 23 series | 25 to 90 bar | 60 Hz, Inlet pressure: 8 bar; (Net weight approx.)
unspecified
Source · OEM_SOURCE
different frequency
Weight (Net weight approx.): 1050
Retrieved 2026-10-03
1050 kg1050 kg60 Hz · model
GIB 23 series | 25 to 90 bar | 60 Hz, Inlet pressure: 10 bar; (Net weight approx.)
unspecified
Source · OEM_SOURCE
different frequency
Weight (Net weight approx.): 1050
Retrieved 2026-10-03
1050 kg1050 kg60 Hz · model
GIB 23 series | 25 to 90 bar | 60 Hz, Inlet pressure: 12 bar; (Net weight approx.)
unspecified
Source · OEM_SOURCE
different frequency
Weight (Net weight approx.): 1050
Retrieved 2026-10-03
Dimensions · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Inlet connection · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Outlet connection · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Reference working pressure · Other conditions · 1 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
25 to 90 bar25000 mbar60 Hz · model
the pressure "Capacity (Effective free air delivery)" is stated at (GIB 23 series | 25 to 90 bar | 60 Hz, Inlet pressure: 4 bar; (Effective free air delivery))
free air delivery
Source · OEM_SOURCE
different frequency
Capacity (Effective free air delivery): 2200
Retrieved 2026-10-20

Operating-performance coverage

Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.

No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.

Document coverage

Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.

CategoryModel linksFamily linksPublic sources
Specifications00Not collected
Performance curves / test data00Not collected
Operation / service manuals00Not collected
Parts documentation00Not collected
Drawings / dimensions00Not collected
Product / family literature00Not collected
Other / unclassified00Not collected