Data coverage & sources
The stored record for BAUER Kompressoren GIB 52.12-250: specifications, configurations, documents, sources, and gaps.
One model, connected records
BAUER Kompressoren → BAUER GIB 52 series → GIB 52.12-250
Manufacturer model: GIB 52.12-250 · OEM article / order number: Not collected · Equipment type: compressor
Technology: Reciprocating
Compare coverage across this familySpecifications and evidence
17 stored observations · 17 pass the source policy at 50 Hz. Individual ratings do not establish flow at a requested pressure.
The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.
Free air delivery · Sourced · 8 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 10800 l/min | 648 m3/h | 50 Hz · model GIB 52 series | 90 to 365 bar | 50 Hz, Inlet pressure: 4.5 bar; (Effective free air delivery) free air delivery | Source · OEM_SOURCECapacity (Effective free air delivery): 10800Retrieved 2026-10-03 |
| 648 m³/h | 648 m3/h | 50 Hz · model GIB 52 series | 90 to 365 bar | 50 Hz, Inlet pressure: 4.5 bar; (Effective free air delivery) free air delivery | Source · OEM_SOURCECapacity (Effective free air delivery): 648Retrieved 2026-10-03 |
| 13800 l/min | 828 m3/h | 50 Hz · model GIB 52 series | 90 to 365 bar | 50 Hz, Inlet pressure: 6 bar; (Effective free air delivery) free air delivery | Source · OEM_SOURCECapacity (Effective free air delivery): 13800Retrieved 2026-10-03 |
| 828 m³/h | 828 m3/h | 50 Hz · model GIB 52 series | 90 to 365 bar | 50 Hz, Inlet pressure: 6 bar; (Effective free air delivery) free air delivery | Source · OEM_SOURCECapacity (Effective free air delivery): 828Retrieved 2026-10-03 |
| 17700 l/min | 1062 m3/h | 50 Hz · model GIB 52 series | 90 to 365 bar | 50 Hz, Inlet pressure: 8 bar; (Effective free air delivery) free air delivery | Source · OEM_SOURCECapacity (Effective free air delivery): 17700Retrieved 2026-10-03 |
| 1062 m³/h | 1062 m3/h | 50 Hz · model GIB 52 series | 90 to 365 bar | 50 Hz, Inlet pressure: 8 bar; (Effective free air delivery) free air delivery | Source · OEM_SOURCECapacity (Effective free air delivery): 1062Retrieved 2026-10-03 |
| 21700 l/min | 1302 m3/h | 50 Hz · model GIB 52 series | 90 to 365 bar | 50 Hz, Inlet pressure: 10 bar; (Effective free air delivery) free air delivery | Source · OEM_SOURCECapacity (Effective free air delivery): 21700Retrieved 2026-10-03 |
| 1302 m³/h | 1302 m3/h | 50 Hz · model GIB 52 series | 90 to 365 bar | 50 Hz, Inlet pressure: 10 bar; (Effective free air delivery) free air delivery | Source · OEM_SOURCECapacity (Effective free air delivery): 1302Retrieved 2026-10-03 |
Max. pressure · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Motor power · Sourced · 4 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 250 kW | 250 kW | 50 Hz · model GIB 52 series | 90 to 365 bar | 50 Hz, Inlet pressure: 4.5 bar unspecified | Source · OEM_SOURCEMotor power: 250Retrieved 2026-10-03 |
| 250 kW | 250 kW | 50 Hz · model GIB 52 series | 90 to 365 bar | 50 Hz, Inlet pressure: 6 bar unspecified | Source · OEM_SOURCEMotor power: 250Retrieved 2026-10-03 |
| 250 kW | 250 kW | 50 Hz · model GIB 52 series | 90 to 365 bar | 50 Hz, Inlet pressure: 8 bar unspecified | Source · OEM_SOURCEMotor power: 250Retrieved 2026-10-03 |
| 315 kW | 315 kW | 50 Hz · model GIB 52 series | 90 to 365 bar | 50 Hz, Inlet pressure: 10 bar unspecified | Source · OEM_SOURCEMotor power: 315Retrieved 2026-10-03 |
Speed · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Noise level · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Weight · Sourced · 4 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 5500 kg | 5500 kg | 50 Hz · model GIB 52 series | 90 to 365 bar | 50 Hz, Inlet pressure: 4.5 bar; (Net weight approx.) unspecified | Source · OEM_SOURCEWeight (Net weight approx.): 5500Retrieved 2026-10-03 |
| 5500 kg | 5500 kg | 50 Hz · model GIB 52 series | 90 to 365 bar | 50 Hz, Inlet pressure: 6 bar; (Net weight approx.) unspecified | Source · OEM_SOURCEWeight (Net weight approx.): 5500Retrieved 2026-10-03 |
| 5500 kg | 5500 kg | 50 Hz · model GIB 52 series | 90 to 365 bar | 50 Hz, Inlet pressure: 8 bar; (Net weight approx.) unspecified | Source · OEM_SOURCEWeight (Net weight approx.): 5500Retrieved 2026-10-03 |
| 6000 kg | 6000 kg | 50 Hz · model GIB 52 series | 90 to 365 bar | 50 Hz, Inlet pressure: 10 bar; (Net weight approx.) unspecified | Source · OEM_SOURCEWeight (Net weight approx.): 6000Retrieved 2026-10-03 |
Dimensions · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Inlet connection · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Outlet connection · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Reference working pressure · Sourced · 1 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 90 to 365 bar | 90000 mbar | 50 Hz · model the pressure "Capacity (Effective free air delivery)" is stated at (GIB 52 series | 90 to 365 bar | 50 Hz, Inlet pressure: 4.5 bar; (Effective free air delivery)) free air delivery | Source · OEM_SOURCECapacity (Effective free air delivery): 10800Retrieved 2026-10-20 |
Operating-performance coverage
Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.
No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.
Document coverage
Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.
| Category | Model links | Family links | Public sources |
|---|---|---|---|
| Specifications | 0 | 0 | Not collected |
| Performance curves / test data | 0 | 0 | Not collected |
| Operation / service manuals | 0 | 0 | Not collected |
| Parts documentation | 0 | 0 | Not collected |
| Drawings / dimensions | 0 | 0 | Not collected |
| Product / family literature | 0 | 0 | Not collected |
| Other / unclassified | 0 | 0 | Not collected |