Find equipmentComparePartsManufacturersTechnologiesIndustriesApplicationsAsset trackingMy equipmentTalk to a specialist

Data coverage & sources

The stored record for Busch COBRA DX 2000 A PLUS: specifications, configurations, documents, sources, and gaps.

One model, connected records

Busch → COBRA DX 2000 A PLUS → COBRA DX 2000 A PLUS

Manufacturer model: COBRA DX 2000 A PLUS · OEM article / order number: Not collected · Equipment type: vacuum pump

Technology: Dry Screw

Related applications: Degassing, Drying, Process Vacuum
Related industries: Chemical, Oil + Gas, Pharmaceutical, Semiconductor

These are technology associations. Check the operating point and process requirements to establish suitability for this model.

Compare coverage across this family

Specifications and evidence

27 stored observations · 9 pass the source policy at 50 Hz. Individual ratings do not establish flow at a requested pressure.

The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.

Pumping speed · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
1900 m³/h m³/h1900 m3/h50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_VERIFIED
Nominal pumping speed: 1900 m³/h
Retrieved 2026-10-01
1900 m³/h m³/h1900 m3/h60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_VERIFIED
different frequency
Nominal pumping speed: 1900 m³/h
Retrieved 2026-10-01
1118.2 ACFM ACFM1899.833 m3/h60 Hz · model
US 60 Hz
actual inlet
Source · OEM_SOURCE
different frequency
Nominal pumping speed: 1118.2 ACFM
Retrieved 2026-10-01
Ultimate pressure · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
≤ 0.01 hPa (mbar) hPa (mbar)0.01 mbar50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_VERIFIED
Ultimate pressure: ≤ 0.01 hPa (mbar)
Retrieved 2026-10-01
≤ 0.01 hPa (mbar) hPa (mbar)0.01 mbar60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_VERIFIED
different frequency
Ultimate pressure: ≤ 0.01 hPa (mbar)
Retrieved 2026-10-01
≤ 0.0075 Torr Torr0.01 mbar60 Hz · model
US 60 Hz
unspecified
Source · OEM_SOURCE
different frequency
Ultimate pressure: ≤ 0.0075 Torr
Retrieved 2026-10-01
Motor power · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
2 x 18.5 kW — 50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
Nominal motor rating: 2 x 18.5 kW
Retrieved 2026-10-01
2 x 18.5 kW — 60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_SOURCE
different frequency
Nominal motor rating: 2 x 18.5 kW
Retrieved 2026-10-01
2 x 25 hp — 60 Hz · model
US 60 Hz
unspecified
Source · OEM_SOURCE
different frequency
Nominal motor rating: 2 x 25 hp
Retrieved 2026-10-01
Speed · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
4320 min⁻¹ min⁻¹4320 rpm50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_VERIFIED
Nominal motor speed: 4320 min⁻¹
Retrieved 2026-10-01
4320 min⁻¹ min⁻¹4320 rpm60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_VERIFIED
different frequency
Nominal motor speed: 4320 min⁻¹
Retrieved 2026-10-01
4320 rpm rpm4320 rpm60 Hz · model
US 60 Hz
unspecified
Source · OEM_SOURCE
different frequency
Nominal motor speed: 4320 rpm
Retrieved 2026-10-01
Noise level · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
≤ 76 dB(A) dB(A)76 dB(A)50 Hz · model
ISO 50 Hz; (ISO 2151), KpA = 3 dB
unspecified
Source · OEM_VERIFIED
Sound pressure level (ISO 2151), KpA = 3 dB: ≤ 76 dB(A)
Retrieved 2026-10-01
≤ 76 dB(A) dB(A)76 dB(A)60 Hz · model
ISO 60 Hz; (ISO 2151), KpA = 3 dB
unspecified
Source · OEM_VERIFIED
different frequency
Sound pressure level (ISO 2151), KpA = 3 dB: ≤ 76 dB(A)
Retrieved 2026-10-01
≤ 76 dB(A) dB(A)76 dB(A)60 Hz · model
US 60 Hz; (ISO 2151), KpA = 3 dB
unspecified
Source · OEM_VERIFIED
different frequency
Sound pressure level (ISO 2151), KpA = 3 dB: ≤ 76 dB(A)
Retrieved 2026-10-01
Weight · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
2750 kg kg2750 kg50 Hz · model
ISO 50 Hz; approx.
unspecified
Source · OEM_VERIFIED
Weight approx.: 2750 kg
Retrieved 2026-10-01
2750 kg kg2750 kg60 Hz · model
ISO 60 Hz; approx.
unspecified
Source · OEM_VERIFIED
different frequency
Weight approx.: 2750 kg
Retrieved 2026-10-01
6062 Lbs. Lbs.2749.675 kg60 Hz · model
US 60 Hz; approx.
unspecified
Source · OEM_SOURCE
different frequency
Weight approx.: 6062 Lbs.
Retrieved 2026-10-01
Dimensions · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
2035 x 983 x 1950 mm mm— 50 Hz · model
ISO 50 Hz; (L x W x H)
unspecified
Source · OEM_SOURCE
Dimensions (L x W x H): 2035 x 983 x 1950 mm
Retrieved 2026-10-01
2035 x 983 x 1950 mm mm— 60 Hz · model
ISO 60 Hz; (L x W x H)
unspecified
Source · OEM_SOURCE
different frequency
Dimensions (L x W x H): 2035 x 983 x 1950 mm
Retrieved 2026-10-01
80.1 x 38.7 x 76.8 inches inches— 60 Hz · model
US 60 Hz; (L x W x H)
unspecified
Source · OEM_SOURCE
different frequency
Dimensions (L x W x H): 80.1 x 38.7 x 76.8 inches
Retrieved 2026-10-01
Inlet connection · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
DN 160 ISO-K — 50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
Gas inlet: DN 160 ISO-K
Retrieved 2026-10-01
DN 160 ISO-K — 60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_SOURCE
different frequency
Gas inlet: DN 160 ISO-K
Retrieved 2026-10-01
DN 160 ISO-K — 60 Hz · model
US 60 Hz
unspecified
Source · OEM_SOURCE
different frequency
Gas inlet: DN 160 ISO-K
Retrieved 2026-10-01
Outlet connection · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
DN 100 ISO-K — 50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
Gas outlet: DN 100 ISO-K
Retrieved 2026-10-01
DN 100 ISO-K — 60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_SOURCE
different frequency
Gas outlet: DN 100 ISO-K
Retrieved 2026-10-01
DN 100 ISO-K — 60 Hz · model
US 60 Hz
unspecified
Source · OEM_SOURCE
different frequency
Gas outlet: DN 100 ISO-K
Retrieved 2026-10-01

Operating-performance coverage

Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.

No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.

Document coverage

Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.

CategoryModel linksFamily linksPublic sources
Specifications20
Performance curves / test data00Not collected
Operation / service manuals20
Parts documentation00Not collected
Drawings / dimensions00Not collected
Product / family literature00Not collected
Other / unclassified00Not collected