Data coverage & sources
The stored record for Busch COBRA DX 2000 A PLUS: specifications, configurations, documents, sources, and gaps.
One model, connected records
Busch → COBRA DX 2000 A PLUS → COBRA DX 2000 A PLUS
Manufacturer model: COBRA DX 2000 A PLUS · OEM article / order number: Not collected · Equipment type: vacuum pump
Technology: Dry Screw
Related applications: Degassing, Drying, Process Vacuum
Related industries: Chemical, Oil + Gas, Pharmaceutical, Semiconductor
These are technology associations. Check the operating point and process requirements to establish suitability for this model.
Compare coverage across this familySpecifications and evidence
27 stored observations · 9 pass the source policy at 50 Hz. Individual ratings do not establish flow at a requested pressure.
The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.
Pumping speed · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 1900 m³/h m³/h | 1900 m3/h | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_VERIFIEDNominal pumping speed: 1900 m³/hRetrieved 2026-10-01 |
| 1900 m³/h m³/h | 1900 m3/h | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_VERIFIED different frequency Nominal pumping speed: 1900 m³/hRetrieved 2026-10-01 |
| 1118.2 ACFM ACFM | 1899.833 m3/h | 60 Hz · model US 60 Hz actual inlet | Source · OEM_SOURCE different frequency Nominal pumping speed: 1118.2 ACFMRetrieved 2026-10-01 |
Ultimate pressure · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| ≤ 0.01 hPa (mbar) hPa (mbar) | 0.01 mbar | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_VERIFIEDUltimate pressure: ≤ 0.01 hPa (mbar)Retrieved 2026-10-01 |
| ≤ 0.01 hPa (mbar) hPa (mbar) | 0.01 mbar | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_VERIFIED different frequency Ultimate pressure: ≤ 0.01 hPa (mbar)Retrieved 2026-10-01 |
| ≤ 0.0075 Torr Torr | 0.01 mbar | 60 Hz · model US 60 Hz unspecified | Source · OEM_SOURCE different frequency Ultimate pressure: ≤ 0.0075 TorrRetrieved 2026-10-01 |
Motor power · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 2 x 18.5 kW | — | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_SOURCENominal motor rating: 2 x 18.5 kWRetrieved 2026-10-01 |
| 2 x 18.5 kW | — | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_SOURCE different frequency Nominal motor rating: 2 x 18.5 kWRetrieved 2026-10-01 |
| 2 x 25 hp | — | 60 Hz · model US 60 Hz unspecified | Source · OEM_SOURCE different frequency Nominal motor rating: 2 x 25 hpRetrieved 2026-10-01 |
Speed · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 4320 min⁻¹ min⁻¹ | 4320 rpm | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_VERIFIEDNominal motor speed: 4320 min⁻¹Retrieved 2026-10-01 |
| 4320 min⁻¹ min⁻¹ | 4320 rpm | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_VERIFIED different frequency Nominal motor speed: 4320 min⁻¹Retrieved 2026-10-01 |
| 4320 rpm rpm | 4320 rpm | 60 Hz · model US 60 Hz unspecified | Source · OEM_SOURCE different frequency Nominal motor speed: 4320 rpmRetrieved 2026-10-01 |
Noise level · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| ≤ 76 dB(A) dB(A) | 76 dB(A) | 50 Hz · model ISO 50 Hz; (ISO 2151), KpA = 3 dB unspecified | Source · OEM_VERIFIEDSound pressure level (ISO 2151), KpA = 3 dB: ≤ 76 dB(A)Retrieved 2026-10-01 |
| ≤ 76 dB(A) dB(A) | 76 dB(A) | 60 Hz · model ISO 60 Hz; (ISO 2151), KpA = 3 dB unspecified | Source · OEM_VERIFIED different frequency Sound pressure level (ISO 2151), KpA = 3 dB: ≤ 76 dB(A)Retrieved 2026-10-01 |
| ≤ 76 dB(A) dB(A) | 76 dB(A) | 60 Hz · model US 60 Hz; (ISO 2151), KpA = 3 dB unspecified | Source · OEM_VERIFIED different frequency Sound pressure level (ISO 2151), KpA = 3 dB: ≤ 76 dB(A)Retrieved 2026-10-01 |
Weight · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 2750 kg kg | 2750 kg | 50 Hz · model ISO 50 Hz; approx. unspecified | Source · OEM_VERIFIEDWeight approx.: 2750 kgRetrieved 2026-10-01 |
| 2750 kg kg | 2750 kg | 60 Hz · model ISO 60 Hz; approx. unspecified | Source · OEM_VERIFIED different frequency Weight approx.: 2750 kgRetrieved 2026-10-01 |
| 6062 Lbs. Lbs. | 2749.675 kg | 60 Hz · model US 60 Hz; approx. unspecified | Source · OEM_SOURCE different frequency Weight approx.: 6062 Lbs.Retrieved 2026-10-01 |
Dimensions · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 2035 x 983 x 1950 mm mm | — | 50 Hz · model ISO 50 Hz; (L x W x H) unspecified | Source · OEM_SOURCEDimensions (L x W x H): 2035 x 983 x 1950 mmRetrieved 2026-10-01 |
| 2035 x 983 x 1950 mm mm | — | 60 Hz · model ISO 60 Hz; (L x W x H) unspecified | Source · OEM_SOURCE different frequency Dimensions (L x W x H): 2035 x 983 x 1950 mmRetrieved 2026-10-01 |
| 80.1 x 38.7 x 76.8 inches inches | — | 60 Hz · model US 60 Hz; (L x W x H) unspecified | Source · OEM_SOURCE different frequency Dimensions (L x W x H): 80.1 x 38.7 x 76.8 inchesRetrieved 2026-10-01 |
Inlet connection · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| DN 160 ISO-K | — | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_SOURCEGas inlet: DN 160 ISO-KRetrieved 2026-10-01 |
| DN 160 ISO-K | — | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_SOURCE different frequency Gas inlet: DN 160 ISO-KRetrieved 2026-10-01 |
| DN 160 ISO-K | — | 60 Hz · model US 60 Hz unspecified | Source · OEM_SOURCE different frequency Gas inlet: DN 160 ISO-KRetrieved 2026-10-01 |
Outlet connection · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| DN 100 ISO-K | — | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_SOURCEGas outlet: DN 100 ISO-KRetrieved 2026-10-01 |
| DN 100 ISO-K | — | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_SOURCE different frequency Gas outlet: DN 100 ISO-KRetrieved 2026-10-01 |
| DN 100 ISO-K | — | 60 Hz · model US 60 Hz unspecified | Source · OEM_SOURCE different frequency Gas outlet: DN 100 ISO-KRetrieved 2026-10-01 |
Operating-performance coverage
Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.
No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.
Document coverage
Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.
| Category | Model links | Family links | Public sources |
|---|---|---|---|
| Specifications | 2 | 0 |
|
| Performance curves / test data | 0 | 0 | Not collected |
| Operation / service manuals | 2 | 0 |
|
| Parts documentation | 0 | 0 | Not collected |
| Drawings / dimensions | 0 | 0 | Not collected |
| Product / family literature | 0 | 0 | Not collected |
| Other / unclassified | 0 | 0 | Not collected |