Find equipmentComparePartsManufacturersTechnologiesIndustriesApplicationsAsset trackingMy equipmentTalk to a specialist

Data coverage & sources

The stored record for Busch DOLPHIN VX 0030 A Partial Recirculation: specifications, configurations, documents, sources, and gaps.

One model, connected records

Busch → DOLPHIN VX 0030/0055 A Partial Recirculation → DOLPHIN VX 0030 A Partial Recirculation

Manufacturer model: DOLPHIN VX 0030 A Partial Recirculation · OEM article / order number: Not collected · Equipment type: vacuum pump

Technology: Liquid Ring

Related applications: Degassing, Drying, Process Vacuum
Related industries: Chemical, Food + Beverage, Mining, Oil + Gas, Pharmaceutical, Plastics, Power Generation, Pulp + Paper, Water + Wastewater

These are technology associations. Check the operating point and process requirements to establish suitability for this model.

Compare coverage across this family

Specifications and evidence

27 stored observations · 17 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.

The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.

Pumping speed · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
24 m³/h m³/h24 m3/h50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
different frequency
Nominal pumping speed: 24 m³/h
Retrieved 2026-10-01
31 m³/h m³/h31 m3/h60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_VERIFIED
Nominal pumping speed: 31 m³/h
Retrieved 2026-10-01
18 ACFM ACFM30.5822 m3/h60 Hz · model
US 60 Hz
actual inlet
Source · OEM_SOURCE
Nominal pumping speed: 18 ACFM
Retrieved 2026-10-01
Ultimate pressure · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
33 hPa (mbar) hPa (mbar)33 mbar50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_VERIFIED
different frequency
Ultimate pressure: 33 hPa (mbar)
Retrieved 2026-10-01
33 hPa (mbar) hPa (mbar)33 mbar60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_VERIFIED
Ultimate pressure: 33 hPa (mbar)
Retrieved 2026-10-01
25 Torr Torr33.3305 mbar60 Hz · model
US 60 Hz
unspecified
Source · OEM_SOURCE
Ultimate pressure: 25 Torr
Retrieved 2026-10-01
Motor power · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
1.1 kW kW1.1 kW50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
different frequency
Nominal motor rating: 1.1 kW
Retrieved 2026-10-01
1.5 kW kW1.5 kW60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_VERIFIED
Nominal motor rating: 1.5 kW
Retrieved 2026-10-01
2.0 hp hp1.4914 kW60 Hz · model
US 60 Hz
unspecified
Source · OEM_SOURCE
Nominal motor rating: 2.0 hp
Retrieved 2026-10-01
Speed · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
2900 min⁻¹ min⁻¹2900 rpm50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
different frequency
Nominal motor speed: 2900 min⁻¹
Retrieved 2026-10-01
3500 min⁻¹ min⁻¹3500 rpm60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_SOURCE
Nominal motor speed: 3500 min⁻¹
Retrieved 2026-10-01
Noise level · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
≤ 70 dB(A) dB(A)70 dB(A)50 Hz · model
ISO 50 Hz; (ISO 3744), 1 m distance, at medium load
unspecified
Source · OEM_SOURCE
different frequency
Sound pressure level (ISO 3744), 1 m distance, at medium load: ≤ 70 dB(A)
Retrieved 2026-10-01
≤ 70 dB(A) dB(A)70 dB(A)60 Hz · model
ISO 60 Hz; (ISO 3744), 1 m distance, at medium load
unspecified
Source · OEM_SOURCE
Sound pressure level (ISO 3744), 1 m distance, at medium load: ≤ 70 dB(A)
Retrieved 2026-10-01
Weight · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
75 kg kg75 kg50 Hz · model
ISO 50 Hz; approx.
unspecified
Source · OEM_SOURCE
different frequency
Weight approx.: 75 kg
Retrieved 2026-10-01
83 kg kg83 kg60 Hz · model
ISO 60 Hz; approx.
unspecified
Source · OEM_VERIFIED
Weight approx.: 83 kg
Retrieved 2026-10-01
183 Lbs. Lbs.83.0073 kg60 Hz · model
US 60 Hz; approx.
unspecified
Source · OEM_SOURCE
Weight approx.: 183 Lbs.
Retrieved 2026-10-01
Dimensions · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
540 x 550 x 570 mm mm— 50 Hz · model
ISO 50 Hz; (L x W x H)
unspecified
Source · OEM_SOURCE
different frequency
Dimensions (L x W x H): 540 x 550 x 570 mm
Retrieved 2026-10-01
540 x 550 x 570 mm mm— 60 Hz · model
ISO 60 Hz; (L x W x H)
unspecified
Source · OEM_SOURCE
Dimensions (L x W x H): 540 x 550 x 570 mm
Retrieved 2026-10-01
21.3 x 21.7 x 22.4 inches inches— 60 Hz · model
US 60 Hz; (L x W x H)
unspecified
Source · OEM_SOURCE
Dimensions (L x W x H): 21.3 x 21.7 x 22.4 inches
Retrieved 2026-10-01
Inlet connection · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
G 1" — 50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
different frequency
Gas inlet: G 1"
Retrieved 2026-10-01
G 1" — 60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_SOURCE
Gas inlet: G 1"
Retrieved 2026-10-01
G1" — 60 Hz · model
US 60 Hz
unspecified
Source · OEM_SOURCE
Gas inlet: G1"
Retrieved 2026-10-01
Outlet connection · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
R 2" — 50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
different frequency
Gas outlet: R 2"
Retrieved 2026-10-01
R 2" — 60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_SOURCE
Gas outlet: R 2"
Retrieved 2026-10-01
R2" — 60 Hz · model
US 60 Hz
unspecified
Source · OEM_SOURCE
Gas outlet: R2"
Retrieved 2026-10-01
Max. overpressure · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
0.5 bar(g) bar(g)— 50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
different frequency
Max. overpressure: 0.5 bar(g)
Retrieved 2026-10-01
0.5 bar(g) bar(g)— 60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_SOURCE
Max. overpressure: 0.5 bar(g)
Retrieved 2026-10-01

Operating-performance coverage

Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.

No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.

Document coverage

Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.

CategoryModel linksFamily linksPublic sources
Specifications20
Performance curves / test data00Not collected
Operation / service manuals10
Parts documentation00Not collected
Drawings / dimensions00Not collected
Product / family literature00Not collected
Other / unclassified00Not collected