Find equipmentComparePartsManufacturersTechnologiesIndustriesApplicationsAsset trackingMy equipmentTalk to a specialist

Data coverage & sources

The stored record for Busch PANDA WZ 0500 B: specifications, configurations, documents, sources, and gaps.

One model, connected records

Busch → PANDA WZ 0250–2400 A/B → PANDA WZ 0500 B

Manufacturer model: PANDA WZ 0500 B · OEM article / order number: Not collected · Equipment type: booster

Technology: Roots / Booster

Related applications: Leak Testing, Process Vacuum
Related industries: Automotive, Chemical, Metalworking, Oil + Gas, Power Generation, Semiconductor

These are technology associations. Check the operating point and process requirements to establish suitability for this model.

Compare coverage across this family

Specifications and evidence

36 stored observations · 11 pass the source policy at 50 Hz. Individual ratings do not establish flow at a requested pressure.

The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.

Pumping speed · Conflicting values · 6 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
525 m³/h m³/h525 m3/h50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
Nominal pumping speed: 525 m³/h
Retrieved 2026-10-01
464 m³/h m³/h464 m3/h50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
Pumping speed: 464 m³/h
Retrieved 2026-10-01
630 m³/h m³/h630 m3/h60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_VERIFIED
different frequency
Nominal pumping speed: 630 m³/h
Retrieved 2026-10-01
560 m³/h m³/h560 m3/h60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_VERIFIED
different frequency
Pumping speed: 560 m³/h
Retrieved 2026-10-01
370.8 ACFM ACFM629.9929 m3/h60 Hz · model
US 60 Hz
actual inlet
Source · OEM_VERIFIED
different frequency
Nominal pumping speed: 370.8 ACFM
Retrieved 2026-10-01
329.6 ACFM ACFM559.9937 m3/h60 Hz · model
US 60 Hz
actual inlet
Source · OEM_VERIFIED
different frequency
Pumping speed: 329.6 ACFM
Retrieved 2026-10-01
Ultimate pressure · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Motor power · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
4.0 kW kW4 kW50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
Nominal motor rating: 4.0 kW
Retrieved 2026-10-01
4.4 kW kW4.4 kW60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_VERIFIED
different frequency
Nominal motor rating: 4.4 kW
Retrieved 2026-10-01
5.9 hp hp4.3996 kW60 Hz · model
US 60 Hz
unspecified
Source · OEM_VERIFIED
different frequency
Nominal motor rating: 5.9 hp
Retrieved 2026-10-01
Speed · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
3000 min⁻¹ min⁻¹3000 rpm50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
Nominal motor speed: 3000 min⁻¹
Retrieved 2026-10-01
3600 min⁻¹ min⁻¹3600 rpm60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_VERIFIED
different frequency
Nominal motor speed: 3600 min⁻¹
Retrieved 2026-10-01
3600 RPM RPM3600 rpm60 Hz · model
US 60 Hz
unspecified
Source · OEM_VERIFIED
different frequency
Nominal motor speed: 3600 RPM
Retrieved 2026-10-01
Noise level · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Weight · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
175 kg kg175 kg50 Hz · model
ISO 50 Hz; approx.
unspecified
Source · OEM_VERIFIED
Weight approx.: 175 kg
Retrieved 2026-10-01
175 kg kg175 kg60 Hz · model
ISO 60 Hz; approx.
unspecified
Source · OEM_VERIFIED
different frequency
Weight approx.: 175 kg
Retrieved 2026-10-01
385 Lbs. Lbs.174.6329 kg60 Hz · model
US 60 Hz; approx.
unspecified
Source · OEM_VERIFIED
different frequency
Weight approx.: 385 Lbs.
Retrieved 2026-10-01
Dimensions · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
819 x 372 x 422 mm mm— 50 Hz · model
ISO 50 Hz; (L x W x H)
unspecified
Source · OEM_SOURCE
Dimensions (L x W x H): 819 x 372 x 422 mm
Retrieved 2026-10-01
819 x 372 x 422 mm mm— 60 Hz · model
ISO 60 Hz; (L x W x H)
unspecified
Source · OEM_SOURCE
different frequency
Dimensions (L x W x H): 819 x 372 x 422 mm
Retrieved 2026-10-01
32.2 x 14.6 x 16.6 inches inches— 60 Hz · model
US 60 Hz; (L x W x H)
unspecified
Source · OEM_SOURCE
different frequency
Dimensions (L x W x H): 32.2 x 14.6 x 16.6 inches
Retrieved 2026-10-01
Inlet connection · Sourced · 6 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
DN 100 ISO — 50 Hz · model
ISO 50 Hz; (horizontal)
unspecified
Source · OEM_SOURCE
Gas inlet (horizontal): DN 100 ISO
Retrieved 2026-10-01
DN 100 ISO — 50 Hz · model
ISO 50 Hz; (vertical)
unspecified
Source · OEM_SOURCE
Gas inlet (vertical): DN 100 ISO
Retrieved 2026-10-01
DN 100 ISO — 60 Hz · model
ISO 60 Hz; (horizontal)
unspecified
Source · OEM_SOURCE
different frequency
Gas inlet (horizontal): DN 100 ISO
Retrieved 2026-10-01
DN 100 ISO — 60 Hz · model
ISO 60 Hz; (vertical)
unspecified
Source · OEM_SOURCE
different frequency
Gas inlet (vertical): DN 100 ISO
Retrieved 2026-10-01
DN 100 ISO — 60 Hz · model
US 60 Hz; (horizontal)
unspecified
Source · OEM_SOURCE
different frequency
Gas inlet (horizontal): DN 100 ISO
Retrieved 2026-10-01
DN 100 ISO — 60 Hz · model
US 60 Hz; (vertical)
unspecified
Source · OEM_SOURCE
different frequency
Gas inlet (vertical): DN 100 ISO
Retrieved 2026-10-01
Outlet connection · Sourced · 6 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
DN 63 ISO — 50 Hz · model
ISO 50 Hz; (horizontal)
unspecified
Source · OEM_SOURCE
Gas outlet (horizontal): DN 63 ISO
Retrieved 2026-10-01
DN 100 ISO — 50 Hz · model
ISO 50 Hz; (vertical)
unspecified
Source · OEM_SOURCE
Gas outlet (vertical): DN 100 ISO
Retrieved 2026-10-01
DN 63 ISO — 60 Hz · model
ISO 60 Hz; (horizontal)
unspecified
Source · OEM_SOURCE
different frequency
Gas outlet (horizontal): DN 63 ISO
Retrieved 2026-10-01
DN 100 ISO — 60 Hz · model
ISO 60 Hz; (vertical)
unspecified
Source · OEM_SOURCE
different frequency
Gas outlet (vertical): DN 100 ISO
Retrieved 2026-10-01
DN 63 ISO — 60 Hz · model
US 60 Hz; (horizontal)
unspecified
Source · OEM_SOURCE
different frequency
Gas outlet (horizontal): DN 63 ISO
Retrieved 2026-10-01
DN 100 ISO — 60 Hz · model
US 60 Hz; (vertical)
unspecified
Source · OEM_SOURCE
different frequency
Gas outlet (vertical): DN 100 ISO
Retrieved 2026-10-01
Leakage Rate · Needs review · 3 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
≤ 1 · 10⁻⁶ mbar · l/s · 10⁻⁶ mbar · l/s— 50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_VERIFIED
Leakage rate: ≤ 1 · 10⁻⁶ mbar · l/s
Retrieved 2026-10-01
≤ 1 · 10⁻⁶ mbar · l/s · 10⁻⁶ mbar · l/s— 60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_VERIFIED
different frequency
Leakage rate: ≤ 1 · 10⁻⁶ mbar · l/s
Retrieved 2026-10-01
≤ 0.75 · 10⁻⁷ mbar · l/s · 10⁻⁷ mbar · l/s— 60 Hz · model
US 60 Hz
unspecified
Source · OEM_VERIFIED
different frequency
Leakage rate: ≤ 0.75 · 10⁻⁷ mbar · l/s
Retrieved 2026-10-01
Max. vacuum · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
100 hPa (mbar) hPa (mbar)100 mbar50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_VERIFIED
Max. differential pressure: 100 hPa (mbar)
Retrieved 2026-10-01
100 hPa (mbar) hPa (mbar)100 mbar60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_VERIFIED
different frequency
Max. differential pressure: 100 hPa (mbar)
Retrieved 2026-10-01
75 TORR TORR99.9915 mbar60 Hz · model
US 60 Hz
unspecified
Source · OEM_VERIFIED
different frequency
Max. differential pressure: 75 TORR
Retrieved 2026-10-01

Operating-performance coverage

Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.

No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.

Document coverage

Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.

CategoryModel linksFamily linksPublic sources
Specifications20
Performance curves / test data00Not collected
Operation / service manuals20
Parts documentation00Not collected
Drawings / dimensions00Not collected
Product / family literature00Not collected
Other / unclassified00Not collected