Data coverage & sources
The stored record for Busch PANDA WZ 0500 B: specifications, configurations, documents, sources, and gaps.
One model, connected records
Busch → PANDA WZ 0250–2400 A/B → PANDA WZ 0500 B
Manufacturer model: PANDA WZ 0500 B · OEM article / order number: Not collected · Equipment type: booster
Technology: Roots / Booster
Related applications: Leak Testing, Process Vacuum
Related industries: Automotive, Chemical, Metalworking, Oil + Gas, Power Generation, Semiconductor
These are technology associations. Check the operating point and process requirements to establish suitability for this model.
Compare coverage across this familySpecifications and evidence
36 stored observations · 11 pass the source policy at 50 Hz. Individual ratings do not establish flow at a requested pressure.
The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.
Pumping speed · Conflicting values · 6 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 525 m³/h m³/h | 525 m3/h | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_SOURCENominal pumping speed: 525 m³/hRetrieved 2026-10-01 |
| 464 m³/h m³/h | 464 m3/h | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_SOURCEPumping speed: 464 m³/hRetrieved 2026-10-01 |
| 630 m³/h m³/h | 630 m3/h | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_VERIFIED different frequency Nominal pumping speed: 630 m³/hRetrieved 2026-10-01 |
| 560 m³/h m³/h | 560 m3/h | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_VERIFIED different frequency Pumping speed: 560 m³/hRetrieved 2026-10-01 |
| 370.8 ACFM ACFM | 629.9929 m3/h | 60 Hz · model US 60 Hz actual inlet | Source · OEM_VERIFIED different frequency Nominal pumping speed: 370.8 ACFMRetrieved 2026-10-01 |
| 329.6 ACFM ACFM | 559.9937 m3/h | 60 Hz · model US 60 Hz actual inlet | Source · OEM_VERIFIED different frequency Pumping speed: 329.6 ACFMRetrieved 2026-10-01 |
Ultimate pressure · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Motor power · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 4.0 kW kW | 4 kW | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_SOURCENominal motor rating: 4.0 kWRetrieved 2026-10-01 |
| 4.4 kW kW | 4.4 kW | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_VERIFIED different frequency Nominal motor rating: 4.4 kWRetrieved 2026-10-01 |
| 5.9 hp hp | 4.3996 kW | 60 Hz · model US 60 Hz unspecified | Source · OEM_VERIFIED different frequency Nominal motor rating: 5.9 hpRetrieved 2026-10-01 |
Speed · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 3000 min⁻¹ min⁻¹ | 3000 rpm | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_SOURCENominal motor speed: 3000 min⁻¹Retrieved 2026-10-01 |
| 3600 min⁻¹ min⁻¹ | 3600 rpm | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_VERIFIED different frequency Nominal motor speed: 3600 min⁻¹Retrieved 2026-10-01 |
| 3600 RPM RPM | 3600 rpm | 60 Hz · model US 60 Hz unspecified | Source · OEM_VERIFIED different frequency Nominal motor speed: 3600 RPMRetrieved 2026-10-01 |
Noise level · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Weight · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 175 kg kg | 175 kg | 50 Hz · model ISO 50 Hz; approx. unspecified | Source · OEM_VERIFIEDWeight approx.: 175 kgRetrieved 2026-10-01 |
| 175 kg kg | 175 kg | 60 Hz · model ISO 60 Hz; approx. unspecified | Source · OEM_VERIFIED different frequency Weight approx.: 175 kgRetrieved 2026-10-01 |
| 385 Lbs. Lbs. | 174.6329 kg | 60 Hz · model US 60 Hz; approx. unspecified | Source · OEM_VERIFIED different frequency Weight approx.: 385 Lbs.Retrieved 2026-10-01 |
Dimensions · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 819 x 372 x 422 mm mm | — | 50 Hz · model ISO 50 Hz; (L x W x H) unspecified | Source · OEM_SOURCEDimensions (L x W x H): 819 x 372 x 422 mmRetrieved 2026-10-01 |
| 819 x 372 x 422 mm mm | — | 60 Hz · model ISO 60 Hz; (L x W x H) unspecified | Source · OEM_SOURCE different frequency Dimensions (L x W x H): 819 x 372 x 422 mmRetrieved 2026-10-01 |
| 32.2 x 14.6 x 16.6 inches inches | — | 60 Hz · model US 60 Hz; (L x W x H) unspecified | Source · OEM_SOURCE different frequency Dimensions (L x W x H): 32.2 x 14.6 x 16.6 inchesRetrieved 2026-10-01 |
Inlet connection · Sourced · 6 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| DN 100 ISO | — | 50 Hz · model ISO 50 Hz; (horizontal) unspecified | Source · OEM_SOURCEGas inlet (horizontal): DN 100 ISORetrieved 2026-10-01 |
| DN 100 ISO | — | 50 Hz · model ISO 50 Hz; (vertical) unspecified | Source · OEM_SOURCEGas inlet (vertical): DN 100 ISORetrieved 2026-10-01 |
| DN 100 ISO | — | 60 Hz · model ISO 60 Hz; (horizontal) unspecified | Source · OEM_SOURCE different frequency Gas inlet (horizontal): DN 100 ISORetrieved 2026-10-01 |
| DN 100 ISO | — | 60 Hz · model ISO 60 Hz; (vertical) unspecified | Source · OEM_SOURCE different frequency Gas inlet (vertical): DN 100 ISORetrieved 2026-10-01 |
| DN 100 ISO | — | 60 Hz · model US 60 Hz; (horizontal) unspecified | Source · OEM_SOURCE different frequency Gas inlet (horizontal): DN 100 ISORetrieved 2026-10-01 |
| DN 100 ISO | — | 60 Hz · model US 60 Hz; (vertical) unspecified | Source · OEM_SOURCE different frequency Gas inlet (vertical): DN 100 ISORetrieved 2026-10-01 |
Outlet connection · Sourced · 6 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| DN 63 ISO | — | 50 Hz · model ISO 50 Hz; (horizontal) unspecified | Source · OEM_SOURCEGas outlet (horizontal): DN 63 ISORetrieved 2026-10-01 |
| DN 100 ISO | — | 50 Hz · model ISO 50 Hz; (vertical) unspecified | Source · OEM_SOURCEGas outlet (vertical): DN 100 ISORetrieved 2026-10-01 |
| DN 63 ISO | — | 60 Hz · model ISO 60 Hz; (horizontal) unspecified | Source · OEM_SOURCE different frequency Gas outlet (horizontal): DN 63 ISORetrieved 2026-10-01 |
| DN 100 ISO | — | 60 Hz · model ISO 60 Hz; (vertical) unspecified | Source · OEM_SOURCE different frequency Gas outlet (vertical): DN 100 ISORetrieved 2026-10-01 |
| DN 63 ISO | — | 60 Hz · model US 60 Hz; (horizontal) unspecified | Source · OEM_SOURCE different frequency Gas outlet (horizontal): DN 63 ISORetrieved 2026-10-01 |
| DN 100 ISO | — | 60 Hz · model US 60 Hz; (vertical) unspecified | Source · OEM_SOURCE different frequency Gas outlet (vertical): DN 100 ISORetrieved 2026-10-01 |
Leakage Rate · Needs review · 3 observations / 1 sources · classification pending
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| ≤ 1 · 10⁻⁶ mbar · l/s · 10⁻⁶ mbar · l/s | — | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_VERIFIEDLeakage rate: ≤ 1 · 10⁻⁶ mbar · l/sRetrieved 2026-10-01 |
| ≤ 1 · 10⁻⁶ mbar · l/s · 10⁻⁶ mbar · l/s | — | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_VERIFIED different frequency Leakage rate: ≤ 1 · 10⁻⁶ mbar · l/sRetrieved 2026-10-01 |
| ≤ 0.75 · 10⁻⁷ mbar · l/s · 10⁻⁷ mbar · l/s | — | 60 Hz · model US 60 Hz unspecified | Source · OEM_VERIFIED different frequency Leakage rate: ≤ 0.75 · 10⁻⁷ mbar · l/sRetrieved 2026-10-01 |
Max. vacuum · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 100 hPa (mbar) hPa (mbar) | 100 mbar | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_VERIFIEDMax. differential pressure: 100 hPa (mbar)Retrieved 2026-10-01 |
| 100 hPa (mbar) hPa (mbar) | 100 mbar | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_VERIFIED different frequency Max. differential pressure: 100 hPa (mbar)Retrieved 2026-10-01 |
| 75 TORR TORR | 99.9915 mbar | 60 Hz · model US 60 Hz unspecified | Source · OEM_VERIFIED different frequency Max. differential pressure: 75 TORRRetrieved 2026-10-01 |
Operating-performance coverage
Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.
No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.
Document coverage
Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.
| Category | Model links | Family links | Public sources |
|---|---|---|---|
| Specifications | 2 | 0 |
|
| Performance curves / test data | 0 | 0 | Not collected |
| Operation / service manuals | 2 | 0 |
|
| Parts documentation | 0 | 0 | Not collected |
| Drawings / dimensions | 0 | 0 | Not collected |
| Product / family literature | 0 | 0 | Not collected |
| Other / unclassified | 0 | 0 | Not collected |