Find equipmentComparePartsManufacturersTechnologiesIndustriesApplicationsAsset trackingMy equipmentTalk to a specialist

Data coverage & sources

The stored record for Busch PUMA WP 0500 D2: specifications, configurations, documents, sources, and gaps.

One model, connected records

Busch → PUMA WP 0500 D2 → PUMA WP 0500 D2

Manufacturer model: PUMA WP 0500 D2 · OEM article / order number: Not collected · Equipment type: booster

Technology: Roots / Booster

Related applications: Leak Testing, Process Vacuum
Related industries: Automotive, Chemical, Metalworking, Oil + Gas, Power Generation, Semiconductor

These are technology associations. Check the operating point and process requirements to establish suitability for this model.

Compare coverage across this family

Specifications and evidence

27 stored observations · 9 pass the source policy at 50 Hz. Individual ratings do not establish flow at a requested pressure.

The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.

Pumping speed · Conflicting values · 6 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
520 m³/h m³/h520 m3/h50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
Nominal pumping speed: 520 m³/h
Retrieved 2026-10-01
463 m³/h m³/h463 m3/h50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
Pumping speed: 463 m³/h
Retrieved 2026-10-01
620 m³/h m³/h620 m3/h60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_VERIFIED
different frequency
Nominal pumping speed: 620 m³/h
Retrieved 2026-10-01
554 m³/h m³/h554 m3/h60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_VERIFIED
different frequency
Pumping speed: 554 m³/h
Retrieved 2026-10-01
310 ACFM ACFM526.6931 m3/h60 Hz · model
US 60 Hz
actual inlet
Source · OEM_VERIFIED
different frequency
Nominal pumping speed: 310 ACFM
Retrieved 2026-10-01
308 ACFM ACFM523.2951 m3/h60 Hz · model
US 60 Hz
actual inlet
Source · OEM_VERIFIED
different frequency
Pumping speed: 308 ACFM
Retrieved 2026-10-01
Ultimate pressure · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Motor power · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
2.2 kW kW2.2 kW50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
Nominal motor rating: 2.2 kW
Retrieved 2026-10-01
3.0 kW kW3 kW60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_VERIFIED
different frequency
Nominal motor rating: 3.0 kW
Retrieved 2026-10-01
4 hp hp2.9828 kW60 Hz · model
US 60 Hz
unspecified
Source · OEM_VERIFIED
different frequency
Nominal motor rating: 4 hp
Retrieved 2026-10-01
Speed · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
3000 min⁻¹ min⁻¹3000 rpm50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
Nominal motor speed: 3000 min⁻¹
Retrieved 2026-10-01
3600 min⁻¹ min⁻¹3600 rpm60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_VERIFIED
different frequency
Nominal motor speed: 3600 min⁻¹
Retrieved 2026-10-01
3600 RPM RPM3600 rpm60 Hz · model
US 60 Hz
unspecified
Source · OEM_VERIFIED
different frequency
Nominal motor speed: 3600 RPM
Retrieved 2026-10-01
Noise level · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Weight · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
150 kg kg150 kg50 Hz · model
ISO 50 Hz; approx.
unspecified
Source · OEM_VERIFIED
Weight approx.: 150 kg
Retrieved 2026-10-01
150 kg kg150 kg60 Hz · model
ISO 60 Hz; approx.
unspecified
Source · OEM_VERIFIED
different frequency
Weight approx.: 150 kg
Retrieved 2026-10-01
390 Lbs. Lbs.176.9009 kg60 Hz · model
US 60 Hz; approx.
unspecified
Source · OEM_VERIFIED
different frequency
Weight approx.: 390 Lbs.
Retrieved 2026-10-01
Dimensions · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
813 x 345 x 494 — 50 Hz · model
ISO 50 Hz; (L x W x H)
unspecified
Source · OEM_SOURCE
Dimensions (L x W x H): 813 x 345 x 494
Retrieved 2026-10-01
813 x 345 x 494 — 60 Hz · model
ISO 60 Hz; (L x W x H)
unspecified
Source · OEM_SOURCE
different frequency
Dimensions (L x W x H): 813 x 345 x 494
Retrieved 2026-10-01
32.5 x 12.4 x 19.5 — 60 Hz · model
US 60 Hz; (L x W x H)
unspecified
Source · OEM_SOURCE
different frequency
Dimensions (L x W x H): 32.5 x 12.4 x 19.5
Retrieved 2026-10-01
Inlet connection · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
DN 63 ISO — 50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
Gas inlet: DN 63 ISO
Retrieved 2026-10-01
DN 63 ISO — 60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_SOURCE
different frequency
Gas inlet: DN 63 ISO
Retrieved 2026-10-01
DN 63 ISO — 60 Hz · model
US 60 Hz
unspecified
Source · OEM_SOURCE
different frequency
Gas inlet: DN 63 ISO
Retrieved 2026-10-01
Outlet connection · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
DN 63 ISO — 50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
Gas outlet: DN 63 ISO
Retrieved 2026-10-01
DN 63 ISO — 60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_SOURCE
different frequency
Gas outlet: DN 63 ISO
Retrieved 2026-10-01
DN 63 ISO — 60 Hz · model
US 60 Hz
unspecified
Source · OEM_SOURCE
different frequency
Gas outlet: DN 63 ISO
Retrieved 2026-10-01
Max. vacuum · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
50 hPa (mbar) hPa (mbar)50 mbar50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_VERIFIED
Max. differential pressure: 50 hPa (mbar)
Retrieved 2026-10-01
50 hPa (mbar) hPa (mbar)50 mbar60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_VERIFIED
different frequency
Max. differential pressure: 50 hPa (mbar)
Retrieved 2026-10-01
40 TORR TORR53.3288 mbar60 Hz · model
US 60 Hz
unspecified
Source · OEM_VERIFIED
different frequency
Max. differential pressure: 40 TORR
Retrieved 2026-10-01

Operating-performance coverage

Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.

No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.

Document coverage

Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.

CategoryModel linksFamily linksPublic sources
Specifications30
Performance curves / test data00Not collected
Operation / service manuals00Not collected
Parts documentation00Not collected
Drawings / dimensions00Not collected
Product / family literature00Not collected
Other / unclassified00Not collected