Find equipmentComparePartsManufacturersTechnologiesIndustriesApplicationsAsset trackingMy equipmentTalk to a specialist

Data coverage & sources

The stored record for Busch PUMA WY 1250 C: specifications, configurations, documents, sources, and gaps.

One model, connected records

Busch → PUMA WY 0500–2000 C → PUMA WY 1250 C

Manufacturer model: PUMA WY 1250 C · OEM article / order number: Not collected · Equipment type: booster

Technology: Roots / Booster

Related applications: Leak Testing, Process Vacuum
Related industries: Automotive, Chemical, Metalworking, Oil + Gas, Power Generation, Semiconductor

These are technology associations. Check the operating point and process requirements to establish suitability for this model.

Compare coverage across this family

Specifications and evidence

30 stored observations · 18 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.

The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.

Pumping speed · Conflicting values · 6 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
1250 m³/h m³/h1250 m3/h50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
different frequency
Nominal pumping speed: 1250 m³/h
Retrieved 2026-10-01
1080 m³/h m³/h1080 m3/h50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
different frequency
Pumping speed: 1080 m³/h
Retrieved 2026-10-01
1500 m³/h m³/h1500 m3/h60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_VERIFIED
Nominal pumping speed: 1500 m³/h
Retrieved 2026-10-01
1290 m³/h m³/h1290 m3/h60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_VERIFIED
Pumping speed: 1290 m³/h
Retrieved 2026-10-01
885 ACFM ACFM1503.624 m3/h60 Hz · model
US 60 Hz
actual inlet
Source · OEM_VERIFIED
Nominal pumping speed: 885 ACFM
Retrieved 2026-10-01
565 ACFM ACFM959.9407 m3/h60 Hz · model
US 60 Hz
actual inlet
Source · OEM_VERIFIED
Pumping speed: 565 ACFM
Retrieved 2026-10-01
Ultimate pressure · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Motor power · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
4.0 kW kW4 kW50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
different frequency
Nominal motor rating: 4.0 kW
Retrieved 2026-10-01
4.4 kW kW4.4 kW60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_VERIFIED
Nominal motor rating: 4.4 kW
Retrieved 2026-10-01
5.9 hp hp4.3996 kW60 Hz · model
US 60 Hz
unspecified
Source · OEM_VERIFIED
Nominal motor rating: 5.9 hp
Retrieved 2026-10-01
Speed · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
3000 min⁻¹ min⁻¹3000 rpm50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
different frequency
Nominal motor speed: 3000 min⁻¹
Retrieved 2026-10-01
3600 min⁻¹ min⁻¹3600 rpm60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_VERIFIED
Nominal motor speed: 3600 min⁻¹
Retrieved 2026-10-01
3600 RPM RPM3600 rpm60 Hz · model
US 60 Hz
unspecified
Source · OEM_VERIFIED
Nominal motor speed: 3600 RPM
Retrieved 2026-10-01
Noise level · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Weight · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
250 kg kg250 kg50 Hz · model
ISO 50 Hz; approx.
unspecified
Source · OEM_VERIFIED
different frequency
Weight approx.: 250 kg
Retrieved 2026-10-01
250 kg kg250 kg60 Hz · model
ISO 60 Hz; approx.
unspecified
Source · OEM_VERIFIED
Weight approx.: 250 kg
Retrieved 2026-10-01
551 Lbs. Lbs.249.9292 kg60 Hz · model
US 60 Hz; approx.
unspecified
Source · OEM_VERIFIED
Weight approx.: 551 Lbs.
Retrieved 2026-10-01
Dimensions · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
852 x 325 x 260 — 50 Hz · model
ISO 50 Hz; (L x W x H)
unspecified
Source · OEM_SOURCE
different frequency
Dimensions (L x W x H): 852 x 325 x 260
Retrieved 2026-10-01
852 x 325 x 260 — 60 Hz · model
ISO 60 Hz; (L x W x H)
unspecified
Source · OEM_SOURCE
Dimensions (L x W x H): 852 x 325 x 260
Retrieved 2026-10-01
36.1 x 13.6 x 10.6 — 60 Hz · model
US 60 Hz; (L x W x H)
unspecified
Source · OEM_SOURCE
Dimensions (L x W x H): 36.1 x 13.6 x 10.6
Retrieved 2026-10-01
Inlet connection · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
DN 160 ISO — 50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
different frequency
Gas inlet: DN 160 ISO
Retrieved 2026-10-01
DN 160 ISO — 60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_SOURCE
Gas inlet: DN 160 ISO
Retrieved 2026-10-01
DN 160 ISO-F — 60 Hz · model
US 60 Hz
unspecified
Source · OEM_SOURCE
Gas inlet: DN 160 ISO-F
Retrieved 2026-10-01
Outlet connection · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
DN 160 ISO — 50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_SOURCE
different frequency
Gas outlet: DN 160 ISO
Retrieved 2026-10-01
DN 160 ISO — 60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_SOURCE
Gas outlet: DN 160 ISO
Retrieved 2026-10-01
DN 160 ISO-F — 60 Hz · model
US 60 Hz
unspecified
Source · OEM_SOURCE
Gas outlet: DN 160 ISO-F
Retrieved 2026-10-01
Leakage Rate · Needs review · 3 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
< 1 · 10⁻⁶ mbar · l/s · 10⁻⁶ mbar · l/s— 50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_VERIFIED
different frequency
Leakage rate: < 1 · 10⁻⁶ mbar · l/s
Retrieved 2026-10-01
< 1 · 10⁻⁶ mbar · l/s · 10⁻⁶ mbar · l/s— 60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_VERIFIED
Leakage rate: < 1 · 10⁻⁶ mbar · l/s
Retrieved 2026-10-01
< 0.75 · 10⁻⁷ mbar · l/s · 10⁻⁷ mbar · l/s— 60 Hz · model
US 60 Hz
unspecified
Source · OEM_VERIFIED
Leakage rate: < 0.75 · 10⁻⁷ mbar · l/s
Retrieved 2026-10-01
Max. vacuum · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
50 hPa (mbar) hPa (mbar)50 mbar50 Hz · model
ISO 50 Hz
unspecified
Source · OEM_VERIFIED
different frequency
Max. differential pressure: 50 hPa (mbar)
Retrieved 2026-10-01
50 hPa (mbar) hPa (mbar)50 mbar60 Hz · model
ISO 60 Hz
unspecified
Source · OEM_VERIFIED
Max. differential pressure: 50 hPa (mbar)
Retrieved 2026-10-01
40 TORR TORR53.3288 mbar60 Hz · model
US 60 Hz
unspecified
Source · OEM_VERIFIED
Max. differential pressure: 40 TORR
Retrieved 2026-10-01

Operating-performance coverage

Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.

No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.

Document coverage

Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.

CategoryModel linksFamily linksPublic sources
Specifications50
Performance curves / test data00Not collected
Operation / service manuals10
Parts documentation00Not collected
Drawings / dimensions00Not collected
Product / family literature00Not collected
Other / unclassified00Not collected