Data coverage & sources
The stored record for Busch PUMA WY 1250 C: specifications, configurations, documents, sources, and gaps.
One model, connected records
Busch → PUMA WY 0500–2000 C → PUMA WY 1250 C
Manufacturer model: PUMA WY 1250 C · OEM article / order number: Not collected · Equipment type: booster
Technology: Roots / Booster
Related applications: Leak Testing, Process Vacuum
Related industries: Automotive, Chemical, Metalworking, Oil + Gas, Power Generation, Semiconductor
These are technology associations. Check the operating point and process requirements to establish suitability for this model.
Compare coverage across this familySpecifications and evidence
30 stored observations · 9 pass the source policy at 50 Hz. Individual ratings do not establish flow at a requested pressure.
The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.
Pumping speed · Conflicting values · 6 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 1250 m³/h m³/h | 1250 m3/h | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_SOURCENominal pumping speed: 1250 m³/hRetrieved 2026-10-01 |
| 1080 m³/h m³/h | 1080 m3/h | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_SOURCEPumping speed: 1080 m³/hRetrieved 2026-10-01 |
| 1500 m³/h m³/h | 1500 m3/h | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_VERIFIED different frequency Nominal pumping speed: 1500 m³/hRetrieved 2026-10-01 |
| 1290 m³/h m³/h | 1290 m3/h | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_VERIFIED different frequency Pumping speed: 1290 m³/hRetrieved 2026-10-01 |
| 885 ACFM ACFM | 1503.624 m3/h | 60 Hz · model US 60 Hz actual inlet | Source · OEM_VERIFIED different frequency Nominal pumping speed: 885 ACFMRetrieved 2026-10-01 |
| 565 ACFM ACFM | 959.9407 m3/h | 60 Hz · model US 60 Hz actual inlet | Source · OEM_VERIFIED different frequency Pumping speed: 565 ACFMRetrieved 2026-10-01 |
Ultimate pressure · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Motor power · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 4.0 kW kW | 4 kW | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_SOURCENominal motor rating: 4.0 kWRetrieved 2026-10-01 |
| 4.4 kW kW | 4.4 kW | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_VERIFIED different frequency Nominal motor rating: 4.4 kWRetrieved 2026-10-01 |
| 5.9 hp hp | 4.3996 kW | 60 Hz · model US 60 Hz unspecified | Source · OEM_VERIFIED different frequency Nominal motor rating: 5.9 hpRetrieved 2026-10-01 |
Speed · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 3000 min⁻¹ min⁻¹ | 3000 rpm | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_SOURCENominal motor speed: 3000 min⁻¹Retrieved 2026-10-01 |
| 3600 min⁻¹ min⁻¹ | 3600 rpm | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_VERIFIED different frequency Nominal motor speed: 3600 min⁻¹Retrieved 2026-10-01 |
| 3600 RPM RPM | 3600 rpm | 60 Hz · model US 60 Hz unspecified | Source · OEM_VERIFIED different frequency Nominal motor speed: 3600 RPMRetrieved 2026-10-01 |
Noise level · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Weight · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 250 kg kg | 250 kg | 50 Hz · model ISO 50 Hz; approx. unspecified | Source · OEM_VERIFIEDWeight approx.: 250 kgRetrieved 2026-10-01 |
| 250 kg kg | 250 kg | 60 Hz · model ISO 60 Hz; approx. unspecified | Source · OEM_VERIFIED different frequency Weight approx.: 250 kgRetrieved 2026-10-01 |
| 551 Lbs. Lbs. | 249.9292 kg | 60 Hz · model US 60 Hz; approx. unspecified | Source · OEM_VERIFIED different frequency Weight approx.: 551 Lbs.Retrieved 2026-10-01 |
Dimensions · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 852 x 325 x 260 | — | 50 Hz · model ISO 50 Hz; (L x W x H) unspecified | Source · OEM_SOURCEDimensions (L x W x H): 852 x 325 x 260Retrieved 2026-10-01 |
| 852 x 325 x 260 | — | 60 Hz · model ISO 60 Hz; (L x W x H) unspecified | Source · OEM_SOURCE different frequency Dimensions (L x W x H): 852 x 325 x 260Retrieved 2026-10-01 |
| 36.1 x 13.6 x 10.6 | — | 60 Hz · model US 60 Hz; (L x W x H) unspecified | Source · OEM_SOURCE different frequency Dimensions (L x W x H): 36.1 x 13.6 x 10.6Retrieved 2026-10-01 |
Inlet connection · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| DN 160 ISO | — | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_SOURCEGas inlet: DN 160 ISORetrieved 2026-10-01 |
| DN 160 ISO | — | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_SOURCE different frequency Gas inlet: DN 160 ISORetrieved 2026-10-01 |
| DN 160 ISO-F | — | 60 Hz · model US 60 Hz unspecified | Source · OEM_SOURCE different frequency Gas inlet: DN 160 ISO-FRetrieved 2026-10-01 |
Outlet connection · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| DN 160 ISO | — | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_SOURCEGas outlet: DN 160 ISORetrieved 2026-10-01 |
| DN 160 ISO | — | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_SOURCE different frequency Gas outlet: DN 160 ISORetrieved 2026-10-01 |
| DN 160 ISO-F | — | 60 Hz · model US 60 Hz unspecified | Source · OEM_SOURCE different frequency Gas outlet: DN 160 ISO-FRetrieved 2026-10-01 |
Leakage Rate · Needs review · 3 observations / 1 sources · classification pending
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| < 1 · 10⁻⁶ mbar · l/s · 10⁻⁶ mbar · l/s | — | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_VERIFIEDLeakage rate: < 1 · 10⁻⁶ mbar · l/sRetrieved 2026-10-01 |
| < 1 · 10⁻⁶ mbar · l/s · 10⁻⁶ mbar · l/s | — | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_VERIFIED different frequency Leakage rate: < 1 · 10⁻⁶ mbar · l/sRetrieved 2026-10-01 |
| < 0.75 · 10⁻⁷ mbar · l/s · 10⁻⁷ mbar · l/s | — | 60 Hz · model US 60 Hz unspecified | Source · OEM_VERIFIED different frequency Leakage rate: < 0.75 · 10⁻⁷ mbar · l/sRetrieved 2026-10-01 |
Max. vacuum · Sourced · 3 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 50 hPa (mbar) hPa (mbar) | 50 mbar | 50 Hz · model ISO 50 Hz unspecified | Source · OEM_VERIFIEDMax. differential pressure: 50 hPa (mbar)Retrieved 2026-10-01 |
| 50 hPa (mbar) hPa (mbar) | 50 mbar | 60 Hz · model ISO 60 Hz unspecified | Source · OEM_VERIFIED different frequency Max. differential pressure: 50 hPa (mbar)Retrieved 2026-10-01 |
| 40 TORR TORR | 53.3288 mbar | 60 Hz · model US 60 Hz unspecified | Source · OEM_VERIFIED different frequency Max. differential pressure: 40 TORRRetrieved 2026-10-01 |
Operating-performance coverage
Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.
No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.
Document coverage
Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.
| Category | Model links | Family links | Public sources |
|---|---|---|---|
| Specifications | 5 | 0 |
|
| Performance curves / test data | 0 | 0 | Not collected |
| Operation / service manuals | 1 | 0 |
|
| Parts documentation | 0 | 0 | Not collected |
| Drawings / dimensions | 0 | 0 | Not collected |
| Product / family literature | 0 | 0 | Not collected |
| Other / unclassified | 0 | 0 | Not collected |