One model, connected records

CompAir → CompAir DX90–DX160 oil-free screw compressors technical data → DX90

Manufacturer model: DX90 · OEM article / order number: Not collected · Equipment type: compressor

Technology: Oil-Free Screw / Rotary Screw

Related applications: Food-Contact Air, Instrument Air, Medical Air, Plant Air, Pressure Conveying, Spray + Finishing
Related industries: Automotive, Chemical, Electronics, Food + Beverage, General Manufacturing, Metalworking, Mining, Oil + Gas, Packaging, Pharmaceutical, Plastics, Power Generation, Printing, Pulp + Paper, Semiconductor, Water + Wastewater, Woodworking + CNC

These are technology associations. Check the operating point and process requirements to establish suitability for this model.

Compare coverage across this family

Specifications and evidence

14 stored observations · 14 pass the source policy at 50 Hz. Individual ratings do not establish flow at a requested pressure.

The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.

Free air delivery · Sourced · 6 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
17.4 m³/min1044 m3/hFrequency not stated · model
air-cooled, at 7 bar g
free air delivery
Source · OEM_SOURCE
Free air delivered: 17.4
Retrieved 2026-10-04
16.7 m³/min1002 m3/hFrequency not stated · model
air-cooled, at 8 bar g
free air delivery
Source · OEM_SOURCE
Free air delivered: 16.7
Retrieved 2026-10-04
14.6 m³/min876 m3/hFrequency not stated · model
air-cooled, at 10 bar g
free air delivery
Source · OEM_SOURCE
Free air delivered: 14.6
Retrieved 2026-10-04
17.6 m³/min1056 m3/hFrequency not stated · model
water-cooled, at 7 bar g
free air delivery
Source · OEM_SOURCE
Free air delivered: 17.6
Retrieved 2026-10-04
16.7 m³/min1002 m3/hFrequency not stated · model
water-cooled, at 8 bar g
free air delivery
Source · OEM_SOURCE
Free air delivered: 16.7
Retrieved 2026-10-04
14.9 m³/min894 m3/hFrequency not stated · model
water-cooled, at 10 bar g
free air delivery
Source · OEM_SOURCE
Free air delivered: 14.9
Retrieved 2026-10-04
Max. pressure · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Motor power · Sourced · 1 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
90 kW90 kWFrequency not stated · model
Conditions not stated
unspecified
Source · OEM_SOURCE
Motor rating: 90
Retrieved 2026-10-04
Speed · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Noise level · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
78 dB(A)78 dB(A)Frequency not stated · model
air-cooled
unspecified
Source · OEM_SOURCE
Noise level: 78
Retrieved 2026-10-04
75 dB(A)75 dB(A)Frequency not stated · model
water-cooled
unspecified
Source · OEM_SOURCE
Noise level: 75
Retrieved 2026-10-04
Weight · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
3441 kg3441 kgFrequency not stated · model
air-cooled
unspecified
Source · OEM_SOURCE
Weight: 3441
Retrieved 2026-10-04
3309 kg3309 kgFrequency not stated · model
water-cooled
unspecified
Source · OEM_SOURCE
Weight: 3309
Retrieved 2026-10-04
Dimensions · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Inlet connection · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Outlet connection · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Reference working pressure · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
10 barg10000 mbarFrequency not stated · model
the pressure "Free air delivered" is stated at (air-cooled, at 10 bar g)
unspecified
Source · OEM_SOURCE
Free air delivered: 14.6
Retrieved 2026-10-20
7 barg7000 mbarFrequency not stated · model
the pressure "Free air delivered" is stated at (air-cooled, at 7 bar g)
unspecified
Source · OEM_SOURCE
Free air delivered: 17.4
Retrieved 2026-10-20
8 barg8000 mbarFrequency not stated · model
the pressure "Free air delivered" is stated at (air-cooled, at 8 bar g)
unspecified
Source · OEM_SOURCE
Free air delivered: 16.7
Retrieved 2026-10-20

Operating-performance coverage

Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.

No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.

Document coverage

Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.

CategoryModel linksFamily linksPublic sources
Specifications10
Performance curves / test data00Not collected
Operation / service manuals00Not collected
Parts documentation00Not collected
Drawings / dimensions00Not collected
Product / family literature10