The stored record for DENAIR DVAH-200: specifications, configurations, documents, sources, and gaps.
One model, connected records
DENAIR → DENAIR High Pressure Screw Air Compressor → DVAH-200
Manufacturer model: DVAH-200 · OEM article / order number: Not collected · Equipment type: compressor
Technology: Rotary Screw
Related applications: Plant Air, Pressure Conveying, Spray + Finishing
Related industries: Automotive, Chemical, General Manufacturing, Metalworking, Mining, Oil + Gas, Packaging, Plastics, Power Generation, Printing, Pulp + Paper, Water + Wastewater, Woodworking + CNC
These are technology associations. Check the operating point and process requirements to establish suitability for this model.
Compare coverage across this familySpecifications and evidence
21 stored observations · 15 pass the source policy at 50 Hz. Individual ratings do not establish flow at a requested pressure.
The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.
Free air delivery · Sourced · 12 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 24.14 m³/min | 1448.4 m3/h | 50 Hz · model 50 Hz, at 14 bar(g); (FAD), max. free air delivery | Source · OEM_SOURCECapacity (FAD), max.: 24.14Retrieved 2026-10-06 |
| 23.09 m³/min | 1385.4 m3/h | 60 Hz · model 60 Hz, at 14 bar(g); (FAD), max. free air delivery | Source · OEM_SOURCE different frequency Capacity (FAD), max.: 23.09Retrieved 2026-10-06 |
| 21.36 m³/min | 1281.6 m3/h | 50 Hz · model 50 Hz, at 15 bar(g); (FAD), max. free air delivery | Source · OEM_SOURCECapacity (FAD), max.: 21.36Retrieved 2026-10-06 |
| 23.02 m³/min | 1381.2 m3/h | 60 Hz · model 60 Hz, at 15 bar(g); (FAD), max. free air delivery | Source · OEM_SOURCE different frequency Capacity (FAD), max.: 23.02Retrieved 2026-10-06 |
| 21.24 m³/min | 1274.4 m3/h | 50 Hz · model 50 Hz, at 16 bar(g); (FAD), max. free air delivery | Source · OEM_SOURCECapacity (FAD), max.: 21.24Retrieved 2026-10-06 |
| 22.98 m³/min | 1378.8 m3/h | 60 Hz · model 60 Hz, at 16 bar(g); (FAD), max. free air delivery | Source · OEM_SOURCE different frequency Capacity (FAD), max.: 22.98Retrieved 2026-10-06 |
| 26.04 m³/min | 1562.4 m3/h | 50 Hz · model 50 Hz, at 18 bar(g); (FAD), max. free air delivery | Source · OEM_SOURCECapacity (FAD), max.: 26.04Retrieved 2026-10-06 |
| 24.51 m³/min | 1470.6 m3/h | 60 Hz · model 60 Hz, at 18 bar(g); (FAD), max. free air delivery | Source · OEM_SOURCE different frequency Capacity (FAD), max.: 24.51Retrieved 2026-10-06 |
| 23.73 m³/min | 1423.8 m3/h | 50 Hz · model 50 Hz, at 20 bar(g); (FAD), max. free air delivery | Source · OEM_SOURCECapacity (FAD), max.: 23.73Retrieved 2026-10-06 |
| 22.16 m³/min | 1329.6 m3/h | 60 Hz · model 60 Hz, at 20 bar(g); (FAD), max. free air delivery | Source · OEM_SOURCE different frequency Capacity (FAD), max.: 22.16Retrieved 2026-10-06 |
| 21.62 m³/min | 1297.2 m3/h | 50 Hz · model 50 Hz, at 25 bar(g); (FAD), max. free air delivery | Source · OEM_SOURCECapacity (FAD), max.: 21.62Retrieved 2026-10-06 |
| 21.95 m³/min | 1317 m3/h | 60 Hz · model 60 Hz, at 25 bar(g); (FAD), max. free air delivery | Source · OEM_SOURCE different frequency Capacity (FAD), max.: 21.95Retrieved 2026-10-06 |
Max. pressure · Sourced · 6 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 14 bar | 14000 mbar | Frequency not stated · model at 14 bar(g) unspecified | Source · OEM_SOURCEMaximum working pressure: 14Retrieved 2026-10-06 |
| 15 bar | 15000 mbar | Frequency not stated · model at 15 bar(g) unspecified | Source · OEM_SOURCEMaximum working pressure: 15Retrieved 2026-10-06 |
| 16 bar | 16000 mbar | Frequency not stated · model at 16 bar(g) unspecified | Source · OEM_SOURCEMaximum working pressure: 16Retrieved 2026-10-06 |
| 18 bar | 18000 mbar | Frequency not stated · model at 18 bar(g) unspecified | Source · OEM_SOURCEMaximum working pressure: 18Retrieved 2026-10-06 |
| 20 bar | 20000 mbar | Frequency not stated · model at 20 bar(g) unspecified | Source · OEM_SOURCEMaximum working pressure: 20Retrieved 2026-10-06 |
| 25 bar | 25000 mbar | Frequency not stated · model at 25 bar(g) unspecified | Source · OEM_SOURCEMaximum working pressure: 25Retrieved 2026-10-06 |
Motor power · Sourced · 1 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 200 kW | 200 kW | Frequency not stated · model Conditions not stated unspecified | Source · OEM_SOURCEInstalled motor power: 200Retrieved 2026-10-06 |
Speed · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Noise level · Sourced · 1 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 85 dB(A) | 85 dB(A) | Frequency not stated · model Conditions not stated unspecified | Source · OEM_SOURCENoise level: 85Retrieved 2026-10-06 |
Weight · Sourced · 1 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 6000 kg | 6000 kg | Frequency not stated · model Conditions not stated unspecified | Source · OEM_SOURCEWeight: 6000Retrieved 2026-10-06 |
Dimensions · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Inlet connection · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Outlet connection · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Operating-performance coverage
Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.
No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.
Document coverage
Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.
| Category | Model links | Family links | Public sources |
|---|---|---|---|
| Specifications | 0 | 0 | Not collected |
| Performance curves / test data | 0 | 0 | Not collected |
| Operation / service manuals | 0 | 0 | Not collected |
| Parts documentation | 0 | 0 | Not collected |
| Drawings / dimensions | 0 | 0 | Not collected |
| Product / family literature | 2 | 0 |
|
| Other / unclassified | 1 | 0 |
|