Find equipmentComparePartsManufacturersTechnologiesIndustriesApplicationsAsset trackingMy equipmentTalk to a specialist

Data coverage & sources

The stored record for Edwards EXS160: specifications, configurations, documents, sources, and gaps.

One model, connected records

Edwards → EXS Dry Screw Vacuum Pumps → EXS160

Manufacturer model: EXS160 · OEM article / order number: Not collected · Equipment type: vacuum pump

Technology: Dry Screw

Related applications: Degassing, Drying, Process Vacuum
Related industries: Chemical, Oil + Gas, Pharmaceutical, Semiconductor

These are technology associations. Check the operating point and process requirements to establish suitability for this model.

Compare coverage across this family

Specifications and evidence

22 stored observations · 5 pass the source policy at 50 Hz. Individual ratings do not establish flow at a requested pressure.

The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.

Pumping speed · Sourced · 1 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
160 m3/hr160 m3/hFrequency not stated · model
Conditions not stated
unspecified
Source · OEM_SOURCE
Peak pumping speed: 160
Retrieved 2026-10-02
Ultimate pressure · Needs review · 1 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
1x10 -2 mbar0.01 mbarFrequency not stated · range
Conditions not stated
unspecified
Source · OEM_SOURCE
not a model rating
Ultimate vacuum: 1x10 -2
Retrieved 2026-10-02
Motor power · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Speed · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Noise level · Sourced · 1 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
<64 dB(A)64 dB(A)Frequency not stated · model
with silencer
unspecified
Source · OEM_SOURCE
Noise level with silencer: <64
Retrieved 2026-10-02
Weight · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Dimensions · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Inlet connection · Sourced · 1 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
ISO63/NW40 — Frequency not stated · model
/Outlet
unspecified
Source · OEM_SOURCE
Inlet/Outlet: ISO63/NW40
Retrieved 2026-10-02
Outlet connection · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Ambient temperature · Needs review · 1 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
5-40 °C5 °CFrequency not stated · range
range
unspecified
Source · OEM_SOURCE
not a model rating
Ambient temperature range: 5-40
Retrieved 2026-10-02
Connection · Needs review · 2 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
⅜" BSP male inch— Frequency not stated · model
Conditions not stated
unspecified
Source · OEM_SOURCE
Connection: ⅜" BSP male
Retrieved 2026-10-02
½" BSP male inch— Frequency not stated · model
Conditions not stated
unspecified
Source · OEM_SOURCE
Connection: ½" BSP male
Retrieved 2026-10-02
Cooling Flow Always On · Needs review · 1 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
4.0 l/min0.24 m3/hFrequency not stated · model
Conditions not stated
unspecified
Source · OEM_SOURCE
Cooling flow (Always on): 4.0
Retrieved 2026-10-02
Electrical Supply · Needs review · 1 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
380-460V 3Ph 50/60Hz 200-230V 3Ph 50/60Hz V 3Ph 50/60Hz 200-230V 3Ph 50/60Hz V— Frequency not stated · range
Conditions not stated
unspecified
Source · OEM_SOURCE
not a model rating
Electrical supply: 380-460V 3Ph 50/60Hz 200-230V 3Ph 50/60Hz
Retrieved 2026-10-02
Full Load Power · Needs review · 1 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
5.0 kW5 kWFrequency not stated · model
Conditions not stated
unspecified
Source · OEM_SOURCE
Full load power: 5.0
Retrieved 2026-10-02
Gas Ballast Flow Manual Adj · Needs review · 1 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
0-50 l/min0 m3/hFrequency not stated · range
Conditions not stated
unspecified
Source · OEM_SOURCE
not a model rating
Gas ballast flow (Manual adj.): 0-50
Retrieved 2026-10-02
Maximum Exhaust Back Pressure · Needs review · 1 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
1.2 bara— Frequency not stated · model
Conditions not stated
unspecified
Source · OEM_SOURCE
Maximum exhaust back pressure: 1.2
Retrieved 2026-10-02
Maximum Rotor Speed · Needs review · 1 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
6600 Rev/min— Frequency not stated · model
Conditions not stated
unspecified
Source · OEM_SOURCE
Maximum rotor speed: 6600
Retrieved 2026-10-02
Maximum Supply Pressure · Needs review · 1 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
6.9 barg— Frequency not stated · model
Conditions not stated
unspecified
Source · OEM_SOURCE
Maximum supply pressure: 6.9
Retrieved 2026-10-02
Minimum Differential Pressure · Needs review · 1 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
1 bar1000 mbarFrequency not stated · model
Conditions not stated
unspecified
Source · OEM_SOURCE
Minimum differential pressure: 1
Retrieved 2026-10-02
Oil · Needs review · 1 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
PFPE Drynert 25/6 — Frequency not stated · model
Conditions not stated
unspecified
Source · OEM_SOURCE
Oil: PFPE Drynert 25/6
Retrieved 2026-10-02
Oil capacity · Sourced · 1 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
0.7 l0.7 lFrequency not stated · model
Conditions not stated
unspecified
Source · OEM_SOURCE
Oil volume: 0.7
Retrieved 2026-10-02
Power consumption · Sourced · 1 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
5.0 kW5 kWFrequency not stated · model
as printed: "Full load power"; 6.7 hp
unspecified
Source · OEM_SOURCE
Full load power | kW (hp) | 5.0 (6.7) | 7.4 (9.9) | 9.0 (12.1) | 9.7 (13.0)
Retrieved 2026-10-20
Pressure · Needs review · 1 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
2.5-6.9 barg— Frequency not stated · range
Conditions not stated
unspecified
Source · OEM_SOURCE
not a model rating
Pressure: 2.5-6.9
Retrieved 2026-10-02
Shaft Seal Flow Always On · Needs review · 1 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
12 l/min0.72 m3/hFrequency not stated · model
Conditions not stated
unspecified
Source · OEM_SOURCE
Shaft seal flow (Always on): 12
Retrieved 2026-10-02
Temperature · Needs review · 1 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
5-40 °C5 °CFrequency not stated · range
Conditions not stated
unspecified
Source · OEM_SOURCE
not a model rating
Temperature: 5-40
Retrieved 2026-10-02
Ultimate Power · Needs review · 1 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
3.8 kW3.8 kWFrequency not stated · model
Conditions not stated
unspecified
Source · OEM_SOURCE
Ultimate power: 3.8
Retrieved 2026-10-02

Operating-performance coverage

Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.

No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.

Document coverage

Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.

CategoryModel linksFamily linksPublic sources
Specifications00Not collected
Performance curves / test data00Not collected
Operation / service manuals00Not collected
Parts documentation00Not collected
Drawings / dimensions00Not collected
Product / family literature20