Data coverage & sources
The stored record for Edwards GV80: specifications, configurations, documents, sources, and gaps.
One model, connected records
Edwards → GV Series Dry Vacuum Pumps → GV80
Manufacturer model: GV80 · OEM article / order number: Not collected · Equipment type: vacuum pump
Technology: Claw
Related applications: Central Vacuum, CNC Routing, Medical Suction, Packaging, Pick + Place, Pneumatic Conveying, Vacuum Forming, Vacuum Hold-Down
Related industries: Electronics, Food + Beverage, General Manufacturing, Medical, Packaging, Plastics, Woodworking + CNC
These are technology associations. Check the operating point and process requirements to establish suitability for this model.
Compare coverage across this familySpecifications and evidence
34 stored observations · 9 pass the source policy at 50 Hz. Individual ratings do not establish flow at a requested pressure.
The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.
Pumping speed · Sourced · 2 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 80 m3/hr | 80 m3/h | 50 Hz · model 50 Hz; 50 Hz Peak pumping speed 50 Hz unspecified | Source · OEM_SOURCEPeak pumping speed 50 Hz Peak pumping speed 50 Hz: 80Retrieved 2026-10-02 |
| 94 m3/hr | 94 m3/h | 60 Hz · model 60 Hz; 60 Hz Peak pumping speed 60 Hz unspecified | Source · OEM_SOURCE different frequency Peak pumping speed 60 Hz Peak pumping speed 60 Hz: 94Retrieved 2026-10-02 |
Ultimate pressure · Needs review · 1 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| <3 x 10 -2 mbar | 0.03 mbar | Frequency not stated · range Conditions not stated unspecified | Source · OEM_SOURCE not a model rating Ultimate pressure: <3 x 10 -2Retrieved 2026-10-02 |
Motor power · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Speed · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Noise level · Sourced · 1 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| <78 dB(A) | 78 dB(A) | Frequency not stated · model with exhaust silencer unspecified | Source · OEM_SOURCENoise level with exhaust silencer: <78Retrieved 2026-10-02 |
Weight · Sourced · 1 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 165 Kg | 165 kg | Frequency not stated · model Conditions not stated unspecified | Source · OEM_SOURCEWeight: 165Retrieved 2026-10-02 |
Dimensions · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Inlet connection · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Outlet connection · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Ambient Operating Temperature Range · Needs review · 1 observations / 1 sources · classification pending
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 0 to 40 °C | 0 °C | Frequency not stated · range Conditions not stated unspecified | Source · OEM_SOURCE not a model rating Ambient operating temperature range: 0 to 40Retrieved 2026-10-02 |
Cooling · Needs review · 1 observations / 1 sources · classification pending
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| Water | — | Frequency not stated · model Conditions not stated unspecified | Source · OEM_SOURCECooling: WaterRetrieved 2026-10-02 |
Exhaust Back Pressure Max · Needs review · 1 observations / 1 sources · classification pending
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 1.3 bar.a | — | Frequency not stated · model Conditions not stated unspecified | Source · OEM_SOURCEExhaust Back Pressure (MAX): 1.3Retrieved 2026-10-02 |
Footprint · Needs review · 1 observations / 1 sources · classification pending
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 0.43 m2 | — | Frequency not stated · model Conditions not stated unspecified | Source · OEM_SOURCEFootprint: 0.43Retrieved 2026-10-02 |
Full Load Power Peak Pumping Load · Needs review · 1 observations / 1 sources · classification pending
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 5.8 Kw | 5.8 kW | Frequency not stated · model Conditions not stated unspecified | Source · OEM_SOURCEFull load power @ peak pumping load: 5.8Retrieved 2026-10-02 |
Full Load Power Ultimate Pressure · Needs review · 1 observations / 1 sources · classification pending
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 3.6 Kw | 3.6 kW | Frequency not stated · model Conditions not stated unspecified | Source · OEM_SOURCEFull load power @ ultimate pressure: 3.6Retrieved 2026-10-02 |
L X W X H · Needs review · 1 observations / 1 sources · classification pending
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 860 x 607 x 344 mm | — | Frequency not stated · model Conditions not stated unspecified | Source · OEM_SOURCEL x W x H: 860 x 607 x 344Retrieved 2026-10-02 |
Maximum Ambient Operating Humidity · Needs review · 1 observations / 1 sources · classification pending
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 100% % RH | — | Frequency not stated · model Conditions not stated unspecified | Source · OEM_SOURCEMaximum ambient operating humidity: 100%Retrieved 2026-10-02 |
Power consumption · Sourced · 1 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 5.8 Kw | 5.8 kW | Frequency not stated · model as printed: "Full load power @ peak pumping load"; 7.8 hp unspecified | Source · OEM_SOURCE@ peak pumping load | Kw (hp) | 4.5 kW (4.7) | 5.8 (7.8) | 6.7 (9.0)Retrieved 2026-10-20 |
Protection Grade · Needs review · 1 observations / 1 sources · classification pending
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 55 IP | — | Frequency not stated · model Conditions not stated unspecified | Source · OEM_SOURCEProtection grade: 55Retrieved 2026-10-02 |
Pump Electrical Motor Rating · Needs review · 1 observations / 1 sources · classification pending
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 4 kW | 4 kW | Frequency not stated · model Conditions not stated unspecified | Source · OEM_SOURCEPump Electrical motor rating: 4Retrieved 2026-10-02 |
Purge Gas N2 Or Cda Connection · Needs review · 1 observations / 1 sources · classification pending
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 1/4" Quick connect coupling (mating half provided) /4" Quick connect coupling (mating half provided) | — | Frequency not stated · model Conditions not stated unspecified | Source · OEM_SOURCEPurge gas (N2 or CDA) Connection: 1/4" Quick connect coupling (mating half provided)Retrieved 2026-10-02 |
Purge Gas N2 Or Cda Light Duty · Needs review · 1 observations / 1 sources · classification pending
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 15 (typically) (typically) sl/min | — | Frequency not stated · model Conditions not stated unspecified | Source · OEM_SOURCEPurge gas (N2 or CDA) Light duty: 15 (typically)Retrieved 2026-10-02 |
Purge Gas N2 Or Cda Pressure · Needs review · 1 observations / 1 sources · classification pending
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 0.5 bar.a | — | Frequency not stated · model Conditions not stated unspecified | Source · OEM_SOURCEPurge gas (N2 or CDA) Pressure: 0.5Retrieved 2026-10-02 |
Service liquid flow · Sourced · 6 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 8 l/min | 0.48 m3/h | Frequency not stated · model Flow unspecified | Source · OEM_SOURCECooling water Flow: 8Retrieved 2026-10-02 |
| 8 bar.a | — | Frequency not stated · model Supply pressure (MAX) unspecified | Source · OEM_SOURCECooling water Supply pressure (MAX): 8Retrieved 2026-10-02 |
| 2.1 bar.a | — | Frequency not stated · model DP across pump (MIN) unspecified | Source · OEM_SOURCECooling water DP across pump (MIN): 2.1Retrieved 2026-10-02 |
| 5 - 35 °C | 5 °C | Frequency not stated · range Temperature unspecified | Source · OEM_SOURCE not a model rating Cooling water Temperature: 5 - 35Retrieved 2026-10-02 |
| 1/2" Quick connect coupling (mating half provided) /2" Quick connect coupling (mating half provided) In | — | Frequency not stated · model Connection unspecified | Source · OEM_SOURCECooling water Connection: 1/2" Quick connect coupling (mating half provided)Retrieved 2026-10-02 |
| 1/2" Quick connect plug (mating half provided) /2" Quick connect plug (mating half provided) Out | — | Frequency not stated · model Conditions not stated unspecified | Source · OEM_SOURCECooling water: 1/2" Quick connect plug (mating half provided)Retrieved 2026-10-02 |
Supply Options · Needs review · 1 observations / 1 sources · classification pending
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| EU-US-CN 50/60Hz, 400V/50Hz - 460V/60Hz - 380V/50Hz ASIA 50/60 Hz 200V/50Hz, 200V/60Hz, 380V/60Hz Note: See part number for specific voltage offerings. EU-US-CN 50/60Hz, 400V/50Hz - 460V/60Hz - 380V/50Hz ASIA 50/60 Hz 200V/50Hz, 200V/60Hz, 380V/60Hz Note: See part number for specific voltage offerings. | — | Frequency not stated · model Conditions not stated unspecified | Source · OEM_SOURCESupply options: EU-US-CN 50/60Hz, 400V/50Hz - 460V/60Hz - 380V/50Hz ASIA 50/60 Hz 200V/50Hz, 200V/60Hz, 380V/60Hz Note: See part number for specific voltage offerings.Retrieved 2026-10-02 |
Type · Needs review · 2 observations / 1 sources · classification pending
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| SHC 629 Hydrocarbon | — | Frequency not stated · model Conditions not stated unspecified | Source · OEM_SOURCEType: SHC 629Retrieved 2026-10-02 |
| YVAC 25/6 PFPE | — | Frequency not stated · model Conditions not stated unspecified | Source · OEM_SOURCEType: YVAC 25/6Retrieved 2026-10-02 |
Typical Pump Rotation Speed 50hz Electrical Supply · Needs review · 1 observations / 1 sources · classification pending
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 3000 rev.min-1 | — | 50 Hz · model 50 Hz unspecified | Source · OEM_SOURCETypical pump rotation speed - 50Hz electrical supply: 3000Retrieved 2026-10-02 |
Typical Pump Rotation Speed 60hz Electrical Supply · Needs review · 1 observations / 1 sources · classification pending
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 3600 rev.min-1 | — | 60 Hz · model 60 Hz unspecified | Source · OEM_SOURCE different frequency Typical pump rotation speed - 60Hz electrical supply: 3600Retrieved 2026-10-02 |
Vacuum Couplings Exhaust · Needs review · 1 observations / 1 sources · classification pending
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| NW40 | — | Frequency not stated · model Conditions not stated unspecified | Source · OEM_SOURCEVacuum couplings Exhaust: NW40Retrieved 2026-10-02 |
Vacuum Couplings Inlet · Needs review · 1 observations / 1 sources · classification pending
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| ISO40 | — | Frequency not stated · model Conditions not stated unspecified | Source · OEM_SOURCEVacuum couplings Inlet: ISO40Retrieved 2026-10-02 |
Volume · Needs review · 1 observations / 1 sources · classification pending
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 0.4 l | 0.4 l | Frequency not stated · model Conditions not stated unspecified | Source · OEM_SOURCEVolume: 0.4Retrieved 2026-10-02 |
Warm Up Time To Pump Operating Temperature · Needs review · 1 observations / 1 sources · classification pending
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 15 min | — | Frequency not stated · model Conditions not stated unspecified | Source · OEM_SOURCEWarm-up time to pump operating temperature: 15Retrieved 2026-10-02 |
Operating-performance coverage
Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.
No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.
Document coverage
Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.
| Category | Model links | Family links | Public sources |
|---|---|---|---|
| Specifications | 0 | 0 | Not collected |
| Performance curves / test data | 0 | 0 | Not collected |
| Operation / service manuals | 0 | 0 | Not collected |
| Parts documentation | 0 | 0 | Not collected |
| Drawings / dimensions | 0 | 0 | Not collected |
| Product / family literature | 1 | 0 |
|
| Other / unclassified | 0 | 0 | Not collected |