Find equipmentComparePartsManufacturersTechnologiesIndustriesApplicationsAsset trackingMy equipmentTalk to a specialist

Data coverage & sources

The stored record for Edwards GV80: specifications, configurations, documents, sources, and gaps.

One model, connected records

Edwards → GV Series Dry Vacuum Pumps → GV80

Manufacturer model: GV80 · OEM article / order number: Not collected · Equipment type: vacuum pump

Technology: Claw

Related applications: Central Vacuum, CNC Routing, Medical Suction, Packaging, Pick + Place, Pneumatic Conveying, Vacuum Forming, Vacuum Hold-Down
Related industries: Electronics, Food + Beverage, General Manufacturing, Medical, Packaging, Plastics, Woodworking + CNC

These are technology associations. Check the operating point and process requirements to establish suitability for this model.

Compare coverage across this family

Specifications and evidence

34 stored observations · 9 pass the source policy at 50 Hz. Individual ratings do not establish flow at a requested pressure.

The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.

Pumping speed · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
80 m3/hr80 m3/h50 Hz · model
50 Hz; 50 Hz Peak pumping speed 50 Hz
unspecified
Source · OEM_SOURCE
Peak pumping speed 50 Hz Peak pumping speed 50 Hz: 80
Retrieved 2026-10-02
94 m3/hr94 m3/h60 Hz · model
60 Hz; 60 Hz Peak pumping speed 60 Hz
unspecified
Source · OEM_SOURCE
different frequency
Peak pumping speed 60 Hz Peak pumping speed 60 Hz: 94
Retrieved 2026-10-02
Ultimate pressure · Needs review · 1 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
<3 x 10 -2 mbar0.03 mbarFrequency not stated · range
Conditions not stated
unspecified
Source · OEM_SOURCE
not a model rating
Ultimate pressure: <3 x 10 -2
Retrieved 2026-10-02
Motor power · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Speed · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Noise level · Sourced · 1 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
<78 dB(A)78 dB(A)Frequency not stated · model
with exhaust silencer
unspecified
Source · OEM_SOURCE
Noise level with exhaust silencer: <78
Retrieved 2026-10-02
Weight · Sourced · 1 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
165 Kg165 kgFrequency not stated · model
Conditions not stated
unspecified
Source · OEM_SOURCE
Weight: 165
Retrieved 2026-10-02
Dimensions · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Inlet connection · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Outlet connection · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Ambient Operating Temperature Range · Needs review · 1 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
0 to 40 °C0 °CFrequency not stated · range
Conditions not stated
unspecified
Source · OEM_SOURCE
not a model rating
Ambient operating temperature range: 0 to 40
Retrieved 2026-10-02
Cooling · Needs review · 1 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
Water — Frequency not stated · model
Conditions not stated
unspecified
Source · OEM_SOURCE
Cooling: Water
Retrieved 2026-10-02
Exhaust Back Pressure Max · Needs review · 1 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
1.3 bar.a— Frequency not stated · model
Conditions not stated
unspecified
Source · OEM_SOURCE
Exhaust Back Pressure (MAX): 1.3
Retrieved 2026-10-02
Footprint · Needs review · 1 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
0.43 m2— Frequency not stated · model
Conditions not stated
unspecified
Source · OEM_SOURCE
Footprint: 0.43
Retrieved 2026-10-02
Full Load Power Peak Pumping Load · Needs review · 1 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
5.8 Kw5.8 kWFrequency not stated · model
Conditions not stated
unspecified
Source · OEM_SOURCE
Full load power @ peak pumping load: 5.8
Retrieved 2026-10-02
Full Load Power Ultimate Pressure · Needs review · 1 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
3.6 Kw3.6 kWFrequency not stated · model
Conditions not stated
unspecified
Source · OEM_SOURCE
Full load power @ ultimate pressure: 3.6
Retrieved 2026-10-02
L X W X H · Needs review · 1 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
860 x 607 x 344 mm— Frequency not stated · model
Conditions not stated
unspecified
Source · OEM_SOURCE
L x W x H: 860 x 607 x 344
Retrieved 2026-10-02
Maximum Ambient Operating Humidity · Needs review · 1 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
100% % RH— Frequency not stated · model
Conditions not stated
unspecified
Source · OEM_SOURCE
Maximum ambient operating humidity: 100%
Retrieved 2026-10-02
Power consumption · Sourced · 1 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
5.8 Kw5.8 kWFrequency not stated · model
as printed: "Full load power @ peak pumping load"; 7.8 hp
unspecified
Source · OEM_SOURCE
@ peak pumping load | Kw (hp) | 4.5 kW (4.7) | 5.8 (7.8) | 6.7 (9.0)
Retrieved 2026-10-20
Protection Grade · Needs review · 1 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
55 IP— Frequency not stated · model
Conditions not stated
unspecified
Source · OEM_SOURCE
Protection grade: 55
Retrieved 2026-10-02
Pump Electrical Motor Rating · Needs review · 1 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
4 kW4 kWFrequency not stated · model
Conditions not stated
unspecified
Source · OEM_SOURCE
Pump Electrical motor rating: 4
Retrieved 2026-10-02
Purge Gas N2 Or Cda Connection · Needs review · 1 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
1/4" Quick connect coupling (mating half provided) /4" Quick connect coupling (mating half provided)— Frequency not stated · model
Conditions not stated
unspecified
Source · OEM_SOURCE
Purge gas (N2 or CDA) Connection: 1/4" Quick connect coupling (mating half provided)
Retrieved 2026-10-02
Purge Gas N2 Or Cda Light Duty · Needs review · 1 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
15 (typically) (typically) sl/min— Frequency not stated · model
Conditions not stated
unspecified
Source · OEM_SOURCE
Purge gas (N2 or CDA) Light duty: 15 (typically)
Retrieved 2026-10-02
Purge Gas N2 Or Cda Pressure · Needs review · 1 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
0.5 bar.a— Frequency not stated · model
Conditions not stated
unspecified
Source · OEM_SOURCE
Purge gas (N2 or CDA) Pressure: 0.5
Retrieved 2026-10-02
Service liquid flow · Sourced · 6 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
8 l/min0.48 m3/hFrequency not stated · model
Flow
unspecified
Source · OEM_SOURCE
Cooling water Flow: 8
Retrieved 2026-10-02
8 bar.a— Frequency not stated · model
Supply pressure (MAX)
unspecified
Source · OEM_SOURCE
Cooling water Supply pressure (MAX): 8
Retrieved 2026-10-02
2.1 bar.a— Frequency not stated · model
DP across pump (MIN)
unspecified
Source · OEM_SOURCE
Cooling water DP across pump (MIN): 2.1
Retrieved 2026-10-02
5 - 35 °C5 °CFrequency not stated · range
Temperature
unspecified
Source · OEM_SOURCE
not a model rating
Cooling water Temperature: 5 - 35
Retrieved 2026-10-02
1/2" Quick connect coupling (mating half provided) /2" Quick connect coupling (mating half provided) In— Frequency not stated · model
Connection
unspecified
Source · OEM_SOURCE
Cooling water Connection: 1/2" Quick connect coupling (mating half provided)
Retrieved 2026-10-02
1/2" Quick connect plug (mating half provided) /2" Quick connect plug (mating half provided) Out— Frequency not stated · model
Conditions not stated
unspecified
Source · OEM_SOURCE
Cooling water: 1/2" Quick connect plug (mating half provided)
Retrieved 2026-10-02
Supply Options · Needs review · 1 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
EU-US-CN 50/60Hz, 400V/50Hz - 460V/60Hz - 380V/50Hz ASIA 50/60 Hz 200V/50Hz, 200V/60Hz, 380V/60Hz Note: See part number for specific voltage offerings. EU-US-CN 50/60Hz, 400V/50Hz - 460V/60Hz - 380V/50Hz ASIA 50/60 Hz 200V/50Hz, 200V/60Hz, 380V/60Hz Note: See part number for specific voltage offerings.— Frequency not stated · model
Conditions not stated
unspecified
Source · OEM_SOURCE
Supply options: EU-US-CN 50/60Hz, 400V/50Hz - 460V/60Hz - 380V/50Hz ASIA 50/60 Hz 200V/50Hz, 200V/60Hz, 380V/60Hz Note: See part number for specific voltage offerings.
Retrieved 2026-10-02
Type · Needs review · 2 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
SHC 629 Hydrocarbon— Frequency not stated · model
Conditions not stated
unspecified
Source · OEM_SOURCE
Type: SHC 629
Retrieved 2026-10-02
YVAC 25/6 PFPE— Frequency not stated · model
Conditions not stated
unspecified
Source · OEM_SOURCE
Type: YVAC 25/6
Retrieved 2026-10-02
Typical Pump Rotation Speed 50hz Electrical Supply · Needs review · 1 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
3000 rev.min-1— 50 Hz · model
50 Hz
unspecified
Source · OEM_SOURCE
Typical pump rotation speed - 50Hz electrical supply: 3000
Retrieved 2026-10-02
Typical Pump Rotation Speed 60hz Electrical Supply · Needs review · 1 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
3600 rev.min-1— 60 Hz · model
60 Hz
unspecified
Source · OEM_SOURCE
different frequency
Typical pump rotation speed - 60Hz electrical supply: 3600
Retrieved 2026-10-02
Vacuum Couplings Exhaust · Needs review · 1 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
NW40 — Frequency not stated · model
Conditions not stated
unspecified
Source · OEM_SOURCE
Vacuum couplings Exhaust: NW40
Retrieved 2026-10-02
Vacuum Couplings Inlet · Needs review · 1 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
ISO40 — Frequency not stated · model
Conditions not stated
unspecified
Source · OEM_SOURCE
Vacuum couplings Inlet: ISO40
Retrieved 2026-10-02
Volume · Needs review · 1 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
0.4 l0.4 lFrequency not stated · model
Conditions not stated
unspecified
Source · OEM_SOURCE
Volume: 0.4
Retrieved 2026-10-02
Warm Up Time To Pump Operating Temperature · Needs review · 1 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
15 min— Frequency not stated · model
Conditions not stated
unspecified
Source · OEM_SOURCE
Warm-up time to pump operating temperature: 15
Retrieved 2026-10-02

Operating-performance coverage

Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.

No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.

Document coverage

Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.

CategoryModel linksFamily linksPublic sources
Specifications00Not collected
Performance curves / test data00Not collected
Operation / service manuals00Not collected
Parts documentation00Not collected
Drawings / dimensions00Not collected
Product / family literature10
Other / unclassified00Not collected