Find equipmentComparePartsManufacturersTechnologiesIndustriesApplicationsAsset trackingMy equipmentTalk to a specialist

Data coverage & sources

The stored record for Edwards nES100: specifications, configurations, documents, sources, and gaps.

One model, connected records

Edwards → nES Single Stage Rotary Vane Pumps → nES100

Manufacturer model: nES100 · OEM article / order number: Not collected · Equipment type: vacuum pump

Technology: Oil-Lubricated Rotary Vane

Related applications: Central Vacuum, Degassing, Drying, Leak Testing, Medical Suction, Packaging, Vacuum Forming
Related industries: Automotive, Food + Beverage, Medical, Metalworking, Packaging, Plastics

These are technology associations. Check the operating point and process requirements to establish suitability for this model.

Compare coverage across this family

Specifications and evidence

21 stored observations · 9 pass the source policy at 50 Hz. Individual ratings do not establish flow at a requested pressure.

The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.

Pumping speed · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
87.5 m3h-187.5 m3/h50 Hz · model
50 Hz; (50 Hz)
unspecified
Source · OEM_SOURCE
Pumping speed (50 Hz): 87.5
Retrieved 2026-10-02
105 m3h-1105 m3/h60 Hz · model
60 Hz; (60Hz)
unspecified
Source · OEM_SOURCE
different frequency
Pumping speed (60Hz): 105
Retrieved 2026-10-02
Ultimate pressure · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
0.5 mbar0.5 mbarFrequency not stated · model
without gas ballast
unspecified
Source · OEM_SOURCE
Ultimate vacuum without gas ballast: 0.5
Retrieved 2026-10-02
1.5 mbar1.5 mbarFrequency not stated · model
with gas ballast
unspecified
Source · OEM_SOURCE
Ultimate vacuum with gas ballast: 1.5
Retrieved 2026-10-02
Motor power · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
3 kW3 kW50 Hz · model
50 Hz; (50Hz)
unspecified
Source · OEM_SOURCE
Motor rated power (50Hz): 3
Retrieved 2026-10-02
3.6 kW3.6 kW60 Hz · model
60 Hz; (60Hz)
unspecified
Source · OEM_SOURCE
different frequency
Motor rated power (60Hz): 3.6
Retrieved 2026-10-02
Speed · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Noise level · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
61 dB(A)61 dB(A)50 Hz · model
50 Hz; (50Hz) air/water
unspecified
Source · OEM_SOURCE
Noise level (50Hz) air/water: 61
Retrieved 2026-10-02
64 dB(A)64 dB(A)60 Hz · model
60 Hz; (60Hz) air/water
unspecified
Source · OEM_SOURCE
different frequency
Noise level (60Hz) air/water: 64
Retrieved 2026-10-02
Weight · Sourced · 1 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
104 kg104 kgFrequency not stated · model
approximate
unspecified
Source · OEM_SOURCE
Weight approximate: 104
Retrieved 2026-10-02
Dimensions · Sourced · 1 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
721x400x319 mm— Frequency not stated · model
(LxWxH) approximate
unspecified
Source · OEM_SOURCE
Dimensions (LxWxH) approximate: 721x400x319
Retrieved 2026-10-02
Inlet connection · Sourced · 1 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
40 ISO-F / G1 ¼ ISO-F / G1 ¼ ISO / G— Frequency not stated · model
Conditions not stated
unspecified
Source · OEM_SOURCE
Inlet connection: 40 ISO-F / G1 ¼
Retrieved 2026-10-02
Outlet connection · Sourced · 1 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
40 ISO-F / G1 ¼ ISO-F / G1 ¼ ISO / G— Frequency not stated · model
Conditions not stated
unspecified
Source · OEM_SOURCE
Outlet connection: 40 ISO-F / G1 ¼
Retrieved 2026-10-02
Cooling · Needs review · 1 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
air — Frequency not stated · model
Conditions not stated
unspecified
Source · OEM_SOURCE
Cooling: air
Retrieved 2026-10-02
Maximum Displacement 50hz · Needs review · 1 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
98.0 m3h-198 m3/h50 Hz · model
50 Hz
unspecified
Source · OEM_SOURCE
Maximum displacement (50Hz): 98.0
Retrieved 2026-10-02
Maximum Displacement 60hz · Needs review · 1 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
117 m3h-1117 m3/h60 Hz · model
60 Hz
unspecified
Source · OEM_SOURCE
different frequency
Maximum displacement (60Hz): 117
Retrieved 2026-10-02
Max Permitted Outlet Pressure · Needs review · 1 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
1.15 bar1150 mbarFrequency not stated · model
Conditions not stated
unspecified
Source · OEM_SOURCE
Max permitted outlet pressure: 1.15
Retrieved 2026-10-02
Max Water Vapour Pumping Rate 50hz · Needs review · 1 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
1.60/1.69 /1.69 kgh-1 / lbh-1— 50 Hz · model
50 Hz
unspecified
Source · OEM_SOURCE
Max water vapour pumping rate (50Hz): 1.60/1.69
Retrieved 2026-10-02
Max Water Vapour Pumping Rate 60hz · Needs review · 1 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
1.70/1.80 /1.80 kgh-1 / lbh-1— 60 Hz · model
60 Hz
unspecified
Source · OEM_SOURCE
different frequency
Max water vapour pumping rate (60Hz): 1.70/1.80
Retrieved 2026-10-02
Motor Protection Rating · Needs review · 1 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
IP55 — Frequency not stated · model
Conditions not stated
unspecified
Source · OEM_SOURCE
Motor protection rating: IP55
Retrieved 2026-10-02
Oil Refill Capacity · Needs review · 1 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
2 litre— Frequency not stated · model
Conditions not stated
unspecified
Source · OEM_SOURCE
Oil refill capacity: 2
Retrieved 2026-10-02
Recommended Oil · Needs review · 1 observations / 1 sources · classification pending
As publishedNormalizedConfiguration / scopeSource / status
Edwards ULTRAGRADE Performance 70 or ULTRAGRADE Endurance Extend 110 Edwards ULTRAGRADE Performance 70 or ULTRAGRADE Endurance Extend 110— Frequency not stated · model
Conditions not stated
unspecified
Source · OEM_SOURCE
Recommended oil: Edwards ULTRAGRADE Performance 70 or ULTRAGRADE Endurance Extend 110
Retrieved 2026-10-02

Operating-performance coverage

Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.

No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.

Document coverage

Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.

CategoryModel linksFamily linksPublic sources
Specifications00Not collected
Performance curves / test data00Not collected
Operation / service manuals00Not collected
Parts documentation00Not collected
Drawings / dimensions00Not collected
Product / family literature10