Find equipmentComparePartsManufacturersTechnologiesIndustriesApplicationsAsset trackingMy equipmentTalk to a specialist

Data coverage & sources

The stored record for Elektror SD 540: specifications, configurations, documents, sources, and gaps.

One model, connected records

Elektror → Elektror SD 540 → SD 540

Manufacturer model: SD 540 · OEM article / order number: Not collected · Equipment type: vacuum pump

Technology: Regenerative / Side Channel

Related applications: Material Handling, Pick + Place, Pneumatic Conveying, Vacuum Hold-Down
Related industries: Printing, Pulp + Paper, Woodworking + CNC

These are technology associations. Check the operating point and process requirements to establish suitability for this model.

Compare coverage across this family

Specifications and evidence

12 stored observations · 6 pass the source policy at 50 Hz. Individual ratings do not establish flow at a requested pressure.

The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.

Pumping speed · Sourced · 4 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
3,5 m³/min210 m3/h50 Hz · model
50 Hz; pressure; printed as Volume flow
unspecified
Source · OEM_SOURCE
Volume flow: 3,5
Retrieved 2026-10-06
3,5 m³/min210 m3/h50 Hz · model
50 Hz; vacuum (negative pressure); printed as Volume flow (negative pressure)
unspecified
Source · OEM_SOURCE
Volume flow: 3,5
Retrieved 2026-10-06
4,2 m³/min252 m3/h60 Hz · model
60 Hz; pressure; printed as Volume flow
unspecified
Source · OEM_SOURCE
different frequency
Volume flow: 4,2
Retrieved 2026-10-06
4,2 m³/min252 m3/h60 Hz · model
60 Hz; vacuum (negative pressure); printed as Volume flow (negative pressure)
unspecified
Source · OEM_SOURCE
different frequency
Volume flow: 4,2
Retrieved 2026-10-06
Ultimate pressure · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Motor power · Sourced · 3 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
3,1 — 60 Hz · model
as printed: "Performance (60 Hz, 255-300/440-520 V)"
unspecified
Source · OEM_SOURCE
different frequency
3,1
Retrieved 2026-10-20
2,4 — 50 Hz · model
as printed: "Performance (50 Hz, 207-253/360-440 V)"
unspecified
Source · OEM_SOURCE
2,4
Retrieved 2026-10-20
2,64 — 60 Hz · model
as printed: "Performance (60 Hz, 277/480 V)"
unspecified
Source · OEM_SOURCE
different frequency
2,64
Retrieved 2026-10-20
Speed · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Noise level · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Weight · Sourced · 1 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
35 — Frequency not stated · model
as printed: "Weight"
unspecified
Source · OEM_SOURCE
2855 35 60
Retrieved 2026-10-20
Dimensions · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Inlet connection · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Outlet connection · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Max. pressure · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
38000 Pa380 mbar50 Hz · model
50 Hz; pressure; printed as Total pressure difference
unspecified
Source · OEM_SOURCE
Δp max (compression): 38000
Retrieved 2026-10-06
38000 Pa380 mbar60 Hz · model
60 Hz; pressure; printed as Total pressure difference
unspecified
Source · OEM_SOURCE
different frequency
Δp max (compression): 38000
Retrieved 2026-10-06
Max. vacuum · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
29000 Pa290 mbar50 Hz · model
50 Hz; vacuum (negative pressure); printed as Total pressure difference (negative pressure)
unspecified
Source · OEM_SOURCE
Δp max (vacuum): 29000
Retrieved 2026-10-06
30000 Pa300 mbar60 Hz · model
60 Hz; vacuum (negative pressure); printed as Total pressure difference (negative pressure)
unspecified
Source · OEM_SOURCE
different frequency
Δp max (vacuum): 30000
Retrieved 2026-10-06

Operating-performance coverage

Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.

No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.

Document coverage

Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.

CategoryModel linksFamily linksPublic sources
Specifications00Not collected
Performance curves / test data00Not collected
Operation / service manuals00Not collected
Parts documentation00Not collected
Drawings / dimensions00Not collected
Product / family literature00Not collected
Other / unclassified80