Find equipmentComparePartsManufacturersTechnologiesIndustriesApplicationsAsset trackingMy equipmentTalk to a specialist

Data coverage & sources

The stored record for FPZ e07 MD: specifications, configurations, documents, sources, and gaps.

One model, connected records

FPZ → FPZ side channel blowers → e07 MD

Manufacturer model: e07 MD · OEM article / order number: Not collected · Equipment type: vacuum pump

Technology: Regenerative / Side Channel

Related applications: Material Handling, Pick + Place, Pneumatic Conveying, Vacuum Hold-Down
Related industries: Printing, Pulp + Paper, Woodworking + CNC

These are technology associations. Check the operating point and process requirements to establish suitability for this model.

Compare coverage across this family

Specifications and evidence

60 stored observations · 30 pass the source policy at 50 Hz. Individual ratings do not establish flow at a requested pressure.

The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.

Pumping speed · Sourced · 48 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
209 m³/h209 m3/h50 Hz · model
50 Hz; compression
unspecified
Source · OEM_SOURCE
Max. flow: 209
Retrieved 2026-10-05
197 m³/h197 m3/h50 Hz · model
50 Hz; compression; at +50 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 197
Retrieved 2026-10-05
186 m³/h186 m3/h50 Hz · model
50 Hz; compression; at +100 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 186
Retrieved 2026-10-05
175 m³/h175 m3/h50 Hz · model
50 Hz; compression; at +150 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 175
Retrieved 2026-10-05
164 m³/h164 m3/h50 Hz · model
50 Hz; compression; at +200 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 164
Retrieved 2026-10-05
153 m³/h153 m3/h50 Hz · model
50 Hz; compression; at +250 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 153
Retrieved 2026-10-05
143 m³/h143 m3/h50 Hz · model
50 Hz; compression; at +300 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 143
Retrieved 2026-10-05
133 m³/h133 m3/h50 Hz · model
50 Hz; compression; at +350 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 133
Retrieved 2026-10-05
124 m³/h124 m3/h50 Hz · model
50 Hz; compression; at +400 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 124
Retrieved 2026-10-05
114 m³/h114 m3/h50 Hz · model
50 Hz; compression; at +450 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 114
Retrieved 2026-10-05
105 m³/h105 m3/h50 Hz · model
50 Hz; compression; at +500 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 105
Retrieved 2026-10-05
96 m³/h96 m3/h50 Hz · model
50 Hz; compression; at +550 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 96
Retrieved 2026-10-05
88 m³/h88 m3/h50 Hz · model
50 Hz; compression; at +600 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 88
Retrieved 2026-10-05
80 m³/h80 m3/h50 Hz · model
50 Hz; compression; at +650 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 80
Retrieved 2026-10-05
209 m³/h209 m3/h50 Hz · model
50 Hz; vacuum
unspecified
Source · OEM_SOURCE
Max. flow: 209
Retrieved 2026-10-05
197 m³/h197 m3/h50 Hz · model
50 Hz; vacuum; at -50 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 197
Retrieved 2026-10-05
183 m³/h183 m3/h50 Hz · model
50 Hz; vacuum; at -100 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 183
Retrieved 2026-10-05
169 m³/h169 m3/h50 Hz · model
50 Hz; vacuum; at -150 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 169
Retrieved 2026-10-05
154 m³/h154 m3/h50 Hz · model
50 Hz; vacuum; at -200 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 154
Retrieved 2026-10-05
138 m³/h138 m3/h50 Hz · model
50 Hz; vacuum; at -250 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 138
Retrieved 2026-10-05
122 m³/h122 m3/h50 Hz · model
50 Hz; vacuum; at -300 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 122
Retrieved 2026-10-05
105 m³/h105 m3/h50 Hz · model
50 Hz; vacuum; at -350 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 105
Retrieved 2026-10-05
87 m³/h87 m3/h50 Hz · model
50 Hz; vacuum; at -400 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 87
Retrieved 2026-10-05
68 m³/h68 m3/h50 Hz · model
50 Hz; vacuum; at -450 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 68
Retrieved 2026-10-05
252 m³/h252 m3/h60 Hz · model
60 Hz; compression
unspecified
Source · OEM_SOURCE
different frequency
Max. flow: 252
Retrieved 2026-10-05
242 m³/h242 m3/h60 Hz · model
60 Hz; compression; at +50 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 242
Retrieved 2026-10-05
232 m³/h232 m3/h60 Hz · model
60 Hz; compression; at +100 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 232
Retrieved 2026-10-05
223 m³/h223 m3/h60 Hz · model
60 Hz; compression; at +150 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 223
Retrieved 2026-10-05
213 m³/h213 m3/h60 Hz · model
60 Hz; compression; at +200 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 213
Retrieved 2026-10-05
204 m³/h204 m3/h60 Hz · model
60 Hz; compression; at +250 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 204
Retrieved 2026-10-05
194 m³/h194 m3/h60 Hz · model
60 Hz; compression; at +300 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 194
Retrieved 2026-10-05
185 m³/h185 m3/h60 Hz · model
60 Hz; compression; at +350 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 185
Retrieved 2026-10-05
176 m³/h176 m3/h60 Hz · model
60 Hz; compression; at +400 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 176
Retrieved 2026-10-05
168 m³/h168 m3/h60 Hz · model
60 Hz; compression; at +450 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 168
Retrieved 2026-10-05
159 m³/h159 m3/h60 Hz · model
60 Hz; compression; at +500 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 159
Retrieved 2026-10-05
151 m³/h151 m3/h60 Hz · model
60 Hz; compression; at +550 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 151
Retrieved 2026-10-05
143 m³/h143 m3/h60 Hz · model
60 Hz; compression; at +600 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 143
Retrieved 2026-10-05
135 m³/h135 m3/h60 Hz · model
60 Hz; compression; at +650 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 135
Retrieved 2026-10-05
252 m³/h252 m3/h60 Hz · model
60 Hz; vacuum
unspecified
Source · OEM_SOURCE
different frequency
Max. flow: 252
Retrieved 2026-10-05
241 m³/h241 m3/h60 Hz · model
60 Hz; vacuum; at -50 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 241
Retrieved 2026-10-05
228 m³/h228 m3/h60 Hz · model
60 Hz; vacuum; at -100 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 228
Retrieved 2026-10-05
215 m³/h215 m3/h60 Hz · model
60 Hz; vacuum; at -150 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 215
Retrieved 2026-10-05
201 m³/h201 m3/h60 Hz · model
60 Hz; vacuum; at -200 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 201
Retrieved 2026-10-05
186 m³/h186 m3/h60 Hz · model
60 Hz; vacuum; at -250 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 186
Retrieved 2026-10-05
172 m³/h172 m3/h60 Hz · model
60 Hz; vacuum; at -300 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 172
Retrieved 2026-10-05
156 m³/h156 m3/h60 Hz · model
60 Hz; vacuum; at -350 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 156
Retrieved 2026-10-05
140 m³/h140 m3/h60 Hz · model
60 Hz; vacuum; at -400 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 140
Retrieved 2026-10-05
124 m³/h124 m3/h60 Hz · model
60 Hz; vacuum; at -450 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 124
Retrieved 2026-10-05
Ultimate pressure · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Motor power · Sourced · 8 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
3.00 kW3 kW50 Hz · model
50 Hz; compression; at max. flow
unspecified
Source · OEM_SOURCE
Installed motor size: 3.00
Retrieved 2026-10-05
5.50 kW5.5 kW50 Hz · model
50 Hz; compression; at Δp max 650 mbar
unspecified
Source · OEM_SOURCE
Installed motor size: 5.50
Retrieved 2026-10-05
3.00 kW3 kW50 Hz · model
50 Hz; vacuum; at max. flow
unspecified
Source · OEM_SOURCE
Installed motor size: 3.00
Retrieved 2026-10-05
4.00 kW4 kW50 Hz · model
50 Hz; vacuum; at Δp max 450 mbar
unspecified
Source · OEM_SOURCE
Installed motor size: 4.00
Retrieved 2026-10-05
3.00 kW3 kW60 Hz · model
60 Hz; compression; at max. flow
unspecified
Source · OEM_SOURCE
different frequency
Installed motor size: 3.00
Retrieved 2026-10-05
5.50 kW5.5 kW60 Hz · model
60 Hz; compression; at Δp max 650 mbar
unspecified
Source · OEM_SOURCE
different frequency
Installed motor size: 5.50
Retrieved 2026-10-05
3.00 kW3 kW60 Hz · model
60 Hz; vacuum; at max. flow
unspecified
Source · OEM_SOURCE
different frequency
Installed motor size: 3.00
Retrieved 2026-10-05
5.50 kW5.5 kW60 Hz · model
60 Hz; vacuum; at Δp max 450 mbar
unspecified
Source · OEM_SOURCE
different frequency
Installed motor size: 5.50
Retrieved 2026-10-05
Speed · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Noise level · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Weight · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Dimensions · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Inlet connection · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Outlet connection · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Max. pressure · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
650 mbar650 mbar50 Hz · model
50 Hz; compression
unspecified
Source · OEM_SOURCE
Δp max (compression): 650
Retrieved 2026-10-05
650 mbar650 mbar60 Hz · model
60 Hz; compression
unspecified
Source · OEM_SOURCE
different frequency
Δp max (compression): 650
Retrieved 2026-10-05
Max. vacuum · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
450 mbar450 mbar50 Hz · model
50 Hz; vacuum
unspecified
Source · OEM_SOURCE
Δp max (vacuum): 450
Retrieved 2026-10-05
450 mbar450 mbar60 Hz · model
60 Hz; vacuum
unspecified
Source · OEM_SOURCE
different frequency
Δp max (vacuum): 450
Retrieved 2026-10-05

Operating-performance coverage

Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.

No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.

Document coverage

Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.

CategoryModel linksFamily linksPublic sources
Specifications10
Performance curves / test data00Not collected
Operation / service manuals00Not collected
Parts documentation00Not collected
Drawings / dimensions00Not collected
Product / family literature10
Other / unclassified00Not collected