Data coverage & sources
The stored record for FPZ e08 MS: specifications, configurations, documents, sources, and gaps.
One model, connected records
FPZ → FPZ side channel blowers → e08 MS
Manufacturer model: e08 MS · OEM article / order number: Not collected · Equipment type: vacuum pump
Technology: Regenerative / Side Channel
Related applications: Material Handling, Pick + Place, Pneumatic Conveying, Vacuum Hold-Down
Related industries: Printing, Pulp + Paper, Woodworking + CNC
These are technology associations. Check the operating point and process requirements to establish suitability for this model.
Compare coverage across this familySpecifications and evidence
44 stored observations · 22 pass the source policy at 50 Hz. Individual ratings do not establish flow at a requested pressure.
The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.
Pumping speed · Sourced · 32 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 561 m³/h | 561 m3/h | 50 Hz · model 50 Hz; compression unspecified | Source · OEM_SOURCEMax. flow: 561Retrieved 2026-10-05 |
| 519 m³/h | 519 m3/h | 50 Hz · model 50 Hz; compression; at +50 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 519Retrieved 2026-10-05 |
| 478 m³/h | 478 m3/h | 50 Hz · model 50 Hz; compression; at +100 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 478Retrieved 2026-10-05 |
| 438 m³/h | 438 m3/h | 50 Hz · model 50 Hz; compression; at +150 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 438Retrieved 2026-10-05 |
| 399 m³/h | 399 m3/h | 50 Hz · model 50 Hz; compression; at +200 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 399Retrieved 2026-10-05 |
| 360 m³/h | 360 m3/h | 50 Hz · model 50 Hz; compression; at +250 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 360Retrieved 2026-10-05 |
| 322 m³/h | 322 m3/h | 50 Hz · model 50 Hz; compression; at +300 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 322Retrieved 2026-10-05 |
| 284 m³/h | 284 m3/h | 50 Hz · model 50 Hz; compression; at +350 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 284Retrieved 2026-10-05 |
| 248 m³/h | 248 m3/h | 50 Hz · model 50 Hz; compression; at +400 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 248Retrieved 2026-10-05 |
| 561 m³/h | 561 m3/h | 50 Hz · model 50 Hz; vacuum unspecified | Source · OEM_SOURCEMax. flow: 561Retrieved 2026-10-05 |
| 517 m³/h | 517 m3/h | 50 Hz · model 50 Hz; vacuum; at -50 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 517Retrieved 2026-10-05 |
| 468 m³/h | 468 m3/h | 50 Hz · model 50 Hz; vacuum; at -100 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 468Retrieved 2026-10-05 |
| 415 m³/h | 415 m3/h | 50 Hz · model 50 Hz; vacuum; at -150 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 415Retrieved 2026-10-05 |
| 360 m³/h | 360 m3/h | 50 Hz · model 50 Hz; vacuum; at -200 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 360Retrieved 2026-10-05 |
| 300 m³/h | 300 m3/h | 50 Hz · model 50 Hz; vacuum; at -250 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 300Retrieved 2026-10-05 |
| 238 m³/h | 238 m3/h | 50 Hz · model 50 Hz; vacuum; at -300 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 238Retrieved 2026-10-05 |
| 677 m³/h | 677 m3/h | 60 Hz · model 60 Hz; compression unspecified | Source · OEM_SOURCE different frequency Max. flow: 677Retrieved 2026-10-05 |
| 641 m³/h | 641 m3/h | 60 Hz · model 60 Hz; compression; at +50 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 641Retrieved 2026-10-05 |
| 605 m³/h | 605 m3/h | 60 Hz · model 60 Hz; compression; at +100 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 605Retrieved 2026-10-05 |
| 570 m³/h | 570 m3/h | 60 Hz · model 60 Hz; compression; at +150 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 570Retrieved 2026-10-05 |
| 536 m³/h | 536 m3/h | 60 Hz · model 60 Hz; compression; at +200 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 536Retrieved 2026-10-05 |
| 502 m³/h | 502 m3/h | 60 Hz · model 60 Hz; compression; at +250 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 502Retrieved 2026-10-05 |
| 468 m³/h | 468 m3/h | 60 Hz · model 60 Hz; compression; at +300 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 468Retrieved 2026-10-05 |
| 435 m³/h | 435 m3/h | 60 Hz · model 60 Hz; compression; at +350 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 435Retrieved 2026-10-05 |
| 402 m³/h | 402 m3/h | 60 Hz · model 60 Hz; compression; at +400 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 402Retrieved 2026-10-05 |
| 677 m³/h | 677 m3/h | 60 Hz · model 60 Hz; vacuum unspecified | Source · OEM_SOURCE different frequency Max. flow: 677Retrieved 2026-10-05 |
| 635 m³/h | 635 m3/h | 60 Hz · model 60 Hz; vacuum; at -50 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 635Retrieved 2026-10-05 |
| 590 m³/h | 590 m3/h | 60 Hz · model 60 Hz; vacuum; at -100 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 590Retrieved 2026-10-05 |
| 541 m³/h | 541 m3/h | 60 Hz · model 60 Hz; vacuum; at -150 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 541Retrieved 2026-10-05 |
| 491 m³/h | 491 m3/h | 60 Hz · model 60 Hz; vacuum; at -200 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 491Retrieved 2026-10-05 |
| 437 m³/h | 437 m3/h | 60 Hz · model 60 Hz; vacuum; at -250 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 437Retrieved 2026-10-05 |
| 381 m³/h | 381 m3/h | 60 Hz · model 60 Hz; vacuum; at -300 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 381Retrieved 2026-10-05 |
Ultimate pressure · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Motor power · Sourced · 8 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 3.00 kW | 3 kW | 50 Hz · model 50 Hz; compression; at max. flow unspecified | Source · OEM_SOURCEInstalled motor size: 3.00Retrieved 2026-10-05 |
| 9.20 kW | 9.2 kW | 50 Hz · model 50 Hz; compression; at Δp max 425 mbar unspecified | Source · OEM_SOURCEInstalled motor size: 9.20Retrieved 2026-10-05 |
| 3.00 kW | 3 kW | 50 Hz · model 50 Hz; vacuum; at max. flow unspecified | Source · OEM_SOURCEInstalled motor size: 3.00Retrieved 2026-10-05 |
| 7.50 kW | 7.5 kW | 50 Hz · model 50 Hz; vacuum; at Δp max 300 mbar unspecified | Source · OEM_SOURCEInstalled motor size: 7.50Retrieved 2026-10-05 |
| 3.00 kW | 3 kW | 60 Hz · model 60 Hz; compression; at max. flow unspecified | Source · OEM_SOURCE different frequency Installed motor size: 3.00Retrieved 2026-10-05 |
| 11.00 kW | 11 kW | 60 Hz · model 60 Hz; compression; at Δp max 425 mbar unspecified | Source · OEM_SOURCE different frequency Installed motor size: 11.00Retrieved 2026-10-05 |
| 3.00 kW | 3 kW | 60 Hz · model 60 Hz; vacuum; at max. flow unspecified | Source · OEM_SOURCE different frequency Installed motor size: 3.00Retrieved 2026-10-05 |
| 7.50 kW | 7.5 kW | 60 Hz · model 60 Hz; vacuum; at Δp max 300 mbar unspecified | Source · OEM_SOURCE different frequency Installed motor size: 7.50Retrieved 2026-10-05 |
Speed · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Noise level · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Weight · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Dimensions · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Inlet connection · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Outlet connection · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Max. pressure · Sourced · 2 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 425 mbar | 425 mbar | 50 Hz · model 50 Hz; compression unspecified | Source · OEM_SOURCEΔp max (compression): 425Retrieved 2026-10-05 |
| 425 mbar | 425 mbar | 60 Hz · model 60 Hz; compression unspecified | Source · OEM_SOURCE different frequency Δp max (compression): 425Retrieved 2026-10-05 |
Max. vacuum · Sourced · 2 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 300 mbar | 300 mbar | 50 Hz · model 50 Hz; vacuum unspecified | Source · OEM_SOURCEΔp max (vacuum): 300Retrieved 2026-10-05 |
| 300 mbar | 300 mbar | 60 Hz · model 60 Hz; vacuum unspecified | Source · OEM_SOURCE different frequency Δp max (vacuum): 300Retrieved 2026-10-05 |
Operating-performance coverage
Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.
No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.
Document coverage
Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.
| Category | Model links | Family links | Public sources |
|---|---|---|---|
| Specifications | 1 | 0 |
|
| Performance curves / test data | 0 | 0 | Not collected |
| Operation / service manuals | 0 | 0 | Not collected |
| Parts documentation | 0 | 0 | Not collected |
| Drawings / dimensions | 0 | 0 | Not collected |
| Product / family literature | 1 | 0 |
|
| Other / unclassified | 0 | 0 | Not collected |