Find equipmentComparePartsManufacturersTechnologiesIndustriesApplicationsAsset trackingMy equipmentTalk to a specialist

Data coverage & sources

The stored record for FPZ e08 MS: specifications, configurations, documents, sources, and gaps.

One model, connected records

FPZ → FPZ side channel blowers → e08 MS

Manufacturer model: e08 MS · OEM article / order number: Not collected · Equipment type: vacuum pump

Technology: Regenerative / Side Channel

Related applications: Material Handling, Pick + Place, Pneumatic Conveying, Vacuum Hold-Down
Related industries: Printing, Pulp + Paper, Woodworking + CNC

These are technology associations. Check the operating point and process requirements to establish suitability for this model.

Compare coverage across this family

Specifications and evidence

44 stored observations · 22 pass the source policy at 50 Hz. Individual ratings do not establish flow at a requested pressure.

The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.

Pumping speed · Sourced · 32 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
561 m³/h561 m3/h50 Hz · model
50 Hz; compression
unspecified
Source · OEM_SOURCE
Max. flow: 561
Retrieved 2026-10-05
519 m³/h519 m3/h50 Hz · model
50 Hz; compression; at +50 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 519
Retrieved 2026-10-05
478 m³/h478 m3/h50 Hz · model
50 Hz; compression; at +100 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 478
Retrieved 2026-10-05
438 m³/h438 m3/h50 Hz · model
50 Hz; compression; at +150 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 438
Retrieved 2026-10-05
399 m³/h399 m3/h50 Hz · model
50 Hz; compression; at +200 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 399
Retrieved 2026-10-05
360 m³/h360 m3/h50 Hz · model
50 Hz; compression; at +250 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 360
Retrieved 2026-10-05
322 m³/h322 m3/h50 Hz · model
50 Hz; compression; at +300 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 322
Retrieved 2026-10-05
284 m³/h284 m3/h50 Hz · model
50 Hz; compression; at +350 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 284
Retrieved 2026-10-05
248 m³/h248 m3/h50 Hz · model
50 Hz; compression; at +400 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 248
Retrieved 2026-10-05
561 m³/h561 m3/h50 Hz · model
50 Hz; vacuum
unspecified
Source · OEM_SOURCE
Max. flow: 561
Retrieved 2026-10-05
517 m³/h517 m3/h50 Hz · model
50 Hz; vacuum; at -50 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 517
Retrieved 2026-10-05
468 m³/h468 m3/h50 Hz · model
50 Hz; vacuum; at -100 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 468
Retrieved 2026-10-05
415 m³/h415 m3/h50 Hz · model
50 Hz; vacuum; at -150 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 415
Retrieved 2026-10-05
360 m³/h360 m3/h50 Hz · model
50 Hz; vacuum; at -200 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 360
Retrieved 2026-10-05
300 m³/h300 m3/h50 Hz · model
50 Hz; vacuum; at -250 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 300
Retrieved 2026-10-05
238 m³/h238 m3/h50 Hz · model
50 Hz; vacuum; at -300 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 238
Retrieved 2026-10-05
677 m³/h677 m3/h60 Hz · model
60 Hz; compression
unspecified
Source · OEM_SOURCE
different frequency
Max. flow: 677
Retrieved 2026-10-05
641 m³/h641 m3/h60 Hz · model
60 Hz; compression; at +50 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 641
Retrieved 2026-10-05
605 m³/h605 m3/h60 Hz · model
60 Hz; compression; at +100 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 605
Retrieved 2026-10-05
570 m³/h570 m3/h60 Hz · model
60 Hz; compression; at +150 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 570
Retrieved 2026-10-05
536 m³/h536 m3/h60 Hz · model
60 Hz; compression; at +200 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 536
Retrieved 2026-10-05
502 m³/h502 m3/h60 Hz · model
60 Hz; compression; at +250 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 502
Retrieved 2026-10-05
468 m³/h468 m3/h60 Hz · model
60 Hz; compression; at +300 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 468
Retrieved 2026-10-05
435 m³/h435 m3/h60 Hz · model
60 Hz; compression; at +350 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 435
Retrieved 2026-10-05
402 m³/h402 m3/h60 Hz · model
60 Hz; compression; at +400 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 402
Retrieved 2026-10-05
677 m³/h677 m3/h60 Hz · model
60 Hz; vacuum
unspecified
Source · OEM_SOURCE
different frequency
Max. flow: 677
Retrieved 2026-10-05
635 m³/h635 m3/h60 Hz · model
60 Hz; vacuum; at -50 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 635
Retrieved 2026-10-05
590 m³/h590 m3/h60 Hz · model
60 Hz; vacuum; at -100 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 590
Retrieved 2026-10-05
541 m³/h541 m3/h60 Hz · model
60 Hz; vacuum; at -150 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 541
Retrieved 2026-10-05
491 m³/h491 m3/h60 Hz · model
60 Hz; vacuum; at -200 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 491
Retrieved 2026-10-05
437 m³/h437 m3/h60 Hz · model
60 Hz; vacuum; at -250 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 437
Retrieved 2026-10-05
381 m³/h381 m3/h60 Hz · model
60 Hz; vacuum; at -300 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 381
Retrieved 2026-10-05
Ultimate pressure · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Motor power · Sourced · 8 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
3.00 kW3 kW50 Hz · model
50 Hz; compression; at max. flow
unspecified
Source · OEM_SOURCE
Installed motor size: 3.00
Retrieved 2026-10-05
9.20 kW9.2 kW50 Hz · model
50 Hz; compression; at Δp max 425 mbar
unspecified
Source · OEM_SOURCE
Installed motor size: 9.20
Retrieved 2026-10-05
3.00 kW3 kW50 Hz · model
50 Hz; vacuum; at max. flow
unspecified
Source · OEM_SOURCE
Installed motor size: 3.00
Retrieved 2026-10-05
7.50 kW7.5 kW50 Hz · model
50 Hz; vacuum; at Δp max 300 mbar
unspecified
Source · OEM_SOURCE
Installed motor size: 7.50
Retrieved 2026-10-05
3.00 kW3 kW60 Hz · model
60 Hz; compression; at max. flow
unspecified
Source · OEM_SOURCE
different frequency
Installed motor size: 3.00
Retrieved 2026-10-05
11.00 kW11 kW60 Hz · model
60 Hz; compression; at Δp max 425 mbar
unspecified
Source · OEM_SOURCE
different frequency
Installed motor size: 11.00
Retrieved 2026-10-05
3.00 kW3 kW60 Hz · model
60 Hz; vacuum; at max. flow
unspecified
Source · OEM_SOURCE
different frequency
Installed motor size: 3.00
Retrieved 2026-10-05
7.50 kW7.5 kW60 Hz · model
60 Hz; vacuum; at Δp max 300 mbar
unspecified
Source · OEM_SOURCE
different frequency
Installed motor size: 7.50
Retrieved 2026-10-05
Speed · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Noise level · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Weight · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Dimensions · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Inlet connection · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Outlet connection · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Max. pressure · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
425 mbar425 mbar50 Hz · model
50 Hz; compression
unspecified
Source · OEM_SOURCE
Δp max (compression): 425
Retrieved 2026-10-05
425 mbar425 mbar60 Hz · model
60 Hz; compression
unspecified
Source · OEM_SOURCE
different frequency
Δp max (compression): 425
Retrieved 2026-10-05
Max. vacuum · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
300 mbar300 mbar50 Hz · model
50 Hz; vacuum
unspecified
Source · OEM_SOURCE
Δp max (vacuum): 300
Retrieved 2026-10-05
300 mbar300 mbar60 Hz · model
60 Hz; vacuum
unspecified
Source · OEM_SOURCE
different frequency
Δp max (vacuum): 300
Retrieved 2026-10-05

Operating-performance coverage

Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.

No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.

Document coverage

Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.

CategoryModel linksFamily linksPublic sources
Specifications10
Performance curves / test data00Not collected
Operation / service manuals00Not collected
Parts documentation00Not collected
Drawings / dimensions00Not collected
Product / family literature10
Other / unclassified00Not collected