Data coverage & sources
The stored record for FPZ e08 TS: specifications, configurations, documents, sources, and gaps.
One model, connected records
FPZ → FPZ side channel blowers → e08 TS
Manufacturer model: e08 TS · OEM article / order number: Not collected · Equipment type: vacuum pump
Technology: Regenerative / Side Channel
Related applications: Material Handling, Pick + Place, Pneumatic Conveying, Vacuum Hold-Down
Related industries: Printing, Pulp + Paper, Woodworking + CNC
These are technology associations. Check the operating point and process requirements to establish suitability for this model.
Compare coverage across this familySpecifications and evidence
39 stored observations · 21 pass the source policy at 50 Hz. Individual ratings do not establish flow at a requested pressure.
The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.
Pumping speed · Sourced · 27 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 1012 m³/h | 1012 m3/h | 50 Hz · model 50 Hz; compression unspecified | Source · OEM_SOURCEMax. flow: 1012Retrieved 2026-10-05 |
| 957 m³/h | 957 m3/h | 50 Hz · model 50 Hz; compression; at +50 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 957Retrieved 2026-10-05 |
| 901 m³/h | 901 m3/h | 50 Hz · model 50 Hz; compression; at +100 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 901Retrieved 2026-10-05 |
| 843 m³/h | 843 m3/h | 50 Hz · model 50 Hz; compression; at +150 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 843Retrieved 2026-10-05 |
| 784 m³/h | 784 m3/h | 50 Hz · model 50 Hz; compression; at +200 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 784Retrieved 2026-10-05 |
| 723 m³/h | 723 m3/h | 50 Hz · model 50 Hz; compression; at +250 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 723Retrieved 2026-10-05 |
| 661 m³/h | 661 m3/h | 50 Hz · model 50 Hz; compression; at +300 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 661Retrieved 2026-10-05 |
| 598 m³/h | 598 m3/h | 50 Hz · model 50 Hz; compression; at +350 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 598Retrieved 2026-10-05 |
| 1012 m³/h | 1012 m3/h | 50 Hz · model 50 Hz; vacuum unspecified | Source · OEM_SOURCEMax. flow: 1012Retrieved 2026-10-05 |
| 948 m³/h | 948 m3/h | 50 Hz · model 50 Hz; vacuum; at -50 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 948Retrieved 2026-10-05 |
| 883 m³/h | 883 m3/h | 50 Hz · model 50 Hz; vacuum; at -100 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 883Retrieved 2026-10-05 |
| 808 m³/h | 808 m3/h | 50 Hz · model 50 Hz; vacuum; at -150 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 808Retrieved 2026-10-05 |
| 722 m³/h | 722 m3/h | 50 Hz · model 50 Hz; vacuum; at -200 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 722Retrieved 2026-10-05 |
| 625 m³/h | 625 m3/h | 50 Hz · model 50 Hz; vacuum; at -250 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 625Retrieved 2026-10-05 |
| 518 m³/h | 518 m3/h | 50 Hz · model 50 Hz; vacuum; at -300 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 518Retrieved 2026-10-05 |
| 1222 m³/h | 1222 m3/h | 60 Hz · model 60 Hz; compression unspecified | Source · OEM_SOURCE different frequency Max. flow: 1222Retrieved 2026-10-05 |
| 1174 m³/h | 1174 m3/h | 60 Hz · model 60 Hz; compression; at +50 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 1174Retrieved 2026-10-05 |
| 1126 m³/h | 1126 m3/h | 60 Hz · model 60 Hz; compression; at +100 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 1126Retrieved 2026-10-05 |
| 1078 m³/h | 1078 m3/h | 60 Hz · model 60 Hz; compression; at +150 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 1078Retrieved 2026-10-05 |
| 1028 m³/h | 1028 m3/h | 60 Hz · model 60 Hz; compression; at +200 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 1028Retrieved 2026-10-05 |
| 977 m³/h | 977 m3/h | 60 Hz · model 60 Hz; compression; at +250 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 977Retrieved 2026-10-05 |
| 1222 m³/h | 1222 m3/h | 60 Hz · model 60 Hz; vacuum unspecified | Source · OEM_SOURCE different frequency Max. flow: 1222Retrieved 2026-10-05 |
| 1159 m³/h | 1159 m3/h | 60 Hz · model 60 Hz; vacuum; at -50 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 1159Retrieved 2026-10-05 |
| 1101 m³/h | 1101 m3/h | 60 Hz · model 60 Hz; vacuum; at -100 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 1101Retrieved 2026-10-05 |
| 1034 m³/h | 1034 m3/h | 60 Hz · model 60 Hz; vacuum; at -150 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 1034Retrieved 2026-10-05 |
| 959 m³/h | 959 m3/h | 60 Hz · model 60 Hz; vacuum; at -200 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 959Retrieved 2026-10-05 |
| 877 m³/h | 877 m3/h | 60 Hz · model 60 Hz; vacuum; at -250 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 877Retrieved 2026-10-05 |
Ultimate pressure · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Motor power · Sourced · 8 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 7.50 kW | 7.5 kW | 50 Hz · model 50 Hz; compression; at max. flow unspecified | Source · OEM_SOURCEInstalled motor size: 7.50Retrieved 2026-10-05 |
| 15.00 kW | 15 kW | 50 Hz · model 50 Hz; compression; at Δp max 375 mbar unspecified | Source · OEM_SOURCEInstalled motor size: 15.00Retrieved 2026-10-05 |
| 7.50 kW | 7.5 kW | 50 Hz · model 50 Hz; vacuum; at max. flow unspecified | Source · OEM_SOURCEInstalled motor size: 7.50Retrieved 2026-10-05 |
| 15.00 kW | 15 kW | 50 Hz · model 50 Hz; vacuum; at Δp max 300 mbar unspecified | Source · OEM_SOURCEInstalled motor size: 15.00Retrieved 2026-10-05 |
| 7.50 kW | 7.5 kW | 60 Hz · model 60 Hz; compression; at max. flow unspecified | Source · OEM_SOURCE different frequency Installed motor size: 7.50Retrieved 2026-10-05 |
| 15.00 kW | 15 kW | 60 Hz · model 60 Hz; compression; at Δp max 250 mbar unspecified | Source · OEM_SOURCE different frequency Installed motor size: 15.00Retrieved 2026-10-05 |
| 7.50 kW | 7.5 kW | 60 Hz · model 60 Hz; vacuum; at max. flow unspecified | Source · OEM_SOURCE different frequency Installed motor size: 7.50Retrieved 2026-10-05 |
| 15.00 kW | 15 kW | 60 Hz · model 60 Hz; vacuum; at Δp max 275 mbar unspecified | Source · OEM_SOURCE different frequency Installed motor size: 15.00Retrieved 2026-10-05 |
Speed · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Noise level · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Weight · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Dimensions · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Inlet connection · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Outlet connection · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Max. pressure · Sourced · 2 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 375 mbar | 375 mbar | 50 Hz · model 50 Hz; compression unspecified | Source · OEM_SOURCEΔp max (compression): 375Retrieved 2026-10-05 |
| 250 mbar | 250 mbar | 60 Hz · model 60 Hz; compression unspecified | Source · OEM_SOURCE different frequency Δp max (compression): 250Retrieved 2026-10-05 |
Max. vacuum · Sourced · 2 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 300 mbar | 300 mbar | 50 Hz · model 50 Hz; vacuum unspecified | Source · OEM_SOURCEΔp max (vacuum): 300Retrieved 2026-10-05 |
| 275 mbar | 275 mbar | 60 Hz · model 60 Hz; vacuum unspecified | Source · OEM_SOURCE different frequency Δp max (vacuum): 275Retrieved 2026-10-05 |
Operating-performance coverage
Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.
No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.
Document coverage
Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.
| Category | Model links | Family links | Public sources |
|---|---|---|---|
| Specifications | 1 | 0 |
|
| Performance curves / test data | 0 | 0 | Not collected |
| Operation / service manuals | 0 | 0 | Not collected |
| Parts documentation | 0 | 0 | Not collected |
| Drawings / dimensions | 0 | 0 | Not collected |
| Product / family literature | 1 | 0 |
|
| Other / unclassified | 0 | 0 | Not collected |