Find equipmentComparePartsManufacturersTechnologiesIndustriesApplicationsAsset trackingMy equipmentTalk to a specialist

Data coverage & sources

The stored record for FPZ e08 TS: specifications, configurations, documents, sources, and gaps.

One model, connected records

FPZ → FPZ side channel blowers → e08 TS

Manufacturer model: e08 TS · OEM article / order number: Not collected · Equipment type: vacuum pump

Technology: Regenerative / Side Channel

Related applications: Material Handling, Pick + Place, Pneumatic Conveying, Vacuum Hold-Down
Related industries: Printing, Pulp + Paper, Woodworking + CNC

These are technology associations. Check the operating point and process requirements to establish suitability for this model.

Compare coverage across this family

Specifications and evidence

39 stored observations · 21 pass the source policy at 50 Hz. Individual ratings do not establish flow at a requested pressure.

The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.

Pumping speed · Sourced · 27 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
1012 m³/h1012 m3/h50 Hz · model
50 Hz; compression
unspecified
Source · OEM_SOURCE
Max. flow: 1012
Retrieved 2026-10-05
957 m³/h957 m3/h50 Hz · model
50 Hz; compression; at +50 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 957
Retrieved 2026-10-05
901 m³/h901 m3/h50 Hz · model
50 Hz; compression; at +100 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 901
Retrieved 2026-10-05
843 m³/h843 m3/h50 Hz · model
50 Hz; compression; at +150 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 843
Retrieved 2026-10-05
784 m³/h784 m3/h50 Hz · model
50 Hz; compression; at +200 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 784
Retrieved 2026-10-05
723 m³/h723 m3/h50 Hz · model
50 Hz; compression; at +250 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 723
Retrieved 2026-10-05
661 m³/h661 m3/h50 Hz · model
50 Hz; compression; at +300 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 661
Retrieved 2026-10-05
598 m³/h598 m3/h50 Hz · model
50 Hz; compression; at +350 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 598
Retrieved 2026-10-05
1012 m³/h1012 m3/h50 Hz · model
50 Hz; vacuum
unspecified
Source · OEM_SOURCE
Max. flow: 1012
Retrieved 2026-10-05
948 m³/h948 m3/h50 Hz · model
50 Hz; vacuum; at -50 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 948
Retrieved 2026-10-05
883 m³/h883 m3/h50 Hz · model
50 Hz; vacuum; at -100 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 883
Retrieved 2026-10-05
808 m³/h808 m3/h50 Hz · model
50 Hz; vacuum; at -150 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 808
Retrieved 2026-10-05
722 m³/h722 m3/h50 Hz · model
50 Hz; vacuum; at -200 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 722
Retrieved 2026-10-05
625 m³/h625 m3/h50 Hz · model
50 Hz; vacuum; at -250 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 625
Retrieved 2026-10-05
518 m³/h518 m3/h50 Hz · model
50 Hz; vacuum; at -300 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 518
Retrieved 2026-10-05
1222 m³/h1222 m3/h60 Hz · model
60 Hz; compression
unspecified
Source · OEM_SOURCE
different frequency
Max. flow: 1222
Retrieved 2026-10-05
1174 m³/h1174 m3/h60 Hz · model
60 Hz; compression; at +50 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 1174
Retrieved 2026-10-05
1126 m³/h1126 m3/h60 Hz · model
60 Hz; compression; at +100 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 1126
Retrieved 2026-10-05
1078 m³/h1078 m3/h60 Hz · model
60 Hz; compression; at +150 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 1078
Retrieved 2026-10-05
1028 m³/h1028 m3/h60 Hz · model
60 Hz; compression; at +200 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 1028
Retrieved 2026-10-05
977 m³/h977 m3/h60 Hz · model
60 Hz; compression; at +250 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 977
Retrieved 2026-10-05
1222 m³/h1222 m3/h60 Hz · model
60 Hz; vacuum
unspecified
Source · OEM_SOURCE
different frequency
Max. flow: 1222
Retrieved 2026-10-05
1159 m³/h1159 m3/h60 Hz · model
60 Hz; vacuum; at -50 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 1159
Retrieved 2026-10-05
1101 m³/h1101 m3/h60 Hz · model
60 Hz; vacuum; at -100 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 1101
Retrieved 2026-10-05
1034 m³/h1034 m3/h60 Hz · model
60 Hz; vacuum; at -150 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 1034
Retrieved 2026-10-05
959 m³/h959 m3/h60 Hz · model
60 Hz; vacuum; at -200 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 959
Retrieved 2026-10-05
877 m³/h877 m3/h60 Hz · model
60 Hz; vacuum; at -250 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 877
Retrieved 2026-10-05
Ultimate pressure · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Motor power · Sourced · 8 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
7.50 kW7.5 kW50 Hz · model
50 Hz; compression; at max. flow
unspecified
Source · OEM_SOURCE
Installed motor size: 7.50
Retrieved 2026-10-05
15.00 kW15 kW50 Hz · model
50 Hz; compression; at Δp max 375 mbar
unspecified
Source · OEM_SOURCE
Installed motor size: 15.00
Retrieved 2026-10-05
7.50 kW7.5 kW50 Hz · model
50 Hz; vacuum; at max. flow
unspecified
Source · OEM_SOURCE
Installed motor size: 7.50
Retrieved 2026-10-05
15.00 kW15 kW50 Hz · model
50 Hz; vacuum; at Δp max 300 mbar
unspecified
Source · OEM_SOURCE
Installed motor size: 15.00
Retrieved 2026-10-05
7.50 kW7.5 kW60 Hz · model
60 Hz; compression; at max. flow
unspecified
Source · OEM_SOURCE
different frequency
Installed motor size: 7.50
Retrieved 2026-10-05
15.00 kW15 kW60 Hz · model
60 Hz; compression; at Δp max 250 mbar
unspecified
Source · OEM_SOURCE
different frequency
Installed motor size: 15.00
Retrieved 2026-10-05
7.50 kW7.5 kW60 Hz · model
60 Hz; vacuum; at max. flow
unspecified
Source · OEM_SOURCE
different frequency
Installed motor size: 7.50
Retrieved 2026-10-05
15.00 kW15 kW60 Hz · model
60 Hz; vacuum; at Δp max 275 mbar
unspecified
Source · OEM_SOURCE
different frequency
Installed motor size: 15.00
Retrieved 2026-10-05
Speed · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Noise level · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Weight · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Dimensions · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Inlet connection · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Outlet connection · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Max. pressure · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
375 mbar375 mbar50 Hz · model
50 Hz; compression
unspecified
Source · OEM_SOURCE
Δp max (compression): 375
Retrieved 2026-10-05
250 mbar250 mbar60 Hz · model
60 Hz; compression
unspecified
Source · OEM_SOURCE
different frequency
Δp max (compression): 250
Retrieved 2026-10-05
Max. vacuum · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
300 mbar300 mbar50 Hz · model
50 Hz; vacuum
unspecified
Source · OEM_SOURCE
Δp max (vacuum): 300
Retrieved 2026-10-05
275 mbar275 mbar60 Hz · model
60 Hz; vacuum
unspecified
Source · OEM_SOURCE
different frequency
Δp max (vacuum): 275
Retrieved 2026-10-05

Operating-performance coverage

Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.

No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.

Document coverage

Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.

CategoryModel linksFamily linksPublic sources
Specifications10
Performance curves / test data00Not collected
Operation / service manuals00Not collected
Parts documentation00Not collected
Drawings / dimensions00Not collected
Product / family literature10
Other / unclassified00Not collected