Data coverage & sources
The stored record for FPZ e09 TD: specifications, configurations, documents, sources, and gaps.
One model, connected records
FPZ → FPZ side channel blowers → e09 TD
Manufacturer model: e09 TD · OEM article / order number: Not collected · Equipment type: vacuum pump
Technology: Regenerative / Side Channel
Related applications: Material Handling, Pick + Place, Pneumatic Conveying, Vacuum Hold-Down
Related industries: Printing, Pulp + Paper, Woodworking + CNC
These are technology associations. Check the operating point and process requirements to establish suitability for this model.
Compare coverage across this familySpecifications and evidence
58 stored observations · 29 pass the source policy at 50 Hz. Individual ratings do not establish flow at a requested pressure.
The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.
Pumping speed · Sourced · 46 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 670 m³/h | 670 m3/h | 50 Hz · model 50 Hz; compression unspecified | Source · OEM_SOURCEMax. flow: 670Retrieved 2026-10-05 |
| 646 m³/h | 646 m3/h | 50 Hz · model 50 Hz; compression; at +50 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 646Retrieved 2026-10-05 |
| 622 m³/h | 622 m3/h | 50 Hz · model 50 Hz; compression; at +100 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 622Retrieved 2026-10-05 |
| 599 m³/h | 599 m3/h | 50 Hz · model 50 Hz; compression; at +150 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 599Retrieved 2026-10-05 |
| 577 m³/h | 577 m3/h | 50 Hz · model 50 Hz; compression; at +200 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 577Retrieved 2026-10-05 |
| 555 m³/h | 555 m3/h | 50 Hz · model 50 Hz; compression; at +250 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 555Retrieved 2026-10-05 |
| 533 m³/h | 533 m3/h | 50 Hz · model 50 Hz; compression; at +300 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 533Retrieved 2026-10-05 |
| 512 m³/h | 512 m3/h | 50 Hz · model 50 Hz; compression; at +350 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 512Retrieved 2026-10-05 |
| 492 m³/h | 492 m3/h | 50 Hz · model 50 Hz; compression; at +400 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 492Retrieved 2026-10-05 |
| 472 m³/h | 472 m3/h | 50 Hz · model 50 Hz; compression; at +450 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 472Retrieved 2026-10-05 |
| 452 m³/h | 452 m3/h | 50 Hz · model 50 Hz; compression; at +500 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 452Retrieved 2026-10-05 |
| 434 m³/h | 434 m3/h | 50 Hz · model 50 Hz; compression; at +550 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 434Retrieved 2026-10-05 |
| 415 m³/h | 415 m3/h | 50 Hz · model 50 Hz; compression; at +600 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 415Retrieved 2026-10-05 |
| 670 m³/h | 670 m3/h | 50 Hz · model 50 Hz; vacuum unspecified | Source · OEM_SOURCEMax. flow: 670Retrieved 2026-10-05 |
| 646 m³/h | 646 m3/h | 50 Hz · model 50 Hz; vacuum; at -50 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 646Retrieved 2026-10-05 |
| 619 m³/h | 619 m3/h | 50 Hz · model 50 Hz; vacuum; at -100 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 619Retrieved 2026-10-05 |
| 589 m³/h | 589 m3/h | 50 Hz · model 50 Hz; vacuum; at -150 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 589Retrieved 2026-10-05 |
| 555 m³/h | 555 m3/h | 50 Hz · model 50 Hz; vacuum; at -200 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 555Retrieved 2026-10-05 |
| 518 m³/h | 518 m3/h | 50 Hz · model 50 Hz; vacuum; at -250 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 518Retrieved 2026-10-05 |
| 478 m³/h | 478 m3/h | 50 Hz · model 50 Hz; vacuum; at -300 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 478Retrieved 2026-10-05 |
| 434 m³/h | 434 m3/h | 50 Hz · model 50 Hz; vacuum; at -350 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 434Retrieved 2026-10-05 |
| 388 m³/h | 388 m3/h | 50 Hz · model 50 Hz; vacuum; at -400 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 388Retrieved 2026-10-05 |
| 337 m³/h | 337 m3/h | 50 Hz · model 50 Hz; vacuum; at -450 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 337Retrieved 2026-10-05 |
| 808 m³/h | 808 m3/h | 60 Hz · model 60 Hz; compression unspecified | Source · OEM_SOURCE different frequency Max. flow: 808Retrieved 2026-10-05 |
| 787 m³/h | 787 m3/h | 60 Hz · model 60 Hz; compression; at +50 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 787Retrieved 2026-10-05 |
| 767 m³/h | 767 m3/h | 60 Hz · model 60 Hz; compression; at +100 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 767Retrieved 2026-10-05 |
| 747 m³/h | 747 m3/h | 60 Hz · model 60 Hz; compression; at +150 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 747Retrieved 2026-10-05 |
| 727 m³/h | 727 m3/h | 60 Hz · model 60 Hz; compression; at +200 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 727Retrieved 2026-10-05 |
| 708 m³/h | 708 m3/h | 60 Hz · model 60 Hz; compression; at +250 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 708Retrieved 2026-10-05 |
| 688 m³/h | 688 m3/h | 60 Hz · model 60 Hz; compression; at +300 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 688Retrieved 2026-10-05 |
| 670 m³/h | 670 m3/h | 60 Hz · model 60 Hz; compression; at +350 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 670Retrieved 2026-10-05 |
| 651 m³/h | 651 m3/h | 60 Hz · model 60 Hz; compression; at +400 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 651Retrieved 2026-10-05 |
| 633 m³/h | 633 m3/h | 60 Hz · model 60 Hz; compression; at +450 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 633Retrieved 2026-10-05 |
| 615 m³/h | 615 m3/h | 60 Hz · model 60 Hz; compression; at +500 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 615Retrieved 2026-10-05 |
| 597 m³/h | 597 m3/h | 60 Hz · model 60 Hz; compression; at +550 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 597Retrieved 2026-10-05 |
| 580 m³/h | 580 m3/h | 60 Hz · model 60 Hz; compression; at +600 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 580Retrieved 2026-10-05 |
| 808 m³/h | 808 m3/h | 60 Hz · model 60 Hz; vacuum unspecified | Source · OEM_SOURCE different frequency Max. flow: 808Retrieved 2026-10-05 |
| 786 m³/h | 786 m3/h | 60 Hz · model 60 Hz; vacuum; at -50 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 786Retrieved 2026-10-05 |
| 761 m³/h | 761 m3/h | 60 Hz · model 60 Hz; vacuum; at -100 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 761Retrieved 2026-10-05 |
| 734 m³/h | 734 m3/h | 60 Hz · model 60 Hz; vacuum; at -150 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 734Retrieved 2026-10-05 |
| 704 m³/h | 704 m3/h | 60 Hz · model 60 Hz; vacuum; at -200 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 704Retrieved 2026-10-05 |
| 672 m³/h | 672 m3/h | 60 Hz · model 60 Hz; vacuum; at -250 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 672Retrieved 2026-10-05 |
| 637 m³/h | 637 m3/h | 60 Hz · model 60 Hz; vacuum; at -300 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 637Retrieved 2026-10-05 |
| 600 m³/h | 600 m3/h | 60 Hz · model 60 Hz; vacuum; at -350 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 600Retrieved 2026-10-05 |
| 560 m³/h | 560 m3/h | 60 Hz · model 60 Hz; vacuum; at -400 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 560Retrieved 2026-10-05 |
| 518 m³/h | 518 m3/h | 60 Hz · model 60 Hz; vacuum; at -450 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 518Retrieved 2026-10-05 |
Ultimate pressure · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Motor power · Sourced · 8 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 11.00 kW | 11 kW | 50 Hz · model 50 Hz; compression; at max. flow unspecified | Source · OEM_SOURCEInstalled motor size: 11.00Retrieved 2026-10-05 |
| 15.00 kW | 15 kW | 50 Hz · model 50 Hz; compression; at Δp max 600 mbar unspecified | Source · OEM_SOURCEInstalled motor size: 15.00Retrieved 2026-10-05 |
| 11.00 kW | 11 kW | 50 Hz · model 50 Hz; vacuum; at max. flow unspecified | Source · OEM_SOURCEInstalled motor size: 11.00Retrieved 2026-10-05 |
| 11.00 kW | 11 kW | 50 Hz · model 50 Hz; vacuum; at Δp max 450 mbar unspecified | Source · OEM_SOURCEInstalled motor size: 11.00Retrieved 2026-10-05 |
| 11.00 kW | 11 kW | 60 Hz · model 60 Hz; compression; at max. flow unspecified | Source · OEM_SOURCE different frequency Installed motor size: 11.00Retrieved 2026-10-05 |
| 18.50 kW | 18.5 kW | 60 Hz · model 60 Hz; compression; at Δp max 600 mbar unspecified | Source · OEM_SOURCE different frequency Installed motor size: 18.50Retrieved 2026-10-05 |
| 11.00 kW | 11 kW | 60 Hz · model 60 Hz; vacuum; at max. flow unspecified | Source · OEM_SOURCE different frequency Installed motor size: 11.00Retrieved 2026-10-05 |
| 15.00 kW | 15 kW | 60 Hz · model 60 Hz; vacuum; at Δp max 450 mbar unspecified | Source · OEM_SOURCE different frequency Installed motor size: 15.00Retrieved 2026-10-05 |
Speed · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Noise level · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Weight · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Dimensions · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Inlet connection · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Outlet connection · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Max. pressure · Sourced · 2 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 600 mbar | 600 mbar | 50 Hz · model 50 Hz; compression unspecified | Source · OEM_SOURCEΔp max (compression): 600Retrieved 2026-10-05 |
| 600 mbar | 600 mbar | 60 Hz · model 60 Hz; compression unspecified | Source · OEM_SOURCE different frequency Δp max (compression): 600Retrieved 2026-10-05 |
Max. vacuum · Sourced · 2 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 450 mbar | 450 mbar | 50 Hz · model 50 Hz; vacuum unspecified | Source · OEM_SOURCEΔp max (vacuum): 450Retrieved 2026-10-05 |
| 450 mbar | 450 mbar | 60 Hz · model 60 Hz; vacuum unspecified | Source · OEM_SOURCE different frequency Δp max (vacuum): 450Retrieved 2026-10-05 |
Operating-performance coverage
Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.
No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.
Document coverage
Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.
| Category | Model links | Family links | Public sources |
|---|---|---|---|
| Specifications | 1 | 0 |
|
| Performance curves / test data | 0 | 0 | Not collected |
| Operation / service manuals | 0 | 0 | Not collected |
| Parts documentation | 0 | 0 | Not collected |
| Drawings / dimensions | 0 | 0 | Not collected |
| Product / family literature | 1 | 0 |
|
| Other / unclassified | 0 | 0 | Not collected |