Data coverage & sources
The stored record for FPZ e10 TD: specifications, configurations, documents, sources, and gaps.
One model, connected records
FPZ → FPZ side channel blowers → e10 TD
Manufacturer model: e10 TD · OEM article / order number: Not collected · Equipment type: vacuum pump
Technology: Regenerative / Side Channel
Related applications: Material Handling, Pick + Place, Pneumatic Conveying, Vacuum Hold-Down
Related industries: Printing, Pulp + Paper, Woodworking + CNC
These are technology associations. Check the operating point and process requirements to establish suitability for this model.
Compare coverage across this familySpecifications and evidence
53 stored observations · 25 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.
The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.
Pumping speed · Sourced · 41 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 836 m³/h | 836 m3/h | 50 Hz · model 50 Hz; compression unspecified | Source · OEM_SOURCE different frequency Max. flow: 836Retrieved 2026-10-05 |
| 807 m³/h | 807 m3/h | 50 Hz · model 50 Hz; compression; at +50 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 807Retrieved 2026-10-05 |
| 779 m³/h | 779 m3/h | 50 Hz · model 50 Hz; compression; at +100 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 779Retrieved 2026-10-05 |
| 751 m³/h | 751 m3/h | 50 Hz · model 50 Hz; compression; at +150 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 751Retrieved 2026-10-05 |
| 724 m³/h | 724 m3/h | 50 Hz · model 50 Hz; compression; at +200 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 724Retrieved 2026-10-05 |
| 698 m³/h | 698 m3/h | 50 Hz · model 50 Hz; compression; at +250 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 698Retrieved 2026-10-05 |
| 672 m³/h | 672 m3/h | 50 Hz · model 50 Hz; compression; at +300 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 672Retrieved 2026-10-05 |
| 647 m³/h | 647 m3/h | 50 Hz · model 50 Hz; compression; at +350 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 647Retrieved 2026-10-05 |
| 622 m³/h | 622 m3/h | 50 Hz · model 50 Hz; compression; at +400 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 622Retrieved 2026-10-05 |
| 597 m³/h | 597 m3/h | 50 Hz · model 50 Hz; compression; at +450 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 597Retrieved 2026-10-05 |
| 573 m³/h | 573 m3/h | 50 Hz · model 50 Hz; compression; at +500 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 573Retrieved 2026-10-05 |
| 550 m³/h | 550 m3/h | 50 Hz · model 50 Hz; compression; at +550 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 550Retrieved 2026-10-05 |
| 836 m³/h | 836 m3/h | 50 Hz · model 50 Hz; vacuum unspecified | Source · OEM_SOURCE different frequency Max. flow: 836Retrieved 2026-10-05 |
| 806 m³/h | 806 m3/h | 50 Hz · model 50 Hz; vacuum; at -50 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 806Retrieved 2026-10-05 |
| 774 m³/h | 774 m3/h | 50 Hz · model 50 Hz; vacuum; at -100 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 774Retrieved 2026-10-05 |
| 738 m³/h | 738 m3/h | 50 Hz · model 50 Hz; vacuum; at -150 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 738Retrieved 2026-10-05 |
| 698 m³/h | 698 m3/h | 50 Hz · model 50 Hz; vacuum; at -200 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 698Retrieved 2026-10-05 |
| 653 m³/h | 653 m3/h | 50 Hz · model 50 Hz; vacuum; at -250 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 653Retrieved 2026-10-05 |
| 604 m³/h | 604 m3/h | 50 Hz · model 50 Hz; vacuum; at -300 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 604Retrieved 2026-10-05 |
| 551 m³/h | 551 m3/h | 50 Hz · model 50 Hz; vacuum; at -350 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 551Retrieved 2026-10-05 |
| 494 m³/h | 494 m3/h | 50 Hz · model 50 Hz; vacuum; at -400 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 494Retrieved 2026-10-05 |
| 433 m³/h | 433 m3/h | 50 Hz · model 50 Hz; vacuum; at -450 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 433Retrieved 2026-10-05 |
| 1009 m³/h | 1009 m3/h | 60 Hz · model 60 Hz; compression unspecified | Source · OEM_SOURCEMax. flow: 1009Retrieved 2026-10-05 |
| 984 m³/h | 984 m3/h | 60 Hz · model 60 Hz; compression; at +50 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 984Retrieved 2026-10-05 |
| 960 m³/h | 960 m3/h | 60 Hz · model 60 Hz; compression; at +100 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 960Retrieved 2026-10-05 |
| 936 m³/h | 936 m3/h | 60 Hz · model 60 Hz; compression; at +150 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 936Retrieved 2026-10-05 |
| 912 m³/h | 912 m3/h | 60 Hz · model 60 Hz; compression; at +200 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 912Retrieved 2026-10-05 |
| 888 m³/h | 888 m3/h | 60 Hz · model 60 Hz; compression; at +250 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 888Retrieved 2026-10-05 |
| 865 m³/h | 865 m3/h | 60 Hz · model 60 Hz; compression; at +300 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 865Retrieved 2026-10-05 |
| 843 m³/h | 843 m3/h | 60 Hz · model 60 Hz; compression; at +350 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 843Retrieved 2026-10-05 |
| 820 m³/h | 820 m3/h | 60 Hz · model 60 Hz; compression; at +400 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 820Retrieved 2026-10-05 |
| 1009 m³/h | 1009 m3/h | 60 Hz · model 60 Hz; vacuum unspecified | Source · OEM_SOURCEMax. flow: 1009Retrieved 2026-10-05 |
| 980 m³/h | 980 m3/h | 60 Hz · model 60 Hz; vacuum; at -50 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 980Retrieved 2026-10-05 |
| 951 m³/h | 951 m3/h | 60 Hz · model 60 Hz; vacuum; at -100 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 951Retrieved 2026-10-05 |
| 919 m³/h | 919 m3/h | 60 Hz · model 60 Hz; vacuum; at -150 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 919Retrieved 2026-10-05 |
| 883 m³/h | 883 m3/h | 60 Hz · model 60 Hz; vacuum; at -200 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 883Retrieved 2026-10-05 |
| 844 m³/h | 844 m3/h | 60 Hz · model 60 Hz; vacuum; at -250 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 844Retrieved 2026-10-05 |
| 802 m³/h | 802 m3/h | 60 Hz · model 60 Hz; vacuum; at -300 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 802Retrieved 2026-10-05 |
| 757 m³/h | 757 m3/h | 60 Hz · model 60 Hz; vacuum; at -350 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 757Retrieved 2026-10-05 |
| 709 m³/h | 709 m3/h | 60 Hz · model 60 Hz; vacuum; at -400 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 709Retrieved 2026-10-05 |
| 658 m³/h | 658 m3/h | 60 Hz · model 60 Hz; vacuum; at -450 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 658Retrieved 2026-10-05 |
Ultimate pressure · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Motor power · Sourced · 8 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 11.00 kW | 11 kW | 50 Hz · model 50 Hz; compression; at max. flow unspecified | Source · OEM_SOURCE different frequency Installed motor size: 11.00Retrieved 2026-10-05 |
| 18.50 kW | 18.5 kW | 50 Hz · model 50 Hz; compression; at Δp max 550 mbar unspecified | Source · OEM_SOURCE different frequency Installed motor size: 18.50Retrieved 2026-10-05 |
| 11.00 kW | 11 kW | 50 Hz · model 50 Hz; vacuum; at max. flow unspecified | Source · OEM_SOURCE different frequency Installed motor size: 11.00Retrieved 2026-10-05 |
| 15.00 kW | 15 kW | 50 Hz · model 50 Hz; vacuum; at Δp max 450 mbar unspecified | Source · OEM_SOURCE different frequency Installed motor size: 15.00Retrieved 2026-10-05 |
| 11.00 kW | 11 kW | 60 Hz · model 60 Hz; compression; at max. flow unspecified | Source · OEM_SOURCEInstalled motor size: 11.00Retrieved 2026-10-05 |
| 18.50 kW | 18.5 kW | 60 Hz · model 60 Hz; compression; at Δp max 400 mbar unspecified | Source · OEM_SOURCEInstalled motor size: 18.50Retrieved 2026-10-05 |
| 11.00 kW | 11 kW | 60 Hz · model 60 Hz; vacuum; at max. flow unspecified | Source · OEM_SOURCEInstalled motor size: 11.00Retrieved 2026-10-05 |
| 18.50 kW | 18.5 kW | 60 Hz · model 60 Hz; vacuum; at Δp max 450 mbar unspecified | Source · OEM_SOURCEInstalled motor size: 18.50Retrieved 2026-10-05 |
Speed · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Noise level · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Weight · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Dimensions · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Inlet connection · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Outlet connection · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Max. pressure · Sourced · 2 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 550 mbar | 550 mbar | 50 Hz · model 50 Hz; compression unspecified | Source · OEM_SOURCE different frequency Δp max (compression): 550Retrieved 2026-10-05 |
| 400 mbar | 400 mbar | 60 Hz · model 60 Hz; compression unspecified | Source · OEM_SOURCEΔp max (compression): 400Retrieved 2026-10-05 |
Max. vacuum · Sourced · 2 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 450 mbar | 450 mbar | 50 Hz · model 50 Hz; vacuum unspecified | Source · OEM_SOURCE different frequency Δp max (vacuum): 450Retrieved 2026-10-05 |
| 450 mbar | 450 mbar | 60 Hz · model 60 Hz; vacuum unspecified | Source · OEM_SOURCEΔp max (vacuum): 450Retrieved 2026-10-05 |
Operating-performance coverage
Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.
No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.
Document coverage
Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.
| Category | Model links | Family links | Public sources |
|---|---|---|---|
| Specifications | 1 | 0 |
|
| Performance curves / test data | 0 | 0 | Not collected |
| Operation / service manuals | 0 | 0 | Not collected |
| Parts documentation | 0 | 0 | Not collected |
| Drawings / dimensions | 0 | 0 | Not collected |
| Product / family literature | 1 | 0 |
|