Find equipmentComparePartsManufacturersTechnologiesIndustriesApplicationsAsset trackingMy equipmentTalk to a specialist

Data coverage & sources

The stored record for FPZ e10 TD: specifications, configurations, documents, sources, and gaps.

One model, connected records

FPZ → FPZ side channel blowers → e10 TD

Manufacturer model: e10 TD · OEM article / order number: Not collected · Equipment type: vacuum pump

Technology: Regenerative / Side Channel

Related applications: Material Handling, Pick + Place, Pneumatic Conveying, Vacuum Hold-Down
Related industries: Printing, Pulp + Paper, Woodworking + CNC

These are technology associations. Check the operating point and process requirements to establish suitability for this model.

Compare coverage across this family

Specifications and evidence

53 stored observations · 28 pass the source policy at 50 Hz. Individual ratings do not establish flow at a requested pressure.

The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.

Pumping speed · Sourced · 41 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
836 m³/h836 m3/h50 Hz · model
50 Hz; compression
unspecified
Source · OEM_SOURCE
Max. flow: 836
Retrieved 2026-10-05
807 m³/h807 m3/h50 Hz · model
50 Hz; compression; at +50 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 807
Retrieved 2026-10-05
779 m³/h779 m3/h50 Hz · model
50 Hz; compression; at +100 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 779
Retrieved 2026-10-05
751 m³/h751 m3/h50 Hz · model
50 Hz; compression; at +150 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 751
Retrieved 2026-10-05
724 m³/h724 m3/h50 Hz · model
50 Hz; compression; at +200 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 724
Retrieved 2026-10-05
698 m³/h698 m3/h50 Hz · model
50 Hz; compression; at +250 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 698
Retrieved 2026-10-05
672 m³/h672 m3/h50 Hz · model
50 Hz; compression; at +300 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 672
Retrieved 2026-10-05
647 m³/h647 m3/h50 Hz · model
50 Hz; compression; at +350 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 647
Retrieved 2026-10-05
622 m³/h622 m3/h50 Hz · model
50 Hz; compression; at +400 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 622
Retrieved 2026-10-05
597 m³/h597 m3/h50 Hz · model
50 Hz; compression; at +450 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 597
Retrieved 2026-10-05
573 m³/h573 m3/h50 Hz · model
50 Hz; compression; at +500 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 573
Retrieved 2026-10-05
550 m³/h550 m3/h50 Hz · model
50 Hz; compression; at +550 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 550
Retrieved 2026-10-05
836 m³/h836 m3/h50 Hz · model
50 Hz; vacuum
unspecified
Source · OEM_SOURCE
Max. flow: 836
Retrieved 2026-10-05
806 m³/h806 m3/h50 Hz · model
50 Hz; vacuum; at -50 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 806
Retrieved 2026-10-05
774 m³/h774 m3/h50 Hz · model
50 Hz; vacuum; at -100 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 774
Retrieved 2026-10-05
738 m³/h738 m3/h50 Hz · model
50 Hz; vacuum; at -150 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 738
Retrieved 2026-10-05
698 m³/h698 m3/h50 Hz · model
50 Hz; vacuum; at -200 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 698
Retrieved 2026-10-05
653 m³/h653 m3/h50 Hz · model
50 Hz; vacuum; at -250 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 653
Retrieved 2026-10-05
604 m³/h604 m3/h50 Hz · model
50 Hz; vacuum; at -300 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 604
Retrieved 2026-10-05
551 m³/h551 m3/h50 Hz · model
50 Hz; vacuum; at -350 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 551
Retrieved 2026-10-05
494 m³/h494 m3/h50 Hz · model
50 Hz; vacuum; at -400 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 494
Retrieved 2026-10-05
433 m³/h433 m3/h50 Hz · model
50 Hz; vacuum; at -450 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 433
Retrieved 2026-10-05
1009 m³/h1009 m3/h60 Hz · model
60 Hz; compression
unspecified
Source · OEM_SOURCE
different frequency
Max. flow: 1009
Retrieved 2026-10-05
984 m³/h984 m3/h60 Hz · model
60 Hz; compression; at +50 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 984
Retrieved 2026-10-05
960 m³/h960 m3/h60 Hz · model
60 Hz; compression; at +100 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 960
Retrieved 2026-10-05
936 m³/h936 m3/h60 Hz · model
60 Hz; compression; at +150 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 936
Retrieved 2026-10-05
912 m³/h912 m3/h60 Hz · model
60 Hz; compression; at +200 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 912
Retrieved 2026-10-05
888 m³/h888 m3/h60 Hz · model
60 Hz; compression; at +250 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 888
Retrieved 2026-10-05
865 m³/h865 m3/h60 Hz · model
60 Hz; compression; at +300 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 865
Retrieved 2026-10-05
843 m³/h843 m3/h60 Hz · model
60 Hz; compression; at +350 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 843
Retrieved 2026-10-05
820 m³/h820 m3/h60 Hz · model
60 Hz; compression; at +400 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 820
Retrieved 2026-10-05
1009 m³/h1009 m3/h60 Hz · model
60 Hz; vacuum
unspecified
Source · OEM_SOURCE
different frequency
Max. flow: 1009
Retrieved 2026-10-05
980 m³/h980 m3/h60 Hz · model
60 Hz; vacuum; at -50 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 980
Retrieved 2026-10-05
951 m³/h951 m3/h60 Hz · model
60 Hz; vacuum; at -100 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 951
Retrieved 2026-10-05
919 m³/h919 m3/h60 Hz · model
60 Hz; vacuum; at -150 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 919
Retrieved 2026-10-05
883 m³/h883 m3/h60 Hz · model
60 Hz; vacuum; at -200 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 883
Retrieved 2026-10-05
844 m³/h844 m3/h60 Hz · model
60 Hz; vacuum; at -250 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 844
Retrieved 2026-10-05
802 m³/h802 m3/h60 Hz · model
60 Hz; vacuum; at -300 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 802
Retrieved 2026-10-05
757 m³/h757 m3/h60 Hz · model
60 Hz; vacuum; at -350 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 757
Retrieved 2026-10-05
709 m³/h709 m3/h60 Hz · model
60 Hz; vacuum; at -400 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 709
Retrieved 2026-10-05
658 m³/h658 m3/h60 Hz · model
60 Hz; vacuum; at -450 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 658
Retrieved 2026-10-05
Ultimate pressure · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Motor power · Sourced · 8 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
11.00 kW11 kW50 Hz · model
50 Hz; compression; at max. flow
unspecified
Source · OEM_SOURCE
Installed motor size: 11.00
Retrieved 2026-10-05
18.50 kW18.5 kW50 Hz · model
50 Hz; compression; at Δp max 550 mbar
unspecified
Source · OEM_SOURCE
Installed motor size: 18.50
Retrieved 2026-10-05
11.00 kW11 kW50 Hz · model
50 Hz; vacuum; at max. flow
unspecified
Source · OEM_SOURCE
Installed motor size: 11.00
Retrieved 2026-10-05
15.00 kW15 kW50 Hz · model
50 Hz; vacuum; at Δp max 450 mbar
unspecified
Source · OEM_SOURCE
Installed motor size: 15.00
Retrieved 2026-10-05
11.00 kW11 kW60 Hz · model
60 Hz; compression; at max. flow
unspecified
Source · OEM_SOURCE
different frequency
Installed motor size: 11.00
Retrieved 2026-10-05
18.50 kW18.5 kW60 Hz · model
60 Hz; compression; at Δp max 400 mbar
unspecified
Source · OEM_SOURCE
different frequency
Installed motor size: 18.50
Retrieved 2026-10-05
11.00 kW11 kW60 Hz · model
60 Hz; vacuum; at max. flow
unspecified
Source · OEM_SOURCE
different frequency
Installed motor size: 11.00
Retrieved 2026-10-05
18.50 kW18.5 kW60 Hz · model
60 Hz; vacuum; at Δp max 450 mbar
unspecified
Source · OEM_SOURCE
different frequency
Installed motor size: 18.50
Retrieved 2026-10-05
Speed · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Noise level · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Weight · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Dimensions · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Inlet connection · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Outlet connection · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Max. pressure · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
550 mbar550 mbar50 Hz · model
50 Hz; compression
unspecified
Source · OEM_SOURCE
Δp max (compression): 550
Retrieved 2026-10-05
400 mbar400 mbar60 Hz · model
60 Hz; compression
unspecified
Source · OEM_SOURCE
different frequency
Δp max (compression): 400
Retrieved 2026-10-05
Max. vacuum · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
450 mbar450 mbar50 Hz · model
50 Hz; vacuum
unspecified
Source · OEM_SOURCE
Δp max (vacuum): 450
Retrieved 2026-10-05
450 mbar450 mbar60 Hz · model
60 Hz; vacuum
unspecified
Source · OEM_SOURCE
different frequency
Δp max (vacuum): 450
Retrieved 2026-10-05

Operating-performance coverage

Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.

No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.

Document coverage

Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.

CategoryModel linksFamily linksPublic sources
Specifications10
Performance curves / test data00Not collected
Operation / service manuals00Not collected
Parts documentation00Not collected
Drawings / dimensions00Not collected
Product / family literature10
Other / unclassified00Not collected