Find equipmentComparePartsManufacturersTechnologiesIndustriesApplicationsAsset trackingMy equipmentTalk to a specialist

Data coverage & sources

The stored record for FPZ e11 TD: specifications, configurations, documents, sources, and gaps.

One model, connected records

FPZ → FPZ side channel blowers → e11 TD

Manufacturer model: e11 TD · OEM article / order number: Not collected · Equipment type: vacuum pump

Technology: Regenerative / Side Channel

Related applications: Material Handling, Pick + Place, Pneumatic Conveying, Vacuum Hold-Down
Related industries: Printing, Pulp + Paper, Woodworking + CNC

These are technology associations. Check the operating point and process requirements to establish suitability for this model.

Compare coverage across this family

Specifications and evidence

47 stored observations · 25 pass the source policy at 50 Hz. Individual ratings do not establish flow at a requested pressure.

The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.

Pumping speed · Sourced · 35 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
969 m³/h969 m3/h50 Hz · model
50 Hz; compression
unspecified
Source · OEM_SOURCE
Max. flow: 969
Retrieved 2026-10-05
941 m³/h941 m3/h50 Hz · model
50 Hz; compression; at +50 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 941
Retrieved 2026-10-05
915 m³/h915 m3/h50 Hz · model
50 Hz; compression; at +100 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 915
Retrieved 2026-10-05
891 m³/h891 m3/h50 Hz · model
50 Hz; compression; at +150 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 891
Retrieved 2026-10-05
867 m³/h867 m3/h50 Hz · model
50 Hz; compression; at +200 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 867
Retrieved 2026-10-05
844 m³/h844 m3/h50 Hz · model
50 Hz; compression; at +250 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 844
Retrieved 2026-10-05
823 m³/h823 m3/h50 Hz · model
50 Hz; compression; at +300 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 823
Retrieved 2026-10-05
803 m³/h803 m3/h50 Hz · model
50 Hz; compression; at +350 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 803
Retrieved 2026-10-05
784 m³/h784 m3/h50 Hz · model
50 Hz; compression; at +400 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 784
Retrieved 2026-10-05
767 m³/h767 m3/h50 Hz · model
50 Hz; compression; at +450 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 767
Retrieved 2026-10-05
969 m³/h969 m3/h50 Hz · model
50 Hz; vacuum
unspecified
Source · OEM_SOURCE
Max. flow: 969
Retrieved 2026-10-05
938 m³/h938 m3/h50 Hz · model
50 Hz; vacuum; at -50 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 938
Retrieved 2026-10-05
911 m³/h911 m3/h50 Hz · model
50 Hz; vacuum; at -100 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 911
Retrieved 2026-10-05
881 m³/h881 m3/h50 Hz · model
50 Hz; vacuum; at -150 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 881
Retrieved 2026-10-05
850 m³/h850 m3/h50 Hz · model
50 Hz; vacuum; at -200 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 850
Retrieved 2026-10-05
817 m³/h817 m3/h50 Hz · model
50 Hz; vacuum; at -250 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 817
Retrieved 2026-10-05
782 m³/h782 m3/h50 Hz · model
50 Hz; vacuum; at -300 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 782
Retrieved 2026-10-05
745 m³/h745 m3/h50 Hz · model
50 Hz; vacuum; at -350 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 745
Retrieved 2026-10-05
706 m³/h706 m3/h50 Hz · model
50 Hz; vacuum; at -400 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 706
Retrieved 2026-10-05
1169 m³/h1169 m3/h60 Hz · model
60 Hz; compression
unspecified
Source · OEM_SOURCE
different frequency
Max. flow: 1169
Retrieved 2026-10-05
1146 m³/h1146 m3/h60 Hz · model
60 Hz; compression; at +50 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 1146
Retrieved 2026-10-05
1123 m³/h1123 m3/h60 Hz · model
60 Hz; compression; at +100 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 1123
Retrieved 2026-10-05
1101 m³/h1101 m3/h60 Hz · model
60 Hz; compression; at +150 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 1101
Retrieved 2026-10-05
1079 m³/h1079 m3/h60 Hz · model
60 Hz; compression; at +200 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 1079
Retrieved 2026-10-05
1059 m³/h1059 m3/h60 Hz · model
60 Hz; compression; at +250 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 1059
Retrieved 2026-10-05
1039 m³/h1039 m3/h60 Hz · model
60 Hz; compression; at +300 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 1039
Retrieved 2026-10-05
1169 m³/h1169 m3/h60 Hz · model
60 Hz; vacuum
unspecified
Source · OEM_SOURCE
different frequency
Max. flow: 1169
Retrieved 2026-10-05
1139 m³/h1139 m3/h60 Hz · model
60 Hz; vacuum; at -50 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 1139
Retrieved 2026-10-05
1113 m³/h1113 m3/h60 Hz · model
60 Hz; vacuum; at -100 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 1113
Retrieved 2026-10-05
1086 m³/h1086 m3/h60 Hz · model
60 Hz; vacuum; at -150 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 1086
Retrieved 2026-10-05
1058 m³/h1058 m3/h60 Hz · model
60 Hz; vacuum; at -200 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 1058
Retrieved 2026-10-05
1028 m³/h1028 m3/h60 Hz · model
60 Hz; vacuum; at -250 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 1028
Retrieved 2026-10-05
996 m³/h996 m3/h60 Hz · model
60 Hz; vacuum; at -300 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 996
Retrieved 2026-10-05
964 m³/h964 m3/h60 Hz · model
60 Hz; vacuum; at -350 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 964
Retrieved 2026-10-05
929 m³/h929 m3/h60 Hz · model
60 Hz; vacuum; at -400 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 929
Retrieved 2026-10-05
Ultimate pressure · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Motor power · Sourced · 8 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
15.00 kW15 kW50 Hz · model
50 Hz; compression; at max. flow
unspecified
Source · OEM_SOURCE
Installed motor size: 15.00
Retrieved 2026-10-05
18.50 kW18.5 kW50 Hz · model
50 Hz; compression; at Δp max 450 mbar
unspecified
Source · OEM_SOURCE
Installed motor size: 18.50
Retrieved 2026-10-05
15.00 kW15 kW50 Hz · model
50 Hz; vacuum; at max. flow
unspecified
Source · OEM_SOURCE
Installed motor size: 15.00
Retrieved 2026-10-05
15.00 kW15 kW50 Hz · model
50 Hz; vacuum; at Δp max 400 mbar
unspecified
Source · OEM_SOURCE
Installed motor size: 15.00
Retrieved 2026-10-05
15.00 kW15 kW60 Hz · model
60 Hz; compression; at max. flow
unspecified
Source · OEM_SOURCE
different frequency
Installed motor size: 15.00
Retrieved 2026-10-05
18.50 kW18.5 kW60 Hz · model
60 Hz; compression; at Δp max 300 mbar
unspecified
Source · OEM_SOURCE
different frequency
Installed motor size: 18.50
Retrieved 2026-10-05
15.00 kW15 kW60 Hz · model
60 Hz; vacuum; at max. flow
unspecified
Source · OEM_SOURCE
different frequency
Installed motor size: 15.00
Retrieved 2026-10-05
18.50 kW18.5 kW60 Hz · model
60 Hz; vacuum; at Δp max 400 mbar
unspecified
Source · OEM_SOURCE
different frequency
Installed motor size: 18.50
Retrieved 2026-10-05
Speed · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Noise level · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Weight · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Dimensions · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Inlet connection · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Outlet connection · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Max. pressure · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
450 mbar450 mbar50 Hz · model
50 Hz; compression
unspecified
Source · OEM_SOURCE
Δp max (compression): 450
Retrieved 2026-10-05
300 mbar300 mbar60 Hz · model
60 Hz; compression
unspecified
Source · OEM_SOURCE
different frequency
Δp max (compression): 300
Retrieved 2026-10-05
Max. vacuum · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
400 mbar400 mbar50 Hz · model
50 Hz; vacuum
unspecified
Source · OEM_SOURCE
Δp max (vacuum): 400
Retrieved 2026-10-05
400 mbar400 mbar60 Hz · model
60 Hz; vacuum
unspecified
Source · OEM_SOURCE
different frequency
Δp max (vacuum): 400
Retrieved 2026-10-05

Operating-performance coverage

Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.

No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.

Document coverage

Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.

CategoryModel linksFamily linksPublic sources
Specifications10
Performance curves / test data00Not collected
Operation / service manuals00Not collected
Parts documentation00Not collected
Drawings / dimensions00Not collected
Product / family literature10
Other / unclassified00Not collected