Find equipmentComparePartsManufacturersTechnologiesIndustriesApplicationsAsset trackingMy equipmentTalk to a specialist

Data coverage & sources

The stored record for FPZ e12 MS: specifications, configurations, documents, sources, and gaps.

One model, connected records

FPZ → FPZ side channel blowers → e12 MS

Manufacturer model: e12 MS · OEM article / order number: Not collected · Equipment type: vacuum pump

Technology: Regenerative / Side Channel

Related applications: Material Handling, Pick + Place, Pneumatic Conveying, Vacuum Hold-Down
Related industries: Printing, Pulp + Paper, Woodworking + CNC

These are technology associations. Check the operating point and process requirements to establish suitability for this model.

Compare coverage across this family

Specifications and evidence

43 stored observations · 20 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.

The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.

Pumping speed · Sourced · 31 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
1024 m³/h1024 m3/h50 Hz · model
50 Hz; compression
unspecified
Source · OEM_SOURCE
different frequency
Max. flow: 1024
Retrieved 2026-10-05
959 m³/h959 m3/h50 Hz · model
50 Hz; compression; at +50 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 959
Retrieved 2026-10-05
906 m³/h906 m3/h50 Hz · model
50 Hz; compression; at +100 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 906
Retrieved 2026-10-05
854 m³/h854 m3/h50 Hz · model
50 Hz; compression; at +150 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 854
Retrieved 2026-10-05
801 m³/h801 m3/h50 Hz · model
50 Hz; compression; at +200 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 801
Retrieved 2026-10-05
749 m³/h749 m3/h50 Hz · model
50 Hz; compression; at +250 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 749
Retrieved 2026-10-05
697 m³/h697 m3/h50 Hz · model
50 Hz; compression; at +300 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 697
Retrieved 2026-10-05
645 m³/h645 m3/h50 Hz · model
50 Hz; compression; at +350 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 645
Retrieved 2026-10-05
593 m³/h593 m3/h50 Hz · model
50 Hz; compression; at +400 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 593
Retrieved 2026-10-05
542 m³/h542 m3/h50 Hz · model
50 Hz; compression; at +450 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 542
Retrieved 2026-10-05
1012 m³/h1012 m3/h50 Hz · model
50 Hz; vacuum
unspecified
Source · OEM_SOURCE
different frequency
Max. flow: 1012
Retrieved 2026-10-05
959 m³/h959 m3/h50 Hz · model
50 Hz; vacuum; at -50 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 959
Retrieved 2026-10-05
900 m³/h900 m3/h50 Hz · model
50 Hz; vacuum; at -100 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 900
Retrieved 2026-10-05
833 m³/h833 m3/h50 Hz · model
50 Hz; vacuum; at -150 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 833
Retrieved 2026-10-05
757 m³/h757 m3/h50 Hz · model
50 Hz; vacuum; at -200 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 757
Retrieved 2026-10-05
672 m³/h672 m3/h50 Hz · model
50 Hz; vacuum; at -250 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 672
Retrieved 2026-10-05
579 m³/h579 m3/h50 Hz · model
50 Hz; vacuum; at -300 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 579
Retrieved 2026-10-05
1221 m³/h1221 m3/h60 Hz · model
60 Hz; compression
unspecified
Source · OEM_SOURCE
Max. flow: 1221
Retrieved 2026-10-05
1175 m³/h1175 m3/h60 Hz · model
60 Hz; compression; at +50 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 1175
Retrieved 2026-10-05
1130 m³/h1130 m3/h60 Hz · model
60 Hz; compression; at +100 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 1130
Retrieved 2026-10-05
1085 m³/h1085 m3/h60 Hz · model
60 Hz; compression; at +150 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 1085
Retrieved 2026-10-05
1040 m³/h1040 m3/h60 Hz · model
60 Hz; compression; at +200 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 1040
Retrieved 2026-10-05
995 m³/h995 m3/h60 Hz · model
60 Hz; compression; at +250 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 995
Retrieved 2026-10-05
950 m³/h950 m3/h60 Hz · model
60 Hz; compression; at +300 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 950
Retrieved 2026-10-05
1221 m³/h1221 m3/h60 Hz · model
60 Hz; vacuum
unspecified
Source · OEM_SOURCE
Max. flow: 1221
Retrieved 2026-10-05
1171 m³/h1171 m3/h60 Hz · model
60 Hz; vacuum; at -50 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 1171
Retrieved 2026-10-05
1117 m³/h1117 m3/h60 Hz · model
60 Hz; vacuum; at -100 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 1117
Retrieved 2026-10-05
1057 m³/h1057 m3/h60 Hz · model
60 Hz; vacuum; at -150 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 1057
Retrieved 2026-10-05
991 m³/h991 m3/h60 Hz · model
60 Hz; vacuum; at -200 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 991
Retrieved 2026-10-05
918 m³/h918 m3/h60 Hz · model
60 Hz; vacuum; at -250 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 918
Retrieved 2026-10-05
838 m³/h838 m3/h60 Hz · model
60 Hz; vacuum; at -300 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 838
Retrieved 2026-10-05
Ultimate pressure · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Motor power · Sourced · 8 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
9.20 kW9.2 kW50 Hz · model
50 Hz; compression; at max. flow
unspecified
Source · OEM_SOURCE
different frequency
Installed motor size: 9.20
Retrieved 2026-10-05
18.50 kW18.5 kW50 Hz · model
50 Hz; compression; at Δp max 450 mbar
unspecified
Source · OEM_SOURCE
different frequency
Installed motor size: 18.50
Retrieved 2026-10-05
9.20 kW9.2 kW50 Hz · model
50 Hz; vacuum; at max. flow
unspecified
Source · OEM_SOURCE
different frequency
Installed motor size: 9.20
Retrieved 2026-10-05
15.00 kW15 kW50 Hz · model
50 Hz; vacuum; at Δp max 325 mbar
unspecified
Source · OEM_SOURCE
different frequency
Installed motor size: 15.00
Retrieved 2026-10-05
9.20 kW9.2 kW60 Hz · model
60 Hz; compression; at max. flow
unspecified
Source · OEM_SOURCE
Installed motor size: 9.20
Retrieved 2026-10-05
18.50 kW18.5 kW60 Hz · model
60 Hz; compression; at Δp max 325 mbar
unspecified
Source · OEM_SOURCE
Installed motor size: 18.50
Retrieved 2026-10-05
9.20 kW9.2 kW60 Hz · model
60 Hz; vacuum; at max. flow
unspecified
Source · OEM_SOURCE
Installed motor size: 9.20
Retrieved 2026-10-05
18.50 kW18.5 kW60 Hz · model
60 Hz; vacuum; at Δp max 325 mbar
unspecified
Source · OEM_SOURCE
Installed motor size: 18.50
Retrieved 2026-10-05
Speed · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Noise level · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Weight · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Dimensions · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Inlet connection · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Outlet connection · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Max. pressure · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
450 mbar450 mbar50 Hz · model
50 Hz; compression
unspecified
Source · OEM_SOURCE
different frequency
Δp max (compression): 450
Retrieved 2026-10-05
325 mbar325 mbar60 Hz · model
60 Hz; compression
unspecified
Source · OEM_SOURCE
Δp max (compression): 325
Retrieved 2026-10-05
Max. vacuum · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
325 mbar325 mbar50 Hz · model
50 Hz; vacuum
unspecified
Source · OEM_SOURCE
different frequency
Δp max (vacuum): 325
Retrieved 2026-10-05
325 mbar325 mbar60 Hz · model
60 Hz; vacuum
unspecified
Source · OEM_SOURCE
Δp max (vacuum): 325
Retrieved 2026-10-05

Operating-performance coverage

Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.

No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.

Document coverage

Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.

CategoryModel linksFamily linksPublic sources
Specifications10
Performance curves / test data00Not collected
Operation / service manuals00Not collected
Parts documentation00Not collected
Drawings / dimensions00Not collected
Product / family literature10
Other / unclassified00Not collected