Data coverage & sources
The stored record for FPZ e12 MS: specifications, configurations, documents, sources, and gaps.
One model, connected records
FPZ → FPZ side channel blowers → e12 MS
Manufacturer model: e12 MS · OEM article / order number: Not collected · Equipment type: vacuum pump
Technology: Regenerative / Side Channel
Related applications: Material Handling, Pick + Place, Pneumatic Conveying, Vacuum Hold-Down
Related industries: Printing, Pulp + Paper, Woodworking + CNC
These are technology associations. Check the operating point and process requirements to establish suitability for this model.
Compare coverage across this familySpecifications and evidence
43 stored observations · 23 pass the source policy at 50 Hz. Individual ratings do not establish flow at a requested pressure.
The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.
Pumping speed · Sourced · 31 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 1024 m³/h | 1024 m3/h | 50 Hz · model 50 Hz; compression unspecified | Source · OEM_SOURCEMax. flow: 1024Retrieved 2026-10-05 |
| 959 m³/h | 959 m3/h | 50 Hz · model 50 Hz; compression; at +50 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 959Retrieved 2026-10-05 |
| 906 m³/h | 906 m3/h | 50 Hz · model 50 Hz; compression; at +100 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 906Retrieved 2026-10-05 |
| 854 m³/h | 854 m3/h | 50 Hz · model 50 Hz; compression; at +150 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 854Retrieved 2026-10-05 |
| 801 m³/h | 801 m3/h | 50 Hz · model 50 Hz; compression; at +200 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 801Retrieved 2026-10-05 |
| 749 m³/h | 749 m3/h | 50 Hz · model 50 Hz; compression; at +250 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 749Retrieved 2026-10-05 |
| 697 m³/h | 697 m3/h | 50 Hz · model 50 Hz; compression; at +300 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 697Retrieved 2026-10-05 |
| 645 m³/h | 645 m3/h | 50 Hz · model 50 Hz; compression; at +350 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 645Retrieved 2026-10-05 |
| 593 m³/h | 593 m3/h | 50 Hz · model 50 Hz; compression; at +400 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 593Retrieved 2026-10-05 |
| 542 m³/h | 542 m3/h | 50 Hz · model 50 Hz; compression; at +450 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 542Retrieved 2026-10-05 |
| 1012 m³/h | 1012 m3/h | 50 Hz · model 50 Hz; vacuum unspecified | Source · OEM_SOURCEMax. flow: 1012Retrieved 2026-10-05 |
| 959 m³/h | 959 m3/h | 50 Hz · model 50 Hz; vacuum; at -50 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 959Retrieved 2026-10-05 |
| 900 m³/h | 900 m3/h | 50 Hz · model 50 Hz; vacuum; at -100 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 900Retrieved 2026-10-05 |
| 833 m³/h | 833 m3/h | 50 Hz · model 50 Hz; vacuum; at -150 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 833Retrieved 2026-10-05 |
| 757 m³/h | 757 m3/h | 50 Hz · model 50 Hz; vacuum; at -200 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 757Retrieved 2026-10-05 |
| 672 m³/h | 672 m3/h | 50 Hz · model 50 Hz; vacuum; at -250 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 672Retrieved 2026-10-05 |
| 579 m³/h | 579 m3/h | 50 Hz · model 50 Hz; vacuum; at -300 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 579Retrieved 2026-10-05 |
| 1221 m³/h | 1221 m3/h | 60 Hz · model 60 Hz; compression unspecified | Source · OEM_SOURCE different frequency Max. flow: 1221Retrieved 2026-10-05 |
| 1175 m³/h | 1175 m3/h | 60 Hz · model 60 Hz; compression; at +50 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 1175Retrieved 2026-10-05 |
| 1130 m³/h | 1130 m3/h | 60 Hz · model 60 Hz; compression; at +100 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 1130Retrieved 2026-10-05 |
| 1085 m³/h | 1085 m3/h | 60 Hz · model 60 Hz; compression; at +150 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 1085Retrieved 2026-10-05 |
| 1040 m³/h | 1040 m3/h | 60 Hz · model 60 Hz; compression; at +200 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 1040Retrieved 2026-10-05 |
| 995 m³/h | 995 m3/h | 60 Hz · model 60 Hz; compression; at +250 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 995Retrieved 2026-10-05 |
| 950 m³/h | 950 m3/h | 60 Hz · model 60 Hz; compression; at +300 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 950Retrieved 2026-10-05 |
| 1221 m³/h | 1221 m3/h | 60 Hz · model 60 Hz; vacuum unspecified | Source · OEM_SOURCE different frequency Max. flow: 1221Retrieved 2026-10-05 |
| 1171 m³/h | 1171 m3/h | 60 Hz · model 60 Hz; vacuum; at -50 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 1171Retrieved 2026-10-05 |
| 1117 m³/h | 1117 m3/h | 60 Hz · model 60 Hz; vacuum; at -100 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 1117Retrieved 2026-10-05 |
| 1057 m³/h | 1057 m3/h | 60 Hz · model 60 Hz; vacuum; at -150 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 1057Retrieved 2026-10-05 |
| 991 m³/h | 991 m3/h | 60 Hz · model 60 Hz; vacuum; at -200 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 991Retrieved 2026-10-05 |
| 918 m³/h | 918 m3/h | 60 Hz · model 60 Hz; vacuum; at -250 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 918Retrieved 2026-10-05 |
| 838 m³/h | 838 m3/h | 60 Hz · model 60 Hz; vacuum; at -300 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 838Retrieved 2026-10-05 |
Ultimate pressure · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Motor power · Sourced · 8 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 9.20 kW | 9.2 kW | 50 Hz · model 50 Hz; compression; at max. flow unspecified | Source · OEM_SOURCEInstalled motor size: 9.20Retrieved 2026-10-05 |
| 18.50 kW | 18.5 kW | 50 Hz · model 50 Hz; compression; at Δp max 450 mbar unspecified | Source · OEM_SOURCEInstalled motor size: 18.50Retrieved 2026-10-05 |
| 9.20 kW | 9.2 kW | 50 Hz · model 50 Hz; vacuum; at max. flow unspecified | Source · OEM_SOURCEInstalled motor size: 9.20Retrieved 2026-10-05 |
| 15.00 kW | 15 kW | 50 Hz · model 50 Hz; vacuum; at Δp max 325 mbar unspecified | Source · OEM_SOURCEInstalled motor size: 15.00Retrieved 2026-10-05 |
| 9.20 kW | 9.2 kW | 60 Hz · model 60 Hz; compression; at max. flow unspecified | Source · OEM_SOURCE different frequency Installed motor size: 9.20Retrieved 2026-10-05 |
| 18.50 kW | 18.5 kW | 60 Hz · model 60 Hz; compression; at Δp max 325 mbar unspecified | Source · OEM_SOURCE different frequency Installed motor size: 18.50Retrieved 2026-10-05 |
| 9.20 kW | 9.2 kW | 60 Hz · model 60 Hz; vacuum; at max. flow unspecified | Source · OEM_SOURCE different frequency Installed motor size: 9.20Retrieved 2026-10-05 |
| 18.50 kW | 18.5 kW | 60 Hz · model 60 Hz; vacuum; at Δp max 325 mbar unspecified | Source · OEM_SOURCE different frequency Installed motor size: 18.50Retrieved 2026-10-05 |
Speed · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Noise level · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Weight · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Dimensions · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Inlet connection · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Outlet connection · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Max. pressure · Sourced · 2 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 450 mbar | 450 mbar | 50 Hz · model 50 Hz; compression unspecified | Source · OEM_SOURCEΔp max (compression): 450Retrieved 2026-10-05 |
| 325 mbar | 325 mbar | 60 Hz · model 60 Hz; compression unspecified | Source · OEM_SOURCE different frequency Δp max (compression): 325Retrieved 2026-10-05 |
Max. vacuum · Sourced · 2 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 325 mbar | 325 mbar | 50 Hz · model 50 Hz; vacuum unspecified | Source · OEM_SOURCEΔp max (vacuum): 325Retrieved 2026-10-05 |
| 325 mbar | 325 mbar | 60 Hz · model 60 Hz; vacuum unspecified | Source · OEM_SOURCE different frequency Δp max (vacuum): 325Retrieved 2026-10-05 |
Operating-performance coverage
Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.
No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.
Document coverage
Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.
| Category | Model links | Family links | Public sources |
|---|---|---|---|
| Specifications | 1 | 0 |
|
| Performance curves / test data | 0 | 0 | Not collected |
| Operation / service manuals | 0 | 0 | Not collected |
| Parts documentation | 0 | 0 | Not collected |
| Drawings / dimensions | 0 | 0 | Not collected |
| Product / family literature | 1 | 0 |
|
| Other / unclassified | 0 | 0 | Not collected |