Data coverage & sources
The stored record for FPZ e12 TD: specifications, configurations, documents, sources, and gaps.
One model, connected records
FPZ → FPZ side channel blowers → e12 TD
Manufacturer model: e12 TD · OEM article / order number: Not collected · Equipment type: vacuum pump
Technology: Regenerative / Side Channel
Related applications: Material Handling, Pick + Place, Pneumatic Conveying, Vacuum Hold-Down
Related industries: Printing, Pulp + Paper, Woodworking + CNC
These are technology associations. Check the operating point and process requirements to establish suitability for this model.
Compare coverage across this familySpecifications and evidence
48 stored observations · 23 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.
The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.
Pumping speed · Sourced · 36 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 1046 m³/h | 1046 m3/h | 50 Hz · model 50 Hz; compression unspecified | Source · OEM_SOURCE different frequency Max. flow: 1046Retrieved 2026-10-05 |
| 1017 m³/h | 1017 m3/h | 50 Hz · model 50 Hz; compression; at +50 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 1017Retrieved 2026-10-05 |
| 987 m³/h | 987 m3/h | 50 Hz · model 50 Hz; compression; at +100 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 987Retrieved 2026-10-05 |
| 958 m³/h | 958 m3/h | 50 Hz · model 50 Hz; compression; at +150 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 958Retrieved 2026-10-05 |
| 929 m³/h | 929 m3/h | 50 Hz · model 50 Hz; compression; at +200 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 929Retrieved 2026-10-05 |
| 900 m³/h | 900 m3/h | 50 Hz · model 50 Hz; compression; at +250 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 900Retrieved 2026-10-05 |
| 872 m³/h | 872 m3/h | 50 Hz · model 50 Hz; compression; at +300 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 872Retrieved 2026-10-05 |
| 844 m³/h | 844 m3/h | 50 Hz · model 50 Hz; compression; at +350 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 844Retrieved 2026-10-05 |
| 816 m³/h | 816 m3/h | 50 Hz · model 50 Hz; compression; at +400 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 816Retrieved 2026-10-05 |
| 789 m³/h | 789 m3/h | 50 Hz · model 50 Hz; compression; at +450 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 789Retrieved 2026-10-05 |
| 1046 m³/h | 1046 m3/h | 50 Hz · model 50 Hz; vacuum unspecified | Source · OEM_SOURCE different frequency Max. flow: 1046Retrieved 2026-10-05 |
| 1024 m³/h | 1024 m3/h | 50 Hz · model 50 Hz; vacuum; at -50 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 1024Retrieved 2026-10-05 |
| 991 m³/h | 991 m3/h | 50 Hz · model 50 Hz; vacuum; at -100 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 991Retrieved 2026-10-05 |
| 953 m³/h | 953 m3/h | 50 Hz · model 50 Hz; vacuum; at -150 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 953Retrieved 2026-10-05 |
| 910 m³/h | 910 m3/h | 50 Hz · model 50 Hz; vacuum; at -200 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 910Retrieved 2026-10-05 |
| 862 m³/h | 862 m3/h | 50 Hz · model 50 Hz; vacuum; at -250 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 862Retrieved 2026-10-05 |
| 808 m³/h | 808 m3/h | 50 Hz · model 50 Hz; vacuum; at -300 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 808Retrieved 2026-10-05 |
| 750 m³/h | 750 m3/h | 50 Hz · model 50 Hz; vacuum; at -350 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 750Retrieved 2026-10-05 |
| 687 m³/h | 687 m3/h | 50 Hz · model 50 Hz; vacuum; at -400 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 687Retrieved 2026-10-05 |
| 1263 m³/h | 1263 m3/h | 60 Hz · model 60 Hz; compression unspecified | Source · OEM_SOURCEMax. flow: 1263Retrieved 2026-10-05 |
| 1237 m³/h | 1237 m3/h | 60 Hz · model 60 Hz; compression; at +50 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 1237Retrieved 2026-10-05 |
| 1212 m³/h | 1212 m3/h | 60 Hz · model 60 Hz; compression; at +100 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 1212Retrieved 2026-10-05 |
| 1186 m³/h | 1186 m3/h | 60 Hz · model 60 Hz; compression; at +150 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 1186Retrieved 2026-10-05 |
| 1161 m³/h | 1161 m3/h | 60 Hz · model 60 Hz; compression; at +200 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 1161Retrieved 2026-10-05 |
| 1136 m³/h | 1136 m3/h | 60 Hz · model 60 Hz; compression; at +250 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 1136Retrieved 2026-10-05 |
| 1112 m³/h | 1112 m3/h | 60 Hz · model 60 Hz; compression; at +300 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 1112Retrieved 2026-10-05 |
| 1087 m³/h | 1087 m3/h | 60 Hz · model 60 Hz; compression; at +350 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 1087Retrieved 2026-10-05 |
| 1263 m³/h | 1263 m3/h | 60 Hz · model 60 Hz; vacuum unspecified | Source · OEM_SOURCEMax. flow: 1263Retrieved 2026-10-05 |
| 1244 m³/h | 1244 m3/h | 60 Hz · model 60 Hz; vacuum; at -50 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 1244Retrieved 2026-10-05 |
| 1214 m³/h | 1214 m3/h | 60 Hz · model 60 Hz; vacuum; at -100 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 1214Retrieved 2026-10-05 |
| 1180 m³/h | 1180 m3/h | 60 Hz · model 60 Hz; vacuum; at -150 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 1180Retrieved 2026-10-05 |
| 1142 m³/h | 1142 m3/h | 60 Hz · model 60 Hz; vacuum; at -200 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 1142Retrieved 2026-10-05 |
| 1101 m³/h | 1101 m3/h | 60 Hz · model 60 Hz; vacuum; at -250 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 1101Retrieved 2026-10-05 |
| 1055 m³/h | 1055 m3/h | 60 Hz · model 60 Hz; vacuum; at -300 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 1055Retrieved 2026-10-05 |
| 1006 m³/h | 1006 m3/h | 60 Hz · model 60 Hz; vacuum; at -350 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 1006Retrieved 2026-10-05 |
| 953 m³/h | 953 m3/h | 60 Hz · model 60 Hz; vacuum; at -400 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 953Retrieved 2026-10-05 |
Ultimate pressure · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Motor power · Sourced · 8 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 15.00 kW | 15 kW | 50 Hz · model 50 Hz; compression; at max. flow unspecified | Source · OEM_SOURCE different frequency Installed motor size: 15.00Retrieved 2026-10-05 |
| 22.00 kW | 22 kW | 50 Hz · model 50 Hz; compression; at Δp max 450 mbar unspecified | Source · OEM_SOURCE different frequency Installed motor size: 22.00Retrieved 2026-10-05 |
| 15.00 kW | 15 kW | 50 Hz · model 50 Hz; vacuum; at max. flow unspecified | Source · OEM_SOURCE different frequency Installed motor size: 15.00Retrieved 2026-10-05 |
| 18.50 kW | 18.5 kW | 50 Hz · model 50 Hz; vacuum; at Δp max 400 mbar unspecified | Source · OEM_SOURCE different frequency Installed motor size: 18.50Retrieved 2026-10-05 |
| 15.00 kW | 15 kW | 60 Hz · model 60 Hz; compression; at max. flow unspecified | Source · OEM_SOURCEInstalled motor size: 15.00Retrieved 2026-10-05 |
| 22.00 kW | 22 kW | 60 Hz · model 60 Hz; compression; at Δp max 350 mbar unspecified | Source · OEM_SOURCEInstalled motor size: 22.00Retrieved 2026-10-05 |
| 15.00 kW | 15 kW | 60 Hz · model 60 Hz; vacuum; at max. flow unspecified | Source · OEM_SOURCEInstalled motor size: 15.00Retrieved 2026-10-05 |
| 22.00 kW | 22 kW | 60 Hz · model 60 Hz; vacuum; at Δp max 400 mbar unspecified | Source · OEM_SOURCEInstalled motor size: 22.00Retrieved 2026-10-05 |
Speed · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Noise level · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Weight · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Dimensions · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Inlet connection · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Outlet connection · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Max. pressure · Sourced · 2 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 450 mbar | 450 mbar | 50 Hz · model 50 Hz; compression unspecified | Source · OEM_SOURCE different frequency Δp max (compression): 450Retrieved 2026-10-05 |
| 350 mbar | 350 mbar | 60 Hz · model 60 Hz; compression unspecified | Source · OEM_SOURCEΔp max (compression): 350Retrieved 2026-10-05 |
Max. vacuum · Sourced · 2 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 400 mbar | 400 mbar | 50 Hz · model 50 Hz; vacuum unspecified | Source · OEM_SOURCE different frequency Δp max (vacuum): 400Retrieved 2026-10-05 |
| 400 mbar | 400 mbar | 60 Hz · model 60 Hz; vacuum unspecified | Source · OEM_SOURCEΔp max (vacuum): 400Retrieved 2026-10-05 |
Operating-performance coverage
Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.
No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.
Document coverage
Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.
| Category | Model links | Family links | Public sources |
|---|---|---|---|
| Specifications | 1 | 0 |
|
| Performance curves / test data | 0 | 0 | Not collected |
| Operation / service manuals | 0 | 0 | Not collected |
| Parts documentation | 0 | 0 | Not collected |
| Drawings / dimensions | 0 | 0 | Not collected |
| Product / family literature | 1 | 0 |
|
| Other / unclassified | 0 | 0 | Not collected |