One model, connected records

FPZ → FPZ side channel blowers → e12 TD

Manufacturer model: e12 TD · OEM article / order number: Not collected · Equipment type: vacuum pump

Technology: Regenerative / Side Channel

Related applications: Material Handling, Pick + Place, Pneumatic Conveying, Vacuum Hold-Down
Related industries: Printing, Pulp + Paper, Woodworking + CNC

These are technology associations. Check the operating point and process requirements to establish suitability for this model.

Compare coverage across this family

Specifications and evidence

48 stored observations · 23 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.

The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.

Pumping speed · Sourced · 36 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
1046 m³/h1046 m3/h50 Hz · model
50 Hz; compression
unspecified
Source · OEM_SOURCE
different frequency
Max. flow: 1046
Retrieved 2026-10-05
1017 m³/h1017 m3/h50 Hz · model
50 Hz; compression; at +50 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 1017
Retrieved 2026-10-05
987 m³/h987 m3/h50 Hz · model
50 Hz; compression; at +100 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 987
Retrieved 2026-10-05
958 m³/h958 m3/h50 Hz · model
50 Hz; compression; at +150 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 958
Retrieved 2026-10-05
929 m³/h929 m3/h50 Hz · model
50 Hz; compression; at +200 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 929
Retrieved 2026-10-05
900 m³/h900 m3/h50 Hz · model
50 Hz; compression; at +250 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 900
Retrieved 2026-10-05
872 m³/h872 m3/h50 Hz · model
50 Hz; compression; at +300 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 872
Retrieved 2026-10-05
844 m³/h844 m3/h50 Hz · model
50 Hz; compression; at +350 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 844
Retrieved 2026-10-05
816 m³/h816 m3/h50 Hz · model
50 Hz; compression; at +400 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 816
Retrieved 2026-10-05
789 m³/h789 m3/h50 Hz · model
50 Hz; compression; at +450 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 789
Retrieved 2026-10-05
1046 m³/h1046 m3/h50 Hz · model
50 Hz; vacuum
unspecified
Source · OEM_SOURCE
different frequency
Max. flow: 1046
Retrieved 2026-10-05
1024 m³/h1024 m3/h50 Hz · model
50 Hz; vacuum; at -50 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 1024
Retrieved 2026-10-05
991 m³/h991 m3/h50 Hz · model
50 Hz; vacuum; at -100 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 991
Retrieved 2026-10-05
953 m³/h953 m3/h50 Hz · model
50 Hz; vacuum; at -150 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 953
Retrieved 2026-10-05
910 m³/h910 m3/h50 Hz · model
50 Hz; vacuum; at -200 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 910
Retrieved 2026-10-05
862 m³/h862 m3/h50 Hz · model
50 Hz; vacuum; at -250 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 862
Retrieved 2026-10-05
808 m³/h808 m3/h50 Hz · model
50 Hz; vacuum; at -300 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 808
Retrieved 2026-10-05
750 m³/h750 m3/h50 Hz · model
50 Hz; vacuum; at -350 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 750
Retrieved 2026-10-05
687 m³/h687 m3/h50 Hz · model
50 Hz; vacuum; at -400 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 687
Retrieved 2026-10-05
1263 m³/h1263 m3/h60 Hz · model
60 Hz; compression
unspecified
Source · OEM_SOURCE
Max. flow: 1263
Retrieved 2026-10-05
1237 m³/h1237 m3/h60 Hz · model
60 Hz; compression; at +50 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 1237
Retrieved 2026-10-05
1212 m³/h1212 m3/h60 Hz · model
60 Hz; compression; at +100 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 1212
Retrieved 2026-10-05
1186 m³/h1186 m3/h60 Hz · model
60 Hz; compression; at +150 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 1186
Retrieved 2026-10-05
1161 m³/h1161 m3/h60 Hz · model
60 Hz; compression; at +200 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 1161
Retrieved 2026-10-05
1136 m³/h1136 m3/h60 Hz · model
60 Hz; compression; at +250 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 1136
Retrieved 2026-10-05
1112 m³/h1112 m3/h60 Hz · model
60 Hz; compression; at +300 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 1112
Retrieved 2026-10-05
1087 m³/h1087 m3/h60 Hz · model
60 Hz; compression; at +350 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 1087
Retrieved 2026-10-05
1263 m³/h1263 m3/h60 Hz · model
60 Hz; vacuum
unspecified
Source · OEM_SOURCE
Max. flow: 1263
Retrieved 2026-10-05
1244 m³/h1244 m3/h60 Hz · model
60 Hz; vacuum; at -50 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 1244
Retrieved 2026-10-05
1214 m³/h1214 m3/h60 Hz · model
60 Hz; vacuum; at -100 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 1214
Retrieved 2026-10-05
1180 m³/h1180 m3/h60 Hz · model
60 Hz; vacuum; at -150 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 1180
Retrieved 2026-10-05
1142 m³/h1142 m3/h60 Hz · model
60 Hz; vacuum; at -200 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 1142
Retrieved 2026-10-05
1101 m³/h1101 m3/h60 Hz · model
60 Hz; vacuum; at -250 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 1101
Retrieved 2026-10-05
1055 m³/h1055 m3/h60 Hz · model
60 Hz; vacuum; at -300 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 1055
Retrieved 2026-10-05
1006 m³/h1006 m3/h60 Hz · model
60 Hz; vacuum; at -350 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 1006
Retrieved 2026-10-05
953 m³/h953 m3/h60 Hz · model
60 Hz; vacuum; at -400 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 953
Retrieved 2026-10-05
Ultimate pressure · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Motor power · Sourced · 8 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
15.00 kW15 kW50 Hz · model
50 Hz; compression; at max. flow
unspecified
Source · OEM_SOURCE
different frequency
Installed motor size: 15.00
Retrieved 2026-10-05
22.00 kW22 kW50 Hz · model
50 Hz; compression; at Δp max 450 mbar
unspecified
Source · OEM_SOURCE
different frequency
Installed motor size: 22.00
Retrieved 2026-10-05
15.00 kW15 kW50 Hz · model
50 Hz; vacuum; at max. flow
unspecified
Source · OEM_SOURCE
different frequency
Installed motor size: 15.00
Retrieved 2026-10-05
18.50 kW18.5 kW50 Hz · model
50 Hz; vacuum; at Δp max 400 mbar
unspecified
Source · OEM_SOURCE
different frequency
Installed motor size: 18.50
Retrieved 2026-10-05
15.00 kW15 kW60 Hz · model
60 Hz; compression; at max. flow
unspecified
Source · OEM_SOURCE
Installed motor size: 15.00
Retrieved 2026-10-05
22.00 kW22 kW60 Hz · model
60 Hz; compression; at Δp max 350 mbar
unspecified
Source · OEM_SOURCE
Installed motor size: 22.00
Retrieved 2026-10-05
15.00 kW15 kW60 Hz · model
60 Hz; vacuum; at max. flow
unspecified
Source · OEM_SOURCE
Installed motor size: 15.00
Retrieved 2026-10-05
22.00 kW22 kW60 Hz · model
60 Hz; vacuum; at Δp max 400 mbar
unspecified
Source · OEM_SOURCE
Installed motor size: 22.00
Retrieved 2026-10-05
Speed · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Noise level · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Weight · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Dimensions · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Inlet connection · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Outlet connection · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Max. pressure · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
450 mbar450 mbar50 Hz · model
50 Hz; compression
unspecified
Source · OEM_SOURCE
different frequency
Δp max (compression): 450
Retrieved 2026-10-05
350 mbar350 mbar60 Hz · model
60 Hz; compression
unspecified
Source · OEM_SOURCE
Δp max (compression): 350
Retrieved 2026-10-05
Max. vacuum · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
400 mbar400 mbar50 Hz · model
50 Hz; vacuum
unspecified
Source · OEM_SOURCE
different frequency
Δp max (vacuum): 400
Retrieved 2026-10-05
400 mbar400 mbar60 Hz · model
60 Hz; vacuum
unspecified
Source · OEM_SOURCE
Δp max (vacuum): 400
Retrieved 2026-10-05

Operating-performance coverage

Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.

No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.

Document coverage

Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.

CategoryModel linksFamily linksPublic sources
Specifications10
Performance curves / test data00Not collected
Operation / service manuals00Not collected
Parts documentation00Not collected
Drawings / dimensions00Not collected
Product / family literature10
Other / unclassified00Not collected