Data coverage & sources
The stored record for FPZ e12 TS: specifications, configurations, documents, sources, and gaps.
One model, connected records
FPZ → FPZ side channel blowers → e12 TS
Manufacturer model: e12 TS · OEM article / order number: Not collected · Equipment type: vacuum pump
Technology: Regenerative / Side Channel
Related applications: Material Handling, Pick + Place, Pneumatic Conveying, Vacuum Hold-Down
Related industries: Printing, Pulp + Paper, Woodworking + CNC
These are technology associations. Check the operating point and process requirements to establish suitability for this model.
Compare coverage across this familySpecifications and evidence
33 stored observations · 15 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.
The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.
Pumping speed · Sourced · 21 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 2106 m³/h | 2106 m3/h | 50 Hz · model 50 Hz; compression unspecified | Source · OEM_SOURCE different frequency Max. flow: 2106Retrieved 2026-10-05 |
| 1966 m³/h | 1966 m3/h | 50 Hz · model 50 Hz; compression; at +50 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 1966Retrieved 2026-10-05 |
| 1834 m³/h | 1834 m3/h | 50 Hz · model 50 Hz; compression; at +100 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 1834Retrieved 2026-10-05 |
| 1711 m³/h | 1711 m3/h | 50 Hz · model 50 Hz; compression; at +150 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 1711Retrieved 2026-10-05 |
| 1596 m³/h | 1596 m3/h | 50 Hz · model 50 Hz; compression; at +200 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 1596Retrieved 2026-10-05 |
| 1489 m³/h | 1489 m3/h | 50 Hz · model 50 Hz; compression; at +250 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 1489Retrieved 2026-10-05 |
| 2106 m³/h | 2106 m3/h | 50 Hz · model 50 Hz; vacuum unspecified | Source · OEM_SOURCE different frequency Max. flow: 2106Retrieved 2026-10-05 |
| 1958 m³/h | 1958 m3/h | 50 Hz · model 50 Hz; vacuum; at -50 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 1958Retrieved 2026-10-05 |
| 1806 m³/h | 1806 m3/h | 50 Hz · model 50 Hz; vacuum; at -100 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 1806Retrieved 2026-10-05 |
| 1646 m³/h | 1646 m3/h | 50 Hz · model 50 Hz; vacuum; at -150 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 1646Retrieved 2026-10-05 |
| 1478 m³/h | 1478 m3/h | 50 Hz · model 50 Hz; vacuum; at -200 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 1478Retrieved 2026-10-05 |
| 1302 m³/h | 1302 m3/h | 50 Hz · model 50 Hz; vacuum; at -250 hPa (mbar) unspecified | Source · OEM_SOURCE different frequency Flow: 1302Retrieved 2026-10-05 |
| 2542 m³/h | 2542 m3/h | 60 Hz · model 60 Hz; compression unspecified | Source · OEM_SOURCEMax. flow: 2542Retrieved 2026-10-05 |
| 2420 m³/h | 2420 m3/h | 60 Hz · model 60 Hz; compression; at +50 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 2420Retrieved 2026-10-05 |
| 2304 m³/h | 2304 m3/h | 60 Hz · model 60 Hz; compression; at +100 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 2304Retrieved 2026-10-05 |
| 2193 m³/h | 2193 m3/h | 60 Hz · model 60 Hz; compression; at +150 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 2193Retrieved 2026-10-05 |
| 2542 m³/h | 2542 m3/h | 60 Hz · model 60 Hz; vacuum unspecified | Source · OEM_SOURCEMax. flow: 2542Retrieved 2026-10-05 |
| 2401 m³/h | 2401 m3/h | 60 Hz · model 60 Hz; vacuum; at -50 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 2401Retrieved 2026-10-05 |
| 2258 m³/h | 2258 m3/h | 60 Hz · model 60 Hz; vacuum; at -100 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 2258Retrieved 2026-10-05 |
| 2109 m³/h | 2109 m3/h | 60 Hz · model 60 Hz; vacuum; at -150 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 2109Retrieved 2026-10-05 |
| 1954 m³/h | 1954 m3/h | 60 Hz · model 60 Hz; vacuum; at -200 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 1954Retrieved 2026-10-05 |
Ultimate pressure · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Motor power · Sourced · 8 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 15.00 kW | 15 kW | 50 Hz · model 50 Hz; compression; at max. flow unspecified | Source · OEM_SOURCE different frequency Installed motor size: 15.00Retrieved 2026-10-05 |
| 22.00 kW | 22 kW | 50 Hz · model 50 Hz; compression; at Δp max 250 mbar unspecified | Source · OEM_SOURCE different frequency Installed motor size: 22.00Retrieved 2026-10-05 |
| 15.00 kW | 15 kW | 50 Hz · model 50 Hz; vacuum; at max. flow unspecified | Source · OEM_SOURCE different frequency Installed motor size: 15.00Retrieved 2026-10-05 |
| 22.00 kW | 22 kW | 50 Hz · model 50 Hz; vacuum; at Δp max 250 mbar unspecified | Source · OEM_SOURCE different frequency Installed motor size: 22.00Retrieved 2026-10-05 |
| 15.00 kW | 15 kW | 60 Hz · model 60 Hz; compression; at max. flow unspecified | Source · OEM_SOURCEInstalled motor size: 15.00Retrieved 2026-10-05 |
| 22.00 kW | 22 kW | 60 Hz · model 60 Hz; compression; at Δp max 175 mbar unspecified | Source · OEM_SOURCEInstalled motor size: 22.00Retrieved 2026-10-05 |
| 15.00 kW | 15 kW | 60 Hz · model 60 Hz; vacuum; at max. flow unspecified | Source · OEM_SOURCEInstalled motor size: 15.00Retrieved 2026-10-05 |
| 22.00 kW | 22 kW | 60 Hz · model 60 Hz; vacuum; at Δp max 200 mbar unspecified | Source · OEM_SOURCEInstalled motor size: 22.00Retrieved 2026-10-05 |
Speed · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Noise level · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Weight · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Dimensions · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Inlet connection · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Outlet connection · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Max. pressure · Sourced · 2 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 250 mbar | 250 mbar | 50 Hz · model 50 Hz; compression unspecified | Source · OEM_SOURCE different frequency Δp max (compression): 250Retrieved 2026-10-05 |
| 175 mbar | 175 mbar | 60 Hz · model 60 Hz; compression unspecified | Source · OEM_SOURCEΔp max (compression): 175Retrieved 2026-10-05 |
Max. vacuum · Sourced · 2 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 250 mbar | 250 mbar | 50 Hz · model 50 Hz; vacuum unspecified | Source · OEM_SOURCE different frequency Δp max (vacuum): 250Retrieved 2026-10-05 |
| 200 mbar | 200 mbar | 60 Hz · model 60 Hz; vacuum unspecified | Source · OEM_SOURCEΔp max (vacuum): 200Retrieved 2026-10-05 |
Operating-performance coverage
Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.
No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.
Document coverage
Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.
| Category | Model links | Family links | Public sources |
|---|---|---|---|
| Specifications | 1 | 0 |
|
| Performance curves / test data | 0 | 0 | Not collected |
| Operation / service manuals | 0 | 0 | Not collected |
| Parts documentation | 0 | 0 | Not collected |
| Drawings / dimensions | 0 | 0 | Not collected |
| Product / family literature | 1 | 0 |
|
| Other / unclassified | 0 | 0 | Not collected |