Find equipmentComparePartsManufacturersTechnologiesIndustriesApplicationsAsset trackingMy equipmentTalk to a specialist

Data coverage & sources

The stored record for FPZ e12 TS: specifications, configurations, documents, sources, and gaps.

One model, connected records

FPZ → FPZ side channel blowers → e12 TS

Manufacturer model: e12 TS · OEM article / order number: Not collected · Equipment type: vacuum pump

Technology: Regenerative / Side Channel

Related applications: Material Handling, Pick + Place, Pneumatic Conveying, Vacuum Hold-Down
Related industries: Printing, Pulp + Paper, Woodworking + CNC

These are technology associations. Check the operating point and process requirements to establish suitability for this model.

Compare coverage across this family

Specifications and evidence

33 stored observations · 15 pass the source policy at 60 Hz. Individual ratings do not establish flow at a requested pressure.

The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.

Pumping speed · Sourced · 21 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
2106 m³/h2106 m3/h50 Hz · model
50 Hz; compression
unspecified
Source · OEM_SOURCE
different frequency
Max. flow: 2106
Retrieved 2026-10-05
1966 m³/h1966 m3/h50 Hz · model
50 Hz; compression; at +50 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 1966
Retrieved 2026-10-05
1834 m³/h1834 m3/h50 Hz · model
50 Hz; compression; at +100 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 1834
Retrieved 2026-10-05
1711 m³/h1711 m3/h50 Hz · model
50 Hz; compression; at +150 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 1711
Retrieved 2026-10-05
1596 m³/h1596 m3/h50 Hz · model
50 Hz; compression; at +200 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 1596
Retrieved 2026-10-05
1489 m³/h1489 m3/h50 Hz · model
50 Hz; compression; at +250 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 1489
Retrieved 2026-10-05
2106 m³/h2106 m3/h50 Hz · model
50 Hz; vacuum
unspecified
Source · OEM_SOURCE
different frequency
Max. flow: 2106
Retrieved 2026-10-05
1958 m³/h1958 m3/h50 Hz · model
50 Hz; vacuum; at -50 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 1958
Retrieved 2026-10-05
1806 m³/h1806 m3/h50 Hz · model
50 Hz; vacuum; at -100 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 1806
Retrieved 2026-10-05
1646 m³/h1646 m3/h50 Hz · model
50 Hz; vacuum; at -150 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 1646
Retrieved 2026-10-05
1478 m³/h1478 m3/h50 Hz · model
50 Hz; vacuum; at -200 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 1478
Retrieved 2026-10-05
1302 m³/h1302 m3/h50 Hz · model
50 Hz; vacuum; at -250 hPa (mbar)
unspecified
Source · OEM_SOURCE
different frequency
Flow: 1302
Retrieved 2026-10-05
2542 m³/h2542 m3/h60 Hz · model
60 Hz; compression
unspecified
Source · OEM_SOURCE
Max. flow: 2542
Retrieved 2026-10-05
2420 m³/h2420 m3/h60 Hz · model
60 Hz; compression; at +50 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 2420
Retrieved 2026-10-05
2304 m³/h2304 m3/h60 Hz · model
60 Hz; compression; at +100 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 2304
Retrieved 2026-10-05
2193 m³/h2193 m3/h60 Hz · model
60 Hz; compression; at +150 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 2193
Retrieved 2026-10-05
2542 m³/h2542 m3/h60 Hz · model
60 Hz; vacuum
unspecified
Source · OEM_SOURCE
Max. flow: 2542
Retrieved 2026-10-05
2401 m³/h2401 m3/h60 Hz · model
60 Hz; vacuum; at -50 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 2401
Retrieved 2026-10-05
2258 m³/h2258 m3/h60 Hz · model
60 Hz; vacuum; at -100 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 2258
Retrieved 2026-10-05
2109 m³/h2109 m3/h60 Hz · model
60 Hz; vacuum; at -150 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 2109
Retrieved 2026-10-05
1954 m³/h1954 m3/h60 Hz · model
60 Hz; vacuum; at -200 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 1954
Retrieved 2026-10-05
Ultimate pressure · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Motor power · Sourced · 8 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
15.00 kW15 kW50 Hz · model
50 Hz; compression; at max. flow
unspecified
Source · OEM_SOURCE
different frequency
Installed motor size: 15.00
Retrieved 2026-10-05
22.00 kW22 kW50 Hz · model
50 Hz; compression; at Δp max 250 mbar
unspecified
Source · OEM_SOURCE
different frequency
Installed motor size: 22.00
Retrieved 2026-10-05
15.00 kW15 kW50 Hz · model
50 Hz; vacuum; at max. flow
unspecified
Source · OEM_SOURCE
different frequency
Installed motor size: 15.00
Retrieved 2026-10-05
22.00 kW22 kW50 Hz · model
50 Hz; vacuum; at Δp max 250 mbar
unspecified
Source · OEM_SOURCE
different frequency
Installed motor size: 22.00
Retrieved 2026-10-05
15.00 kW15 kW60 Hz · model
60 Hz; compression; at max. flow
unspecified
Source · OEM_SOURCE
Installed motor size: 15.00
Retrieved 2026-10-05
22.00 kW22 kW60 Hz · model
60 Hz; compression; at Δp max 175 mbar
unspecified
Source · OEM_SOURCE
Installed motor size: 22.00
Retrieved 2026-10-05
15.00 kW15 kW60 Hz · model
60 Hz; vacuum; at max. flow
unspecified
Source · OEM_SOURCE
Installed motor size: 15.00
Retrieved 2026-10-05
22.00 kW22 kW60 Hz · model
60 Hz; vacuum; at Δp max 200 mbar
unspecified
Source · OEM_SOURCE
Installed motor size: 22.00
Retrieved 2026-10-05
Speed · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Noise level · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Weight · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Dimensions · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Inlet connection · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Outlet connection · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Max. pressure · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
250 mbar250 mbar50 Hz · model
50 Hz; compression
unspecified
Source · OEM_SOURCE
different frequency
Δp max (compression): 250
Retrieved 2026-10-05
175 mbar175 mbar60 Hz · model
60 Hz; compression
unspecified
Source · OEM_SOURCE
Δp max (compression): 175
Retrieved 2026-10-05
Max. vacuum · Sourced · 2 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
250 mbar250 mbar50 Hz · model
50 Hz; vacuum
unspecified
Source · OEM_SOURCE
different frequency
Δp max (vacuum): 250
Retrieved 2026-10-05
200 mbar200 mbar60 Hz · model
60 Hz; vacuum
unspecified
Source · OEM_SOURCE
Δp max (vacuum): 200
Retrieved 2026-10-05

Operating-performance coverage

Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.

No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.

Document coverage

Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.

CategoryModel linksFamily linksPublic sources
Specifications10
Performance curves / test data00Not collected
Operation / service manuals00Not collected
Parts documentation00Not collected
Drawings / dimensions00Not collected
Product / family literature10
Other / unclassified00Not collected