Data coverage & sources
The stored record for FPZ K05-66 TS: specifications, configurations, documents, sources, and gaps.
One model, connected records
FPZ → FPZ side channel blowers → K05-66 TS
Manufacturer model: K05-66 TS · OEM article / order number: Not collected · Equipment type: vacuum pump
Technology: Regenerative / Side Channel
Related applications: Material Handling, Pick + Place, Pneumatic Conveying, Vacuum Hold-Down
Related industries: Printing, Pulp + Paper, Woodworking + CNC
These are technology associations. Check the operating point and process requirements to establish suitability for this model.
Compare coverage across this familySpecifications and evidence
16 stored observations · 16 pass the source policy at 50 Hz. Individual ratings do not establish flow at a requested pressure.
The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.
Pumping speed · Sourced · 10 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 334.0 m³/h | 334 m3/h | 50 Hz · model 50 Hz; compression unspecified | Source · OEM_SOURCEMax. flow: 334.0Retrieved 2026-10-05 |
| 315.3 m³/h | 315.3 m3/h | 50 Hz · model 50 Hz; compression; at +50 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 315.3Retrieved 2026-10-05 |
| 286.3 m³/h | 286.3 m3/h | 50 Hz · model 50 Hz; compression; at +100 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 286.3Retrieved 2026-10-05 |
| 247.1 m³/h | 247.1 m3/h | 50 Hz · model 50 Hz; compression; at +150 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 247.1Retrieved 2026-10-05 |
| 197.8 m³/h | 197.8 m3/h | 50 Hz · model 50 Hz; compression; at +200 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 197.8Retrieved 2026-10-05 |
| 334.0 m³/h | 334 m3/h | 50 Hz · model 50 Hz; vacuum unspecified | Source · OEM_SOURCEMax. flow: 334.0Retrieved 2026-10-05 |
| 318.6 m³/h | 318.6 m3/h | 50 Hz · model 50 Hz; vacuum; at -50 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 318.6Retrieved 2026-10-05 |
| 281.6 m³/h | 281.6 m3/h | 50 Hz · model 50 Hz; vacuum; at -100 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 281.6Retrieved 2026-10-05 |
| 223.0 m³/h | 223 m3/h | 50 Hz · model 50 Hz; vacuum; at -150 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 223.0Retrieved 2026-10-05 |
| 142.9 m³/h | 142.9 m3/h | 50 Hz · model 50 Hz; vacuum; at -200 hPa (mbar) unspecified | Source · OEM_SOURCEFlow: 142.9Retrieved 2026-10-05 |
Ultimate pressure · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Motor power · Sourced · 4 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 4.00 kW | 4 kW | 50 Hz · model 50 Hz; compression; at max. flow unspecified | Source · OEM_SOURCEInstalled motor size: 4.00Retrieved 2026-10-05 |
| 4.00 kW | 4 kW | 50 Hz · model 50 Hz; compression; at Δp max 235 mbar unspecified | Source · OEM_SOURCEInstalled motor size: 4.00Retrieved 2026-10-05 |
| 4.00 kW | 4 kW | 50 Hz · model 50 Hz; vacuum; at max. flow unspecified | Source · OEM_SOURCEInstalled motor size: 4.00Retrieved 2026-10-05 |
| 4.00 kW | 4 kW | 50 Hz · model 50 Hz; vacuum; at Δp max 210 mbar unspecified | Source · OEM_SOURCEInstalled motor size: 4.00Retrieved 2026-10-05 |
Speed · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Noise level · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Weight · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Dimensions · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Inlet connection · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Outlet connection · Not collected · 0 observations / 0 sources
No stored observation. A family brochure or a separate maximum rating does not fill this field.
Max. pressure · Sourced · 1 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 235 mbar | 235 mbar | 50 Hz · model 50 Hz; compression unspecified | Source · OEM_SOURCEΔp max (compression): 235Retrieved 2026-10-05 |
Max. vacuum · Sourced · 1 observations / 1 sources
| As published | Normalized | Configuration / scope | Source / status |
|---|---|---|---|
| 210 mbar | 210 mbar | 50 Hz · model 50 Hz; vacuum unspecified | Source · OEM_SOURCEΔp max (vacuum): 210Retrieved 2026-10-05 |
Operating-performance coverage
Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.
No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.
Document coverage
Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.
| Category | Model links | Family links | Public sources |
|---|---|---|---|
| Specifications | 1 | 0 |
|
| Performance curves / test data | 0 | 0 | Not collected |
| Operation / service manuals | 0 | 0 | Not collected |
| Parts documentation | 0 | 0 | Not collected |
| Drawings / dimensions | 0 | 0 | Not collected |
| Product / family literature | 1 | 0 |
|
| Other / unclassified | 0 | 0 | Not collected |