Find equipmentComparePartsManufacturersTechnologiesIndustriesApplicationsAsset trackingMy equipmentTalk to a specialist

Data coverage & sources

The stored record for FPZ K05-66 TS: specifications, configurations, documents, sources, and gaps.

One model, connected records

FPZ → FPZ side channel blowers → K05-66 TS

Manufacturer model: K05-66 TS · OEM article / order number: Not collected · Equipment type: vacuum pump

Technology: Regenerative / Side Channel

Related applications: Material Handling, Pick + Place, Pneumatic Conveying, Vacuum Hold-Down
Related industries: Printing, Pulp + Paper, Woodworking + CNC

These are technology associations. Check the operating point and process requirements to establish suitability for this model.

Compare coverage across this family

Specifications and evidence

16 stored observations · 16 pass the source policy at 50 Hz. Individual ratings do not establish flow at a requested pressure.

The collection checklist follows the equipment type. Additional attributes are retained. “Not collected” means the database has no observation for that field.

Pumping speed · Sourced · 10 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
334.0 m³/h334 m3/h50 Hz · model
50 Hz; compression
unspecified
Source · OEM_SOURCE
Max. flow: 334.0
Retrieved 2026-10-05
315.3 m³/h315.3 m3/h50 Hz · model
50 Hz; compression; at +50 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 315.3
Retrieved 2026-10-05
286.3 m³/h286.3 m3/h50 Hz · model
50 Hz; compression; at +100 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 286.3
Retrieved 2026-10-05
247.1 m³/h247.1 m3/h50 Hz · model
50 Hz; compression; at +150 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 247.1
Retrieved 2026-10-05
197.8 m³/h197.8 m3/h50 Hz · model
50 Hz; compression; at +200 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 197.8
Retrieved 2026-10-05
334.0 m³/h334 m3/h50 Hz · model
50 Hz; vacuum
unspecified
Source · OEM_SOURCE
Max. flow: 334.0
Retrieved 2026-10-05
318.6 m³/h318.6 m3/h50 Hz · model
50 Hz; vacuum; at -50 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 318.6
Retrieved 2026-10-05
281.6 m³/h281.6 m3/h50 Hz · model
50 Hz; vacuum; at -100 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 281.6
Retrieved 2026-10-05
223.0 m³/h223 m3/h50 Hz · model
50 Hz; vacuum; at -150 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 223.0
Retrieved 2026-10-05
142.9 m³/h142.9 m3/h50 Hz · model
50 Hz; vacuum; at -200 hPa (mbar)
unspecified
Source · OEM_SOURCE
Flow: 142.9
Retrieved 2026-10-05
Ultimate pressure · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Motor power · Sourced · 4 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
4.00 kW4 kW50 Hz · model
50 Hz; compression; at max. flow
unspecified
Source · OEM_SOURCE
Installed motor size: 4.00
Retrieved 2026-10-05
4.00 kW4 kW50 Hz · model
50 Hz; compression; at Δp max 235 mbar
unspecified
Source · OEM_SOURCE
Installed motor size: 4.00
Retrieved 2026-10-05
4.00 kW4 kW50 Hz · model
50 Hz; vacuum; at max. flow
unspecified
Source · OEM_SOURCE
Installed motor size: 4.00
Retrieved 2026-10-05
4.00 kW4 kW50 Hz · model
50 Hz; vacuum; at Δp max 210 mbar
unspecified
Source · OEM_SOURCE
Installed motor size: 4.00
Retrieved 2026-10-05
Speed · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Noise level · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Weight · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Dimensions · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Inlet connection · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Outlet connection · Not collected · 0 observations / 0 sources

No stored observation. A family brochure or a separate maximum rating does not fill this field.

Max. pressure · Sourced · 1 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
235 mbar235 mbar50 Hz · model
50 Hz; compression
unspecified
Source · OEM_SOURCE
Δp max (compression): 235
Retrieved 2026-10-05
Max. vacuum · Sourced · 1 observations / 1 sources
As publishedNormalizedConfiguration / scopeSource / status
210 mbar210 mbar50 Hz · model
50 Hz; vacuum
unspecified
Source · OEM_SOURCE
Δp max (vacuum): 210
Retrieved 2026-10-05

Operating-performance coverage

Each row keeps its own configuration and relationship. Pending points are stored for review and excluded from shopper comparisons.

No versioned performance dataset has been collected for this model. Stored legacy points: 0; each retains its existing evidence status.

Document coverage

Categories follow recorded document types and linked extracted data. One document can appear in several categories. Family documents remain shared references; extraction does not imply approval.

CategoryModel linksFamily linksPublic sources
Specifications10
Performance curves / test data00Not collected
Operation / service manuals00Not collected
Parts documentation00Not collected
Drawings / dimensions00Not collected
Product / family literature10
Other / unclassified00Not collected